Case Report
2023
:2;
100126
doi:
10.1016/j.jorep.2022.100126

Translate:

A simple treatment strategy for peri-implant fracture of the humerus: Report of two cases

Author affiliations
Dept of Orthopaedics, Sri SathyaSai Institute of Higher Medical Sciences, Prashanthigram, Puttaparthi, Andhra Pradesh, 515134, India
Article History
Corresponding author(s)

∗Corresponding author: Koushik Narayan Subramanyam. koushik.n@sssihms.org.in

Article tools · PDF & citations

Abstract

Abstract

Non-prosthetic peri-implant fractures and under reported entities and their optimal management strategies are uncertain.

We present two cases of peri-implant fractures of distal humerus with long dynamic compression plate in situ. We report for the first time a strategy of implant retention, open reduction with small incision, minimal internal fixation with K-wires and supplementary fixation with bilateral external fixator using Joshi's External Stabilizing System (JESS). Both fractures showed signs of union at three months from surgery. The fixators were removed at four months under sedation and patients were advised aggressive active mobilisation of the elbow. This resulted in sound union of the fracture with preservation of elbow motion without any complications.

We recommend this method, as it is a simple, safe, effective and reproducible technique for management of peri-implant fractures of the humerus.

Keywords

  • Peri-implant fracture
  • Humerus
  • JESS
  • External fixator
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Non-prosthetic peri-implant fractures are the ones that occur near a non-prosthetic implant like screws, plates or intramedullary nails. Previously these entities are reported along with the commoner periprosthetic fractures that occur around joint replacement implants. These fractures are quite under-reported and literature pertaining to them is sparse. Of late, it has been identified as a separate entity with a separate classification system.1 Management of these injuries are challenging and not well described in literature.1

2

2 Description of cases

We present two similar cases of peri-implant fractures of the humerus with dynamic compression plate in situ. As an alternative to the standard surgical option of implant removal and re-plating, we devised a simpler surgical strategy of implant retention, open osteosynthesis and external fixation with Joshi's External Stabilizing System (JESS), which is for the first time being reported.

Case 1 (Fig. 1A–D): A 28yearold male patient with history of posterior plate fixation of left humerus 11 months back had a second fall and sustained peri-implant fracture of distal humerus. The patient presented with painful abnormal mobility of distal humerus with normal skin condition and no distal neurovascular deficits.

A: Preoperative radiographs of Case 1 Fig. 1B: Immediate post-operative radiographs of Case 1 Fig. 1C: Clinical photographs of the Case 1 with JESS fixator in situ Fig. 1D: Follow up-radiographs and functional outcome of Case 1 at one year.
Fig. 1 A: Preoperative radiographs of Case 1 Fig. 1B: Immediate post-operative radiographs of Case 1 Fig. 1C: Clinical photographs of the Case 1 with JESS fixator in situ Fig. 1D: Follow up-radiographs and functional outcome of Case 1 at one year.

Case 2 (Fig. 2A–C): A 46 year old male patient presented with similar history and findings. The index surgery performed was plate fixation of left humerus through posterior approach 18 months before. Currently the patient had a fall that resulted in peri-implant fracture.

A: Preoperative radiographs of Case 2 Fig. 2B: Immediate post-operative radiographs of Case 2 Fig. 2C: Follow up-radiographs and functional outcome of Case 2 at one year.
Fig. 2 A: Preoperative radiographs of Case 2 Fig. 2B: Immediate post-operative radiographs of Case 2 Fig. 2C: Follow up-radiographs and functional outcome of Case 2 at one year.

Anteroposterior and Lateral radiographs revealed distal peri-implant fracture of the distal humerus in both cases. In either case the fracture communicated through the most distal screw. The primary diaphyseal fracture of humerus had completely healed in both patients.

Treatment strategy and Surgical Technique: The standard treatment for this injury would have been implant removal and re-fixation with a longer plate. We did not go for it considering the chances of extensive surgery and complications (radial nerve injury in particular). We devised a less invasive surgery, implant retention, limited internal fixation and external fixation. There are a few reports of management of distal humerus fractures with JESS (external fixator).2,3 We decided to explore this option to strengthen our limited internal fixation to promote early elbow mobilisation.

Both fractures were explored through the original triceps-splitting approach. The screw through which the fracture occurred was removed. Fracture ends were freshened and approximated. Fractures was fixed with two K-wires and found to be stable. The wound was closed. The fractures were further stabilised with JESS fixator components. The number of wires and their placement were decided on the fracture pattern (stability needed) and availability of safe windows. Special care was taken to avoid neurovascular injury during wire placements.

The first patient had two transosseous wires on either side of the fracture, one half pin on the distal fragment and two half pins on the proximal fragment. The second patient had two transosseous wires on either side of the fracture and one-half pin on the proximal fragment. The external fixator assembly was bilateral with two rods each on medial and lateral sides. The fractures were fixed in compression as the beta clamps were being tightened to secure the rods to the wires.

Both patients were advised use of broad arm sling and aggressive intermittent mobilisation of the elbow. Both fractures showed signs of union (as evidenced by bony continuity of three cortices in two views) at three months from surgery. For safety, the fixators were retained for another month and both fixators were removed at four months under sedation and patients were advised aggressive active mobilisation of the elbow.

Results: The fractures in both patients uneventfully united. At one year follow-up, there was no incidence of refracture and both patients exhibited complete range of motion of the elbow.

3

3 Discussion

Non-prosthetic peri-implant fractures are not uncommon occurrences, but management strategies are sparingly reported.1 Previous studies reporting upper limb peri-implant fractures felt that removal of the original implant and leaving the original fracture unfixed leads to high incidence of refracture.4 The largest series on peri-implant fractures reports 20% complication rates in patients managed surgically.1 The vast majority of these complications are refractures and non-unions.1

We differed from the standard approach of implant removal and re-plating due to following reasons. The plates in situ were already long plates and their removal would require extensive surgical dissection. To prevent refracture, it would need even longer plates that would lead to significant soft tissue stripping. There was definite risk of radial nerve injury due to posterior location of the plate, post-operative fibrosis and requirement to dissect the nerve throughout its course in posterior compartment. We also felt that re-fixation could be challenging considering the number of previous screw tracts in the bone that would compromise on the screw purchase if we used them or act as stress-raisers if we did not use them. We also felt that the distal fragment would be too small to achieve optimum screw purchase on the distal fragment. This would definitely need dual plating with more soft tissue stripping and all the technical issues associated with this. Though dual plating reduces the chances of secondary loss of reduction, it can cause bone splintering during application, soft tissue complications requiring removal and late peri-implant fractures5 In peri-implant fractures of the humerus, implant retention and addition of a second plate has been already described1 but we did not adopt this strategy due to the complications of dual plating mentioned above.

Implant retention and fracture fixation with lag screws was an option we entertained pre-operatively. But during surgery, we recognised that the bone thickness was less and attempt to apply lag screws would inadvertently cause splintering. We had decided any way to use the external fixator and not just cast immobilisation that would result in stiffness of the elbow. We found that K-wires gave reasonable intraoperative stability and the effect of the muscle forces and gravity to displace the fracture could be neutralised with external fixator and aggressive mobilisation of the elbow so as to preserve its motion. To our knowledge, this strategy of minimal internal fixation and supplementary external fixation is being reported for the first time in peri-implant fractures of the humerus. Because it worked well in two cases, we believe that it is a simple, effective, safe and reproducible strategy in the management of non-prosthetic peri-implant fractures of the humerus.

4

4 Conclusion

We conclude that implant retention, open reduction with small incision, minimal internal fixation with K-wires and supplementary fixation with bilateral external fixator leads to sound union of fracture in non-prosthetic peri-implant fractures of the humerus, avoiding possible complications. Preservation of elbow range of motion is of great importance and is facilitated by this strategy.

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Patients consent

The authors certify that they have obtained all appropriate patient consent forms. In the form the patients have given their consent for images and other clinical information to be reported in the journal. The patients understands that their name and initials will not be published and due efforts will be made to conceal their identity, but anonymity cannot be guaranteed.

Authors contribution

KNS conceptualised the treatment strategy. KNS and AVM performed the surgery on both patients. All four authors were equally involved in collection of data and evaluation of follow-up pertaining to both patients and in the writing of the manuscript.

References

  1. , , , , , . Singapore Orthopaedic Research CollaborativE (SORCE).Non-prosthetic peri-implant fractures: classification, management and outcomes. Arch Orthop Trauma Surg. 2018;138(6):791-802.
    [Google Scholar]
  2. , , , . Management of comminuted distal humerus fracture by minimal internal fixation and external fixation in the form of Joshi's external stabilization System in older individual: a prospective study. Int J Sci Stud. 2016;4:34-38.
    [Google Scholar]
  3. , , , , , , . Management of supracondylar fracture of humerus with JESS in adults. JSciSociety. 2015;42:1.
    [Google Scholar]
  4. , , , , , . Removal of forearm plate leads to a high risk of refracture: decision regarding implant removal after fixation of the forearm and analysis of risk factors of refracture. Arch Orthop Trauma Surg. 2014;134(12):1691-1697.
    [Google Scholar]
  5. , , , , , , . Peri-implant failure in dual plating of the distal humerus—a biomechanical analysis with regard to screw and plate positioning. Injury. 2015;46(11):2142-2145.
    [Google Scholar]