Can radiographic parameters predict favourable outcomes in proximal humeral hemiarthroplasty for fractures? – A case series
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Implant positioning and tuberosity fixation is challenging when performing proximal humerus hemiarthroplasty for proximal humerus fractures due to loss of normal anatomical landmarks. Determining tuberosity healing radiographically remains crucial. We aim to describe radiographic parameters after a proximal humerus hemiarthroplasty and assess its correlation to postoperative clinical and functional outcomes.
We conducted a retrospective study of 30 patients who underwent cemented hemiarthroplasty for proximal humerus fractures from 2010 to 2016. UCLA scoring was assessed 2 years post-surgery. Radiographic parameters measured on post-operative x-ray taken at 2 years follow up include Prosthetic Acromial Interval (PAI), Greater Tuberosity Position (GTP), Humeral-Prosthetic Offset (HPO) and a novel measurement, the Glenoid Ratio (GR). The mean age and follow-up were 67.5 ± 12.6 years and 7.7 ± 4.6 years respectively. Postoperatively, two patients had lucencies around the cement mantle. Mean PAI was 7.9 ± 5.8 mm, GTP 9.4 ± 9.6 mm, HPO 26.7 ± 4.5 mm, GR 0.48 ± 0.10. Twenty-two (75.9%) patients had a GR between 0.4 and 0.6. Deltoid tuberosity index was 1.4 ± 0.18. There was no significant association between the radiographic parameters and UCLA scoring. Two-year mean UCLA score was 24.8 ± 5.1.9/29 (31.3%) patients had a good UCLA score. No revisions, infections or periprosthetic fractures were seen at latest follow up.
Rotator cuff integrity and healing of tuberosities in proximal humerus hemiarthroplasty are important factors for successful hemiarthroplasty. This study explored the use of radiographic measurements to determine tuberosity position and hence infer rotator cuff integrity. However, these measurements do not correlate with the clinical outcome in this series of patients. Serial measurements of these measurements may correlate with functional outcomes and should be studied.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
Proximal humerus fractures account for 6% of all fractures and have a bimodal distribution.1 Young patients with healthy bones are amenable to surgical fixation while elderly patients with osteoporotic bones often require arthroplasty.
While hemiarthroplasty is effective in reducing pain when compared to non-surgical management, postoperative range of motion and function remain controversial, with studies showing suboptimal outcomes.2,3 Reverse shoulder arthroplasty, which is typically used for rotator cuff arthropathy, has emerged as an alternative to hemiarthroplasty for the treatment of acute proximal fractures.4 While many studies have found that RSA offers better clinical and functional outcomes than hemiarthroplasty, they have also demonstrated that RSA has high rates of postoperative complications and early reoperations.5,6 These are undesirable for elderly, especially for the frail and unwell ones.
In arthroplasty, loss of normal anatomical landmarks in proximal humerus fractures creates a challenge in implant positioning with regard to the prosthesis height and retroversion. This is especially critical in hemiarthroplasty as functional outcomes often depend on tuberosity healing and rotator cuff integrity.6
Patients reported outcomes (PROMs) are subjective measures of function and pain. To improve outcomes, there is a need for objective measurements for post operative radiographs after shoulder hemiarthroplasty. Thus, the aim of this study is to develop surrogate radiographic measures of implant positioning and rotator cuff integrity, and assess their correlation to clinical and functional outcomes. We hypothesise that there is difference in the radiographic parameters of patients who have a good or excellent UCLA score compared to patients who have a poor or fair UCLA score.
2 Methodology/case series
We conducted a retrospective study of 30 patients who underwent primary shoulder hemiarthroplasty from 2010 to 2016 at our institution for comminuted proximal humeral fractures. Range of motion and strength were recorded and functional scoring was done at 2 years post-surgery using the UCLA Shoulder Score. A score greater than 27 out of 35 is considered to be a good or excellent result. To demonstrate a Minimally Important Clinical Difference (MCID) of 8.7 on UCLA score with a standard deviation of 5.8 after surgery and a β of 0.2, a sample size of 18 patients is required, as reported by Simowitch et al.7
Statistical analysis was performed using SPSS for Windows using the Chi-square test for categorical variables and Student's t-test for continuous variables.
2.1 Surgical technique
Shoulder hemiarthroplasty was performed under general or regional anaesthesia in a beach chair with the arm draped free using the delto-pectoral approach. The decision to proceed with the hemiarthroplasty was made when the rotator cuff was assessed to be intact on-table. Advanced imaging such as ultrasound or Magnetic Resonance Imaging (MRI) was not routinely used to determine rotator cuff integrity before surgery. Cemented Bigliani-Flatow or Global Advantage implants were used. Tuberosity fragments bearing the insertions of the rotator cuff were reduced & fixed by non-absorbable sutures though drill-holes through the humerus cortex. Bone grafting of the tuberosity fragments to the shaft was done using cancellous bone harvested from the humeral head.
Patients were kept on an arm sling for the first 1 month after surgery before starting range of motion exercises out of arm sling.
2.2 Radiographic parameters
Anteroposterior radiographs of the shoulder in internal rotation taken at 2 years post-operatively was evaluated by an independent observer who did not participate in any of the surgeries. The following radiographic parameters were measured:1.Prosthesis-acromion index (PAI)
This is measured as the vertical distance between the inferior edge of the acromion and the highest point of the prosthesis (AB) on the antero-posterior radiograph of the shoulder taken in internal rotation (Fig. 1). It is analogous to the acromial humeral index measuring proximal migration of the humeral head and both terms are used interchangeably in the study.82.Greater tuberosity position (GTP)

This is measured as the vertical distance between the highest point of the prosthesis to the highest point on the greater tuberosity (BC) (Fig. 1). Firstly, a vertical line was drawn down the midline of the shaft of the humerus. Subsequently, two lines were drawn perpendicular to the first line. One was drawn across the most superior point of the articular surface while the other was drawn across the most superior point of the greater tuberosity. The ideal height of greater tuberosity has been described by Loebenberg et al. to be 10–16 mm below humeral head.93.Humeral-prosthesis offset (HPO)
This is measured as the distance between the centre of rotation of the prosthesis (as described by a circle) to the lateral edge of the greater tuberosity (DE) (Fig. 1). This is analogous to the offset of the hip for the total hip arthroplasty.4.Glenoid Ratio (GR)
To measure the centering of the prosthetic humeral head relative to the glenoid on the coronal plane, we describe a novel measurement, the Glenoid Ratio, which is the ratio of the vertical distance between the highest point of the glenoid and the point of greatest contact (midpoint between AE) between the prosthetic humeral head and glenoid over the vertical height of the glenoid (AC/AB) (Fig. 2). A perfectly centred humeral head would have a glenoid ratio of 0.5 as represented by point D (Fig. 2).

The Deltoid Tuberosity Index (DTI) was used to assess the cortical bone quality of the patients. Pre-operative AP radiographs of the shoulder were used instead to measure the DTI for greater accuracy in the absence of the prosthesis. DTI was calculated by dividing the outer cortical distance by the inner endosteal diameter at the level proximal to the deltoid tuberosity where the outer cortical borders become parallel.10
3 Results
Our study had 14 male and 16 female patients with a mean age of 67.5 ± 12.6 years at time of surgery. One patient died in the first year due to E.coli sepsis from urinary tract infection and was excluded from analysis. Mean duration of follow-up was 7.7 ± 4.6 years. One patient did not have a visible greater tuberosity on radiograph taken at 2 years postoperatively. No revisions, infections or periprosthetic fractures were seen at latest follow up.
At 2 years, the mean forward flexion was 93.7 ± 13.0°. The mean UCLA score at 2 years was 24.8 ± 5.1. Only 9 (31.3%) patients had a good or excellent UCLA score as defined by a score of more than 27. The lower scoring components of the UCLA were Active Forward Flexion and Strength of Forward Flexion (Table 1). Twenty-four (82.7%) patients were satisfied with their surgery (Table 1). Mean forward flexion was 93.7 ± 13.0°. Two patients had lucencies seen around the cement mantle.
| Pain (10 = painless) | 7.7 ± 2.5 |
| Function (10 = normal) | 6.9 ± 2.1 |
| Active Flexion (5 = greater than 150°) | 3.7 ± 1.0 |
| Strength of forward flexion (5 = normal) | 4.0 ± 0.7 |
| Satisfaction (5 = satisfied) | 24 (82.7%) satisfied |
| Overall Score (max 35) | 24.8 ± 5.1 |
The mean Prosthesis Acromial Index (PAI) was 7.9 ± 5.8 mm, Greater Tuberosity Position (GTP) 9.4 ± 9.6 mm, Humeral-Prosthesis Offset (HPO) 26.7 ± 4.5 mm and the Glenoid Ratio (GR) was 0.48 ± 0.10. Twenty-two (75.9%) patients had a Glenoid Ratio of 0.4–0.6 which was considered to be well-centred. The Deltoid Tuberosity Index was 1.4 ± 0.18.
There was no statistically significant difference in radiographic parameters between patients who had a good or excellent UCLA score and those who had a poor or fair score (Table 2). Although there was a 2 mm difference in GTP between the two groups, this did not reach statistical significance (Table 2).
| Good/Excellent UCLA Scores (n = 9) | Fair/Poor UCLA Scores (n = 20) | p-value | |
| Prosthesis Acromial Index (mm) | 7.8 ± 4.2 | 7.7 ± 6.2 | 0.96 |
| Greater tuberosity position (mm) | 10.5 ± 10. | 8.5 ± 5.5 | 0.61 |
| Humeral prosthesis offset (mm) | 27.7 ± 2.8 | 26.3 ± 5.1 | 0.47 |
| Glenoid Ratio | 0.47 ± 0.09 | 0.48 ± 0.11 | 0.76 |
| Deltoid tuberosity index | 1.5 ± 0.2 | 1.4 ± 0.2 | 0.45 |
4 Discussion
Hemiarthroplasty is widely accepted as one of the standards of care for proximal humerus fractures that are either not amenable to surgical fixation or at risk of avascular necrosis.11 While pain relief post hemiarthroplasty is satisfactory and reproducible across studies, functional recovery remains unpredictable and often suboptimal.3,12–17 Likewise, our study found that hemiarthroplasty provides overall good pain relief, but range of motion and strength were uniformly poor. It is important to highlight that while 69% (n = 20) of our patients have fair/poor functional outcomes, the satisfaction rate remained high at 82.7%, suggesting that most elderly patients prioritize pain relief over functionality. With regard to radiological parameters, the main finding of this study was that there was no significant difference between the two groups of patient outcomes for all measured parameters.
Conventionally, acromial humeral index (AHI) measures the proximal migration of the humeral head and when narrowed, is indicative of a subacromial impingement, rotator cuff tear or tendinopathy. In our study, though we observe a 2 mm difference in the prosthesis-acromial index (PAI) between the groups, this did not reach statistical significance. While Hashiguchi et al. reported a positive correlation between Constant score and PAI, Pijls et al. did not find any significant correlation between the two.18,19 On the other hand, Shah et al. found that while functional outcomes did not correlate with superior migration of the prosthesis (i.e. decreased PAI), rotator cuff quality remained an important predictor of functional outcomes.20 This suggests that while decreased AHI is strongly correlated to complete rotator cuff tear in an unoperated shoulder,21 the same may not hold true in cases where there are anatomical disruptions due to shoulder hemiarthroplasty or a fracture. Moreover, in the current study, only a single measurement of PAI at 2 years follow up was recorded. PAI is dynamic and may change due to rotator cuff disorders following hemiarthroplasty due to either degeneration or failure of tuberosity healing.22 This is consistent in a study by Noyes et al. which reported a decrease in PAI over time from 2 to 5 years after surgery.22 Moreover, an in vitro study by Nyffeler et al. found positioning the humeral head prosthesis proximal to the anatomic position (i.e. small PAI) can potentially lead to long-term failure of the supraspinatus tendon.23 Given the circumstances, initial post-operative PAI measurement may not reflect actual rotator cuff health and serial measurements to look any decrease in PAI might be more useful. Therefore, restoring an anatomical or pre-injury acromial humeral interval might be the key to ensure reliability of PAI measurements. However, this is also seemingly challenging given that Besch et al. was only able to reproduce the acromial humeral distance equal to the uninjured side in 44% of the patients.24
Ensuring union of tuberosities has been a focus for a successful hemiarthroplasty, with several studies correlating tuberosity healing with increased functional outcomes.25–28 However, achieving tuberosity healing is often very difficult in hemiarthroplasty.29,30 Loebenberg et al. proposed several factors for good tuberosity healing: (1) Prosthesis should not put excessive tension on tuberosities, and (2) Tuberosities must be adequately secured to the prosthesis, the shaft and to each other.9 With those considerations, a tuberosity position of 10–16 mm below the humeral head was recommended. According to the recommendation, the mean Greater Tuberosity position in our series of patients was suboptimal at 9.4mm. Yet, there was only one patient (3.3%) with greater tuberosity resorption at follow-up. The disagreement in results suggest that tuberosity healing could also be influenced by other factors. This is evident in our study which found that tuberosity position did not differ between the two groups of different functional outcomes. A cadaveric study by Borowsky et al. found that failure of tuberosity healing may be a mechanical phenomenon where sutures “dig into” tendon and cut partially through bones after repetitive contractions and use, leading to loss of cancellous bony volume and thus suture laxity.31 On the other hand, Boileau et al. reported that the use of a fracture-specific humeral stem produced better tuberosity healing over the standard humeral stem, which could possibly explain the low resorption rates in our study.32
Lastly, in terms of anatomical positioning, a study of 359 cases of primary shoulder hemiarthroplasty that required surgical revision found that 63% of the cases had decentering of the humeral component on the glenoid surface.33 While fracture lines often distort anatomical landmarks that are essential in correctly positioning the prosthesis during hemiarthroplasty, Greiner et al. found that the pectoralis major tendon is a consistent landmark that can mitigate this concern.34 For post-operative evaluation, Esen et al. found that a humeral offset of ≥24mm results in good to excellent outcomes post hemiarthroplasty.35 We report a humeral prosthesis offset of ≥24mm in both groups with no significant difference between them. Additionally, we described a novel radiological parameter, the Glenoid Ratio, to further measure humeral centering on the coronal plane. Similarly, no difference in Glenoid Ratio was observed between the groups and only 24.1% of our patients had decentering of the humerus. Our findings have reinforced several points: (1) Different rates of humerus decentering across studies suggest that differences in operative techniques can affect humerus centering; (2) While centering of the humerus is important, there are more important factors to be considered when evaluating outcomes post hemiarthroplasty.
This study is to the author's knowledge, one of the first few studies to assess the correlation between radiographic markers of tuberosity healing and functional outcomes at long-term follow up. However, some potential limitations of our study include its retrospective nature, a relatively small sample size, and the inability to obtain preinjury functional data of our patients. Moreover, the radiological parameters were measured only by one independent observer. Lastly, our study lacked the use of advanced imaging (computed tomography scan and MRI) to evaluate rotator cuff integrity preoperatively and to determine the implant's degree of retroversion after surgery, which directly affects the mobility and stability of the shoulder.36
5 Conclusion
Shoulder hemiarthroplasty can be used for displaced proximal humerus fractures in elderly who prioritize pain relief. While this study shows that surrogate radiographic measurements for rotator cuff integrity and implant positioning do not correlate with clinical outcome, it raises a new possibility for future research on how serial measurements of these parameters may correlate to functional outcomes instead.
Financial support and sponsorship
None.
Informed consent
The Sing-Health CIRB has approved waiver of informed consent based on ethical consideration.
Authors contribution
Conceptualization and Design: S.S, K.L.P, D.L.
Acquisition of Data: S.S, K.L.P, D.L.
Analysis and Interpretation of Data: S.S, K.L.P, D.L.
Writing – Original Draft: S.S, K.L.P, D.L.
Writing – Review and editing: S.S, K.L.P, D.L.
Disclaimer
None.
References
- Trends and variation in incidence, surgical treatment, and repeat surgery of proximal humeral fractures in the elderly. J Bone Joint Surg Am. 2011;93(2):121-131.
- [Google Scholar]
- Early management of proximal humeral fractures with hemiarthroplasty: a systematic review. J Bone Joint Surg Br. 2008;90(11):1407-1413.
- [Google Scholar]
- Hemiarthroplasty versus nonoperative treatment of displaced 4-part proximal humeral fractures in elderly patients: a randomized controlled trial. J Shoulder Elbow Surg. 2011;20(7):1025-1033.
- [Google Scholar]
- Reverse shoulder arthroplasty for the treatment of three- and four-part fractures of the proximal humerus in the elderly: a prospective review of 43 cases with a short-term follow-up. J Bone Joint Surg Br. 2007;89(4):516-520.
- [Google Scholar]
- Reverse total shoulder arthroplasty versus hemiarthroplasty for proximal humeral fractures: a systematic review. J Orthop Trauma. 2015;29(1):60-68.
- [Google Scholar]
- Hemiarthroplasty versus reverse shoulder arthroplasty for treatment of proximal humeral fractures: a meta-analysis. J Shoulder Elbow Surg. 2016;25(2):330-340.
- [Google Scholar]
- Quantifying success after total shoulder arthroplasty: the minimal clinically important difference. J Shoulder Elbow Surg. 2018;27(2):298-305.
- [Google Scholar]
- Proximal migration can be measured accurately on standardized anteroposterior shoulder radiographs. Clin Orthop Relat Res. 2006;443:260-265.
- [Google Scholar]
- The effect of greater tuberosity placement on active range of motion after hemiarthroplasty for acute fractures of the proximal humerus. Bull Hosp Jt Dis. 2005;62(3-4):90-93.
- [Google Scholar]
- Deltoid tuberosity index: a simple radiographic tool to assess local bone quality in proximal humerus fractures. Clin Orthop Relat Res. 2015;473(9):3038-3045.
- [Google Scholar]
- Osteosynthesis and hemiarthroplasty of fractures of the proximal humerus: outcomes in a consecutive case series. J Shoulder Elbow Surg. 2009;18(2):216-219.
- [Google Scholar]
- Shoulder hemiarthroplasty for acute fractures of the proximal humerus: a minimum five-year follow-up. J Shoulder Elbow Surg. 2008;17(2):202-209.
- [Google Scholar]
- Shoulder hemiarthroplasty for fractures of the proximal humerus. Musculoskelet Surg. 2011;95(Suppl 1):S49-S54.
- [Google Scholar]
- Medium-term results after primary hemiarthroplasty for comminute proximal humerus fractures: a study of 46 patients followed up for an average of 4.4 years. J Shoulder Elbow Surg. 2007;16(6):766-773.
- [Google Scholar]
- Results of uncemented hemiarthroplasty as primary treatment of severe proximal humerus fractures in the elderly. Eur J Orthop Surg Traumatol. 2015;25(2):273-280.
- [Google Scholar]
- Intermediate-term outcome of hemiarthroplasty for comminuted proximal humerus fractures. J Shoulder Elbow Surg. 2017;26(1):85-91.
- [Google Scholar]
- Shoulder hemiarthroplasty for complex humeral fractures: a 5 to 10-year follow-up retrospective study. Musculoskelet Surg. 2014;98(Suppl 1):27-33.
- [Google Scholar]
- Primary uncemented hemiarthroplasty for severe fractures of the proximal humerus. J Orthop Trauma. 2011;25(5):279-285.
- [Google Scholar]
- The outcome of hemiarthroplasty for proximal humeral fractures is dependent on the status of the rotator cuff. Int Orthop. 2015;39(6):1115-1119.
- [Google Scholar]
- Shoulder hemiarthroplasty for the treatment of three and four part fractures of the proximal humerus using Comprehensive® Fracture stem. Int Orthop. 2011;35(6):861-867.
- [Google Scholar]
- Association between rotator cuff tears and superior migration of the humeral head: an MRI-based anatomic study. Orthopaedic Journal of Sports Medicine. 2021;9(6)
- [Google Scholar]
- Functional and radiographic long-term outcomes of hemiarthroplasty for proximal humeral fractures. J Shoulder Elbow Surg. 2011;20(3):372-377.
- [Google Scholar]
- Influence of humeral prosthesis height on biomechanics of glenohumeral abduction. An in vitro study. J Bone Joint Surg Am. 2004;86(3):575-580.
- [Google Scholar]
- Hemiarthroplasty of the shoulder after four-part fracture of the humeral head: a long-term analysis of 34 cases. J Trauma. 2009;66(1):211-214.
- [Google Scholar]
- Functional outcome of shoulder hemiarthroplasty for fractures: a multicentre analysis. Injury. 2010;41(6):606-612.
- [Google Scholar]
- Functional outcome after primary hemiarthroplasty in three or four part proximal humerus fracture: a short term followup. Indian J Orthop. 2016;50(6):590-594.
- [Google Scholar]
- Hemiarthroplasty for the treatment of complex proximal humeral fractures: does a trabecular metal prosthesis make a difference? A prospective, comparative study with a minimum 3-year follow-up. J Shoulder Elbow Surg. 2014;23(10):1437-1443.
- [Google Scholar]
- Cement technique correlates with tuberosity healing in hemiarthroplasty for proximal humeral fracture. J Shoulder Elbow Surg. 2017;26(3):437-442.
- [Google Scholar]
- Tuberosity malposition and migration: reasons for poor outcomes after hemiarthroplasty for displaced fractures of the proximal humerus. J Shoulder Elbow Surg. 2002;11(5):401-412.
- [Google Scholar]
- Reverse shoulder arthroplasty in acute fractures of the proximal humerus: does tuberosity healing improve clinical outcomes? J Orthop Trauma. 2019;33(2):e46-e51.
- [Google Scholar]
- Is failure of tuberosity suture repair in hemi-arthroplasty for fracture mechanical? J Shoulder Elbow Surg. 2013;22(7):971-978.
- [Google Scholar]
- Can surgeons predict what makes a good hemiarthroplasty for fracture? J Shoulder Elbow Surg. 2013;22(11):1495-1506.
- [Google Scholar]
- Primary shoulder hemiarthroplasty: what can Be learned from 359 cases that were surgically revised? Clin Orthop Relat Res. 2018;476(5):1031-1040.
- [Google Scholar]
- Reconstruction of humeral length and centering of the prosthetic head in hemiarthroplasty for proximal humeral fractures. J Shoulder Elbow Surg. 2008;17(5):709-714.
- [Google Scholar]
- Factors affecting results of patients with humeral proximal end fractures undergoing primary hemiarthroplasty: a retrospective study in 42 patients. Injury. 2009;40(12):1336-1341.
- [Google Scholar]
- CT scan method accurately assesses humeral head retroversion. Clin Orthop Relat Res. 2008;466(3):661-669.
- [Google Scholar]