Bilateral femoral concurrent neck with shaft fractures – A case report
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Bilateral femoral concurrent neck with shaft fracture is rare and requires meticulous planning to achieve successful outcome. Case: We report a rare case of bilateral femoral concurrent neck with shaft fracture. Initially, damage control procedure of external-fixator application was performed followed by conversion to bilateral reconstruction femoral nailing. Patient required additional procedure on one side for femur shaft nonunion by augmentation plating and bone grafting to achieve union. Conclusion: Use of single intramedullary implant with anatomical reduction of the neck and achieving correct length, alignment, rotation along with good compression at the diaphyseal fracture site plays a key-role in the successful outcome in these rare fractures.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
The ipsilateral neck with shaft of femur fracture ranges from 3 to 6% amongst all femoral fractures.1 Concurrent bilateral fractures of the femoral neck and shaft are rare injuries and the incidence is yet to be reported. These are usually high velocity injuries occurring in young individuals. Shaft of femur fractures are usually due to direct impact, whereas the neck of femur fracture occurs due to secondary impact. As a result, patients usually sustain a comminuted shaft of femur fracture with an undisplaced or minimally displaced neck of femur fracture which is usually missed in the initial assessment. Prompt recognition of these fractures using a standard pelvic radiograph helps to decide on early and appropriate management of the patient. In these injuries, a vast array of treatment options ranges from hip spica in the pediatric population to open reduction and internal fixation of both the fractures and include almost all permissible combinations in between .2 These rare injuries pose a major challenge to the surgeon on deciding the treatment options. However, there is no compelling study to support either single or dual construct implant of choice for concomitant shaft with neck of femur fracture. Herein, we report our experience with this rare injury in a polytrauma patient with bilateral neck with shaft of femur fracture which achieved a successful outcome.
2 Case report
A thirty-two-year-old male sustained multiple fractures during a motor vehicle accident and was admitted in our hospital with closed neck and shaft fracture of left femur and closed neck with middle third shaft and intraarticular fracture of right distal femur (Fig. 1) At the time of presentation, the patients GCS was 15/15. The patient had a pulse rate of 106/minute, blood pressure of the patient was 84/60 mm of Hg and spo 2 was 92% in room air. On day 1 blood investigations, the patient's lactate level was 8.6 and hemoglobin was 11.7. Patient was resuscitated with five units of normal saline and two units of blood transfusion in the initial 48 hours and the lactate levels and blood pressure returned to normal. On the day of admission, patient underwent external-fixator application for bilateral concurrent neck with shaft of femur fracture (Fig. 2a). As the repeat haemoglobin of the patient in post operative day 3 was 6.9 hence, the patient was further transfused with two units of packed red blood cells on postoperative day 4 and 5. After being adequately resuscitated the patient was planned for definitive surgery in the form of a staged procedure on post operative day 7. A week after external fixator application, patient underwent closed reduction with reconstruction femoral nailing for left femur and closed reduction with reconstruction femoral nailing for right neck with shaft of femur fracture and cancellous screw application for right distal femur fracture (Fig. 2b). Patient was placed in the fracture table in scissor position. Boot traction was applied for the left lower limb with external fixator in situ. Neck of femur fracture was reduced under C arm with Leadbetter maneuver and was temporarily held in position with a 3mm Steinman pin. Finally with piriformis entry reconstruction femoral nailing was done to fix the left neck with shaft of femur fracture (Fig. 2c). Similar technique was used to fix the right neck with shaft of femur fracture. Post-surgical fixation patient underwent in bed mobilization for 6 weeks following which he was started on full weight bearing standing on the left side and non-weight bearing standing on the right side. After 3 months, patient was ambulated full weight bearing with the aid of a walker. At the end of one-year, bilateral neck of femur, right shaft of femur and right distal femur fracture united but left shaft of femur fracture showed signs of non-union (Fig. 3a). Hence patient underwent augmentation plating with bone grafting for left shaft of femur nonunion after removal of fibrous tissue and freshening of bone edges at the non-union site (Fig. 3b). Post two months of nonunion surgery patient was made to bear full weight on both lower limbs with the aid of walker and was started on calcium and vitamin D supplementation for a period of 3 months. After 8 months, all the fractures united (Fig. 4) and the patient was ambulated independently without any aid. The patient had got 0–105° range of motion in both the knees during our final follow-up (Fig. 5) and was able to perform all his routine activities without any pain.








3 Discussion
Although concomitant fracture of femur involving neck and shaft are rare, improper implant choice and inadequate fracture reduction can lead to serious consequences.1,3 Only one case of bilateral neck with shaft of femur fracture is documented till date, which reported a patient who was treated with cancellous screw fixation for neck fracture and DCP plate fixation for shaft of femur fracture, which lead to early failure of fixation because of using too few screws in the distal segment of femur.4 Usually, concurrent neck with shaft of femur fracture is associated with multiple injuries and there is significant debate regarding the timing of surgery, sequence of fixation and optimal implant of choice for femoral neck with shaft fracture.5,6 In such cases definitive fixation must be done after the patient is adequately resuscitated. Bilateral femoral shaft fractures have been associated with increased incidence of pulmonary failure in the form of ARDS, necessitating damage control orthopaedics in these special scenarios.7 Although there is confusion regarding which fracture needs to be fixed first in a simultaneous neck with shaft of femur fracture, in our institute, we usually fix both the fracture simultaneously with reconstruction nail after temporarily reducing the neck fracture using a Steinman pin with the shaft external fixator in situ. The limitation in our technique was not achieving adequate compression at the diaphyseal fracture site of left femur during conversion of external fixator to interlocking nailing. Also, transverse fracture in diaphyseal region of long bones is prone for nonunion. So, adequate compression during the first surgery or primary bone grafting could have possibly avoided nonunion at the diaphyseal fracture site in our case. However, regular follow up and managing the non-union at the right time with augmentation plating and iliac crest bone grafting helped us achieve good results in the right time frame.
4 Conclusion
Prompt recognition of the fracture with standard pelvis radiographs, anatomic reduction of neck and achieving correct length, alignment and rotation at the diaphyseal fracture site with reconstruction nail could be an appropriate management for these patients. Practice of damage control orthopaedics in polytrauma cases by stabilizing the patient initially with external fixator application and adequate resuscitation of the patient with crystalloids and packed red blood cells before definitive fixations also play a pivotal role in the management of such cases.
Funding declaration
The authors received no financial support for the research, authorship, and/or publication of this article.
Ethical standard statement
All procedures performed in the study involving the human participant were in accordance with the ethical standards of the institutional ethical committee and with the 1964 Helsinki declaration and its later amendments.
Informed consent
Written informed consent to participate in the study was collected from the patient. Patient was informed that data concerning the case would be submitted for publication and he agreed.
CRediT authorship contribution statement
Zackariya Mohamed Jafrullah: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing. Sudipta kumar Patra: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing. Dheenadhayalan Jayamaraju: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing. Rajasekaran Shanmuganathan: Conceptualization, Data curation, Formal Analysis, Investigation, Methodology, Writing – original draft, Writing – review & editing.
References
- Ipsilateral femoral neck and shaft fractures: complications and their treatment. Clin Orthop Relat Res. 2002;99:78-86.
- [Google Scholar]
- Special topic: ipsilateral femoral neck and shaft fractures–Does evidence give us the answer? Injury. 2015;46(3):478-483.
- [Google Scholar]
- A cascade of preventable complications following a missed femoral neck fracture after antegrade femoral nailing. Patient Saf Surg. 2013;7(1):1-7.
- [Google Scholar]
- Bilateral simultaneous femoral neck and shafts fractures-A case report. Arch. Bone Joint Surg.. 2014;2(4):268.
- [Google Scholar]
- Diagnosis and management of ipsilateral femoral neck and shaft fractures. JAAOS-Journal of the American Acad. Orthopaedic Surg.. 2018;26(21):e448-e454.
- [Google Scholar]
- Ipsilateral femoral neck and shaft fractures: case series from a single Level-I trauma centre and review of literature. Eur J Orthop Surg Traumatol. 2023;33(4):803-809.
- [Google Scholar]
- Increased morbidity and mortality after bilateral femoral shaft fractures: myth or reality in the era of damage control? Injury. 2013;44(2):221-225.
- [Google Scholar]