Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Research Article
2025
:4;
100516
doi:
10.1016/j.jorep.2024.100516

Translate:

Comparative analysis of surgical techniques for pediatric diaphyseal forearm fractures: A focus on titanium flexible nails versus plates and screws

Author affiliations
Kerman University of Medical Science, Kerman, Iran
Department of Orthopedics, Kerman University of Medical Sciences, Kerman, Iran
Department of Pediatrics, Kerman University of Medical Sciences, Kerman, Iran
Article History
Corresponding author(s)

∗Corresponding author: Shahab Ilka. drshahabilka@gmail.com

Article tools · PDF & citations

Abstract

Abstract

Diaphyseal forearm fractures are frequently encountered in patients with immature skeletons. Proper management of these fractures is crucial for achieving the best possible outcomes. In this study, we compare two prevalent fixation methods for pediatric diaphyseal forearm fractures: plate and screw fixation versus titanium elastic nails (TEN).

This study was a prospective, randomized controlled trial conducted at Shahid Bahonar Hospital in Kerman, Iran. Fifty patients, aged 10–16 years, with diaphyseal fractures of the radius and ulna, were randomly assigned to one of two groups: TEN or AO–Dynamic Compression Plate (DCP). Surgical duration, length of hospitalization, and complications were assessed post-surgery. Three months post-surgery, functional outcomes and fracture union time were evaluated.

Our study involved 50 patients with an average age of 12.1 years. The TEN group had significantly shorter surgery duration (mean 73 minutes vs. 98 minutes, p = 0.035) and hospital stay (mean 1.2 days vs. 2.1 days, p = 0.027) compared to the DCP group. No significant differences were observed in fracture union time (p = 0.73) or functional outcomes at three months (p = 0.143). Complications were minimal, with skin irritation being more common in the TEN group, while superficial wound infections were noted in the DCP group.

TEN fixation is an effective approach for pediatric diaphyseal forearm fractures, providing the advantage of shorter surgical and hospitalization times compared to plate and screw fixation methods. Additionally, the smaller incision leads to improved cosmetic results and minimizes soft tissue injury.

Keywords

  • Diaphyseal forearm fractures
  • Pediatric fracture
  • Bones fixation
  • Intramedullary nailing
  • Plate and screw
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Fractures involving the forearm bones, specifically the distal ulna and radius, account for approximately 10 % of all fractures in children.1 With an incidence of 738.1 per 100,000 individuals per year, these fractures are among the most prevalent pediatric injuries. They have a variable age distribution, with a peak occurrence in males and females at 11 and 9, respectively.2 These fractures are often attributed to sports and falls, and the most common site for a refracture is the distal forearm.2–4

The selection of appropriate treatment strategies and the application of effective therapeutic interventions for forearm fractures are critical to ensuring optimal patient outcomes.5 Although most distal forearm fractures can be effectively treated with closed reduction and casting, surgery is necessary in specific situations.6,7 These include instances of unsuccessful reduction, significant fracture displacement, and unstable elbow fractures, particularly in cases involving simultaneous fractures of the arm bone and nearing skeletal maturity.8–13 In younger children, whose growth plates are more open and possess a higher remodeling capacity, achieving acceptable relative correction through closed reduction is typically feasible. The natural ability of their bones to remodel and adapt allows for a significant degree of correction without the need for invasive procedures. This capacity is particularly advantageous in managing fractures, as it minimizes the need for surgical intervention and reduces the risk of complications associated with open surgery, such as infection or prolonged recovery.14,15 However, as children age beyond 10 years, the remodeling capacity diminishes considerably, often necessitating complete correction, which frequently requires surgical interventions.6,16

Although the conventional approach of closed reduction and forearm casting yields favorable outcomes in many cases, it's important to note its limitations, particularly in instances of significant displacement. Studies have reported a notable 29 % failure rate in the treatment of such cases using this method.17–19 Specifically, fractures characterized by angulation exceeding 15° and malrotation greater than 45° are associated with a higher likelihood of suboptimal healing and long-term functional impairment. Moreover, factors such as the quality of the cast, including its ability to provide stable immobilization, and patient compliance with post-casting care, play a significant role in determining treatment outcomes.18,20,21

Various surgical techniques are applied to distal forearm fractures, including fixation using external fixators, intramedullary nails (IMNs), and plate and screw fixation.7,22,23 In recent years, there has been a notable surge in the utilization of surgical approaches, particularly titanium IMNs, for treating radius and ulna diaphyseal fractures.20,24,25 When considering the use of screws and plates for fracture fixation, several issues arise, including the need for a sizable incision, which can lead to larger scars and aesthetic concerns, especially in pediatric patients. Additionally, the procedure involves extensive soft tissue manipulation, which can increase the risk of complications such as infection, delayed healing, or damage to surrounding tissues. Another challenge associated with this method is the potential difficulty in future removal of screws and plates.26,27 Conversely, the use of flexible titanium elastic nail (TEN) presents several advantages. This technique requires smaller incisions, resulting in less scarring and a faster recovery. Furthermore, the minimally invasive nature of the procedure reduces soft tissue trauma, lowering the risk of complications. The nails also provide adequate stability through 3-point fixation mechanisms, ensuring that the bone is properly supported during the healing process. The flexible design of these nails allows for micro-motion at the fracture site, which has been shown to facilitate early callus formation and expedite the healing process.2,26,28,29 Notably, achieving anatomical reduction, especially concerning the radius bone, is crucial for ensuring optimal future range of motion, an achievement often better accomplished with the screw and plate method due to direct visualization.30–32

Over the past two decades, numerous studies have explored fixation methods for radius and ulna fractures in children and adolescents, comparing the disadvantages and advantages of various approaches alongside patient outcomes.23,28,33–35 Several studies have indicated that IMNs are a safe and effective option for stabilizing forearm fractures.2,24,36,37 A recent study involved patients under the age of 15 with distal forearm fractures, treated using flexible TEN, reported successful fracture union, with an average healing time of 10 weeks.36 Similarly, postoperative results of another study with TEN, showed excellent outcomes in the majority of cases, enabling early mobilization with a very low complication rate.38 When comparing fixation methods, patients treated with IMNs showed no significant differences in fracture union or forearm rotation compared to those treated with screws and plates. However, the nailing technique resulted in shorter operative times, without increasing the complication rate.28,35 Additionally, IMNs offered faster recovery, better cosmetic outcomes, and simpler nail removal, making it a suitable option for uncomplicated diaphyseal forearm fractures.39

Given the high prevalence of forearm fractures and the various treatment modalities available, extensive studies are necessary to evaluate the outcomes associated with different therapeutic approaches. Specifically, the significance of addressing angular deformities and malrotation cannot be overstated, as these factors can significantly impede supination and pronation movements of the forearm.40–42 This study set out to compare the outcomes of two fixation methods for diaphyseal forearm fractures: using screws and plates versus flexible TENs. This study uses a randomized controlled trial to compare the duration of surgery, length of hospitalization, fracture healing time, long-term functionality, and potential complications across both patient groups.

2

2 Methods

2.1

2.1 Study design and participants

This study employed a prospective, randomized controlled trial involving patients admitted to the Department of Orthopedic Surgery at Shahid Bahonar Hospital in Kerman, Iran. The primary inclusion criteria for the participants were diaphyseal fractures of the radius and ulna bones and an aged between 10 and 16 years. Exclusion criteria included patients with diaphyseal fractures involving the radio-ulnar joints (Monteggia and Galeazzi), pathological fractures, fractures with extensive comminution, re-fractures of the radius and ulna diaphysis, open fractures, and ages less than ten years or more than 16 years.

The sample size was calculated using statistical methods and formulas to ensure adequate power for detecting differences between the two surgical methods. A total of 50 individuals were enrolled, with 25 patients randomly assigned to each treatment group. Randomization was conducted using a random number table to assign patients to one of two treatment groups: fixation with TENs or fixation with screws and plates (AO–Dynamic Compression Plate).

2.2

2.2 Interventions

For intramedullary nailing fixation, the patient was set in a supine position on a radiolucent table to provide optimum imaging, during surgery. A tourniquet was applied above the elbow if needed to reduce bleeding and enhance visibility during surgery. Following standard aseptic preparations and careful protection of the radial sensory nerve to prevent nerve damage, along the proximal to distal side of the radius, a 5 mm longitudinal incision was performed. The incision provided access to the intramedullary canal, where a flexible TEN, typically measuring 2–3 mm in diameter depending on the patient's bone size, was inserted. The intramedullary canal and fracture site were carefully navigated with the nail. Continuous fluoroscopic guidance was used to ensure proper alignment and positioning of the implant. When the fracture was so significantly displaced or angulated that a closed reduction was not possible, a small incision was performed at the fracture site to allow for an open reduction. This enabled to manipulate the fracture manually and observe it clearly, ensuring accurate realignment.

A similar technique was employed for the ulna, taking care in order to prevent injury to the ulnar nerve during the insertion of the titanium nail. Once both nails were properly positioned, ensuring stability and appropriate fixation of the fracture, the incisions were closed with sutures. The ends of the nails were bent beneath the skin to avoid irritation or complications from protruding hardware. In order to immobilize the limb and protect the surgical site during the recovery process, a long arm cast was subsequently applied. Depending on the extent of the fracture and the patient's healing process, the cast was typically maintained for a duration of four to six weeks.

For fixation with plates and screws, a tourniquet was applied to the patient's arm to control bleeding and improve surgical visualization. The anterior part of the forearm was incised longitudinally using the Henry approach, which is widely used for exposing the radius while minimizing damage to surrounding structures. To prevent any neurovascular complications, the adjacent arteries and nerves were protected while the fracture site on the radius bone was carefully exposed between the flexor muscles. Once the fracture was visualized and anatomically reduced, a 3.5 AO–Dynamic Compression Plate (DCP) was selected, and screws were applied to achieve stable fixation. The plate's design allowed for compression across the fracture site, promoting healing by ensuring secure and precise bone alignment.

To address the ulna, a dorsolateral incision was made to access the bone, utilizing a similar technique to expose and reduce the fracture. As with the radius, care was taken to preserve the surrounding soft tissues, particularly avoiding damage to the nearby ulnar nerve. Numerous parameters, such as the type and position of the fracture, the level of comminution, and the patient's general body size, were considered when choosing the number and size of holes in the plate. The plate was set up against at least six cortices on either side of the fracture in most cases to provide a stable and secure fixation. Following fixation, a vacuum drain was placed to prevent the accumulation of fluids, reducing the risk of postoperative complications such as hematoma formation. The incisions were then meticulously sutured, ensuring proper wound closure. Finally, a splint was applied to immobilize the limb, providing additional support and protection to the surgical site during the initial healing phase. Fig. 1 provides examples of both fixation methods.

Intramedullary nailing fixation (a) vs. plates and screws fixation (anterior (b) and lateral (c) view).
Fig. 1 Intramedullary nailing fixation (a) vs. plates and screws fixation (anterior (b) and lateral (c) view).
2.3

2.3 Outcomes and follow-up

Demographic information, including age, gender, and mechanism of injury, was recorded for each participant upon their visit to the hospital. Surgical parameters, including the duration of surgery and the length of hospitalization after surgery, were documented in the operating room and patient records, respectively. Length of hospitalization was determined by counting the days spent in the hospital following surgery, whereas surgical duration was counted from the beginning to the end of the procedure.

During the study's follow-up phase, participants were required to attend the orthopedic clinic at predefined intervals for comprehensive evaluations. These follow-up visits were crucial for monitoring the healing process and assessing the functional recovery of the patients. Using a goniometer, the elbow's range of motion (ROM) was assessed during each visit, providing precise data on flexion, extension, and rotational movements. Additionally, fracture union time was assessed based on radiographic evidence, specifically the formation of bridging callus across at least three of the four cortices in both anteroposterior and lateral views. This radiographic confirmation was paired with the clinical absence of pain at the fracture site, which further indicated successful healing and progression towards union. Functional outcomes were evaluated using the Price et al. criteria,21 a widely accepted method for categorizing patients based on their range of rotational movements. According to Price et al. criteria, a loss of less than 15° in forearm rotation and no complaints during intense activity are characteristics of an “Excellent” result. Mild symptoms during intense activity and an impairment of forearm rotation between 15° and 30° are indicators of a “Good” result. “Fair” results are characterized by little discomfort during everyday activities and a loss of 31°–90° of forearm rotation. Any other result with an absence of forearm rotation more than 90° is considered a “Poor” outcome. A comparison was made between the surgically repaired and unaffected forearms, and each patient was assigned to one of four functional recovery groups. Furthermore, thorough examinations were performed to assess and record any complications. These could include issues such as infection, hardware irritation, or delayed healing. However, blinding of the study was not feasible during these evaluations, as the type of surgery (IMN or plate fixation) was evident based on the size and location of surgical scars, as well as the radiographic characteristics visible on follow-up imaging.

2.4

2.4 Statical analysis

Data management and analysis were conducted using SPSS software version 22. For the comparison of parametric variables between the two groups, an independent samples t-test was applied, which allowed for the assessment of differences in continuous data, such as fracture union time and range of motion. The Mann-Whitney U test was used to examine non-parametric variables in situations where the data did not match the requirements of normality. This approach offered a reliable way to compare the median values between the groups. A p-value of less than 0.05 was considered significant.

2.5

2.5 Ethical point of view

All participants in this study were under legal age, so informed consent was obtained from their parents or legal guardians, who were thoroughly informed about the study protocol. Before data collection, the investigation was explained in detail to the parents or guardians, who provided consent. The potential benefits and risks of the study were clearly outlined prior to consent. Throughout data collection and the presentation of results, no patient names or identifying information that could compromise privacy were used. The Kerman University of Medical Sciences Ethics Committee provided ethical approval, following the guidelines of the Helsinki Declaration (Ethical Code: IR.KMU.AH.REC.1398.075). The trial is registered under the code IRCT20200111046080 N1, available in the Iranian Registry of Clinical Trials.

3

3 Results

A total of 50 patients were recruited for the study and divided into two groups at random: 25 in the TEN group and 25 in the DCP group, to evaluate the two surgical techniques.

3.1

3.1 Demographic characteristics

The study involved 50 patients, with a mean age of 12.1 years. Of these, 42 % were female and 58 % were male. Mechanisms of injury were predominantly attributed to falls in both groups, with road traffic accidents accounting for a smaller proportion. Furthermore, the distribution of fractures between the right and left sides was similar across both treatment groups, indicating a balanced representation of injuries. A summary of the baseline characteristics for both groups is provided in Table 1 and Fig. 2. Age, gender, fracture side, and injury mechanism did not differ significantly between the two groups (p > 0.05).

Table 1 Main characteristics of the study samples.
TEN Group DCP Group
Gender Male 60 % 57 %
Female 40 % 43 %
Mean age (years) 11.8 12.3
Side of fracture Right 58 % 59 %
Left 42 % 41 %
Mechanism of injury Road traffic accident 15 % 19 %
Falling 85 % 81 %
Distribution of the main characteristics of the study samples.
Fig. 2 Distribution of the main characteristics of the study samples.

Out of the total 25 patients who underwent surgery using the TEN fixation method, 6 patients (24 %) experienced intraoperative difficulties where the nails were unable to pass through the fracture site without additional manipulation. This complication typically occurred when the fracture was either too displaced or angulated, which made it difficult for the nail to pass easily into the intramedullary canal. In such cases, a small incision was created at the site of one or both bones' fracture to accomplish relative reduction and enable direct manipulation of the fracture segments. This enabled the surgeon to align the bones properly and facilitate the insertion of the nail through the intramedullary canal.

3.2

3.2 Surgical duration and hospitalization

The duration of surgery, from the initiation to completion of the procedure, was significantly shorter in the TEN group compared to the DCP group. The average surgery duration in the TEN group was 73 minutes, ranging from 47 to 115 minutes, while in the DCP group, it averaged 98 minutes, with a range of 75–132 minutes (Table 2, Fig. 3).

Table 2 Mean duration of surgery and hospitalization.
TEN Group (Mean (Range)) DCP Group (Mean (Range)) P-value
Duration of surgery (Minute) 73 (47–115) 98 (75–132) 0.035
Duration of hospitalization (Day) 1.2 (1–2) 2.1 (1–3) 0.027
Duration of surgery.
Fig. 3 Duration of surgery.

Similarly, the length of hospitalization post-surgery was notably shorter in the TEN group compared to the DCP group. Patients treated with TEN fixations had an average hospital stay of 1.2 days, ranging from 1 to 2 days, while those who underwent plate and screw fixation had an average stay of 2.1 days, with a range of 1–3 days.

3.3

3.3 Fracture union time

Assessment of fracture union time revealed no significant difference between the TEN and DCP groups. Both treatment modalities exhibited comparable rates of bone healing, with the average time to union was 8.6 weeks for the DCP group and 9.5 weeks for the TEN group (Table 3).

Table 3 Mean duration of fracture union.
TEN Group DCP Group P-value
Fracture Union Time (weeks) 9.5 8.6 0.73
3.4

3.4 Patient functional outcomes

The evaluation of patient functional outcomes, specifically range of motion, at three months post-surgery demonstrated no significant difference between the two treatment groups. Using the Price et al. criteria, patients were categorized based on their ability to perform pronation and supination movements of the forearm. As shown in Table 4, both the TEN and DCP groups exhibited similar proportions of patients classified as having excellent, good, fair, or poor outcomes after 3 months post-surgery.

Table 4 Patients’ functional outcomes.
TEN Group DCP Group P-value
Excellent 76 % 80 % 0.143
Good 20 % 20 %
Fair 4 % 0 %
Poor 0 % 0 %
3.5

3.5 Complications

Surgical complications were minimal in both treatment groups. In the DCP group, three cases of superficial wound infections were observed, which were managed conservatively without the need for further surgical intervention. Conversely, the most common complication in the TEN group was skin irritation at the site of nail prominence, predominantly observed in two lean patients. Notably, one case of proximal migration of the ulna nail resulted in skin penetration and exposure, highlighting a potential risk associated with IMN fixation. However, major vascular or nerve complications were not encountered in either group.

4

4 Discussion

The findings of this study contribute to the growing body of literature on the management of pediatric diaphyseal forearm fractures, particularly in the context of comparing fixation methods. The significantly shorter surgical duration and hospitalization time associated with TEN fixations underscore its potential advantages over plate and screw fixation, including reduced surgical complexity and postoperative recovery time. Importantly, despite differences in surgical technique, both fixation methods demonstrated comparable rates of fracture union and patient functional outcomes, emphasizing their efficacy in facilitating bone healing and restoring forearm mobility.

Traditionally, immobilization in a cast and closed reduction were the standard treatments for pediatric both forearm fractures.6 However, internal fixation options, including plating, intramedullary nailing, and pinning, have become more prevalent. Successful results for both IMN and plate and screw fixation have been described; however, surgical therapy for both bone forearm fractures usually depends on the surgeon's expertise and preference 28,32. Among the operative techniques, IMN is often favored over compression plating due to the lower risk of complications like infection, nonunion, ischemic contracture, nerve injury, or radioulnar synostosis. Additionally, IMN fixation has been shown to provide shorter operating times, less soft tissue dissection, faster mobilization, and easier hardware removal.19,33

The results of this study reflect those of Reinhardt et al.,28 who compared IMN fixation vs. plate and screw fixation in 31 adolescents. They found that the nailing group's surgical duration (103.4 minutes) was noticeably shorter than that of the other group (132.6 minutes). Additionally, there was no difference in the amount of forearm rotation lost or in union time between the two groups. This also accords with our earlier findings, which indicated comparable rates of fracture union and patient functional results with both fixing techniques. These results also support evidence from previous observations by Shah et al.35 who analyzed 61 cases of both-bone forearm fractures, comparing flexible TEN with open reduction and internal fixation. The internal fixation group (8.9 weeks) and the TEN group (8.5 weeks) had comparable average times to union. Despite the radial bow being displaced distally due to IMN, over two-thirds of patients in both groups recovered full forearm rotation. This finding is contrary to a previous study by Freese et al.33 which observed longer union times, along with fracture angulation and displacement, in patients treated with IMN fixation. Their study found that the nailing group had an average time to radiographic union of 68 days, whereas the plate fixation group had a median duration of 58 days. This outcome is unexpected, as older age is generally associated with slower bone healing due to reduced bone density and regenerative capacity. Prior evidence suggested that age differences between groups can influence healing rates, with older patients typically exhibiting slower fracture union.43 However, in our study, the similar age distribution between the two groups likely minimized any age-related effects on healing time.

In terms of complications, while superficial wound infections were more prevalent in the DCP group, skin irritations were a notable concern in the TEN group, particularly in lean individuals. Only one major complication, nail migration, was detected in the TEN group. The complications observed in this investigation are different from those observed by Reinhardt et al.28 They found more major complications, such as ulna nonunion, refractures, and compartment syndrome, with a lower percentage occurring in the nailing group. This outcome is contrary to that of Shah et al.,35 who reported only three minor complications in the nailing group, such as superficial nerve palsy and bursitis. In contrast, the internal fixation group had serious complications such as nonunion, delayed union, malunion, and refracture. It is difficult to explain this outcome, but it might be related to the severity of the fractures, the patient's care, and the patient's follow-up after their discharge from the hospital. The observed complications in our study, although minimal, highlight important considerations for surgical decision-making and patient counseling. These findings underscore the importance of patient selection, intraoperative technique, and postoperative monitoring in mitigating potential complications associated with each fixation method.

The findings of this study provide support for the use of TEN fixation as a viable alternative to plate and screw fixation for pediatric both bone forearm fractures. The less invasive nature of the TEN procedures facilitates faster recovery and discharge, along with minimal complications. Moreover, the minimally invasive nature of TEN fixation may contribute to improved cosmetic outcomes and reduced soft tissue trauma, enhancing patient satisfaction and quality of life.

5

5 Conclusion

The present study was designed to compare two fixation methods—screws and plates versus flexible TENs—for diaphyseal forearm fractures. The results of this investigation show that TEN fixations demonstrated a significantly shorter surgical duration and postoperative hospitalization. This efficiency, coupled with comparable rates of fracture union time, patient functional outcomes, and minimal complications, highlights the potential of TENs as a preferred surgical approach for pediatric forearm fractures. Our study provides orthopedic surgeons and other healthcare professionals with important assistance by clarifying the subtleties of two different surgical methods and outcomes in pediatric forearm fractures, facilitating informed decision-making, and optimizing patient care.

The absence of long-term follow-up in this study limited the ability to assess complications like re-fracture. To confirm these findings and evaluate long-term consequences, such as the risks of refracture and hardware removal, more research with large samples and longer follow-up periods is required. Additionally, comparative studies exploring the cost-effectiveness and patient-reported outcomes of different fixation methods would provide valuable insights for clinical decision-making and optimization of patient care.

Ethical statement

This study, ethically approved by the Ethics Committee of Kerman University of Medical Sciences (approval code: IR.KMU.AH.REC.1398.075), aligns with the World Medical Association's Declaration of Helsinki and follows recommendations for ethical conduct in medical research.

Patient consent Statement

Written informed consent was obtained from the parents or legal guardians for the publication of anonymized information in this article. Parents and guardians were assured that no names or initials would be disclosed, and every effort would be made to protect the anonymity of the patients.

Funding

The authors declare that there was no direct or indirect financial support by extramural sources for the study or related studies.

CRediT authorship contribution statement

Fatemeh Shahrahmani: Investigation, Formal analysis, Writing – original draft, Writing – review & editing. Reza Khosravi: Conceptualization, Investigation, Resources, Writing – review & editing. Shahab Ilka: Conceptualization, Project administration, Supervision, Writing – review & editing. Sahar Heidarabadipour: Investigation, Writing – review & editing.

References

  1. , , . Distribution of physeal and nonphyseal fractures in 2,650 long-bone fractures in children aged 0-16 years. Journal of pediatric orthopedics. 1990;10(6):713-716.
    [Google Scholar]
  2. , , , , . Low complication rate of elastic stable intramedullary nailing (ESIN) of pediatric forearm fractures: a retrospective study of 202 cases. Medicine. 2017;96(16):1-7.
    [Google Scholar]
  3. , , , , , . Epidemiology of pediatric fractures presenting to emergency departments in the United States. J Pediatr Orthop. 2016;36(4):45-48.
    [Google Scholar]
  4. , , , , , , . Incidence of childhood distal forearm fractures over 30 years: a population-based study. JAMA. 2003;290(11):1479-1485.
    [Google Scholar]
  5. , et al . Does time to surgery for distal radius fractures impact clinical and radiographic outcomes? A systematic literature review. Current Orthopaedic Practice. 2023;34(5):229-235.
    [Google Scholar]
  6. , et al . Management of pediatric forearm fractures: what is the best therapeutic choice? A narrative review of the literature. Musculoskeletal surgery 2021:1-10.
    [Google Scholar]
  7. , . Pediatric distal radius and forearm fractures. J Hand Surg. 2008;33(10):1911-1923.
    [Google Scholar]
  8. , . Pediatric fractures of the forearm. Clin Orthop Relat Res. 2005;432:65-72.
    [Google Scholar]
  9. , , , , . Nonoperative treatment of both-bone forearm shaft fractures in children: predictors of early radiographic failure. Journal of pediatric orthopedics. 2011;31(1):23-32.
    [Google Scholar]
  10. , et al . Treatment outcomes of both-bone diaphyseal paediatric forearm fractures. Injury. 2013;44:S11-S15.
    [Google Scholar]
  11. , , , , , , . Long-term outcomes of closed reduction and percutaneous pinning for the treatment of distal radius fractures. The Journal of hand surgery. 2008;33(10):1700-1705.
    [Google Scholar]
  12. , , , , , , . Forearm diaphyseal fractures in the adolescent population: treatment and management. European journal of orthopaedic surgery & traumatology. 2015;25:201-209.
    [Google Scholar]
  13. , , , . The management of pediatric open forearm fractures. J Hand Surg. 2020;45(6):523-527.
    [Google Scholar]
  14. , , , , . Evaluation of bone age in children: a mini-review. Frontiers in Pediatrics. 2021;9:2296-2360.
    [Google Scholar]
  15. , , , . Stress and growth in children and adolescents. Horm Res Paediatr. 2023;96(1):25-33.
    [Google Scholar]
  16. , et al . The determinants of peak bone mass. J Pediatr. 2017;180:261-269.
    [Google Scholar]
  17. , , , . Closed treatment of displaced diaphyseal both-bone forearm fractures in older children and adolescents. Journal of pediatric orthopedics. 2005;25(4):507-512.
    [Google Scholar]
  18. , et al . Treatment of diaphyseal forearm fractures in children. Orthop Rev. 2014;6(2):5325.
    [Google Scholar]
  19. , et al . Outcome of diaphyseal pediatric forearm fractures following non-surgical treatment in a Level I Trauma Center. Int J Health Sci. 2018;12(5):60.
    [Google Scholar]
  20. , , , , . Eleven years experience in the operative management of pediatric forearm fractures. J Pediatr Orthop. 2010;30(4):313-319.
    [Google Scholar]
  21. , , , , . Malunited forearm fractures in children. Journal of pediatric orthopedics. 1990;10(6):705-712.
    [Google Scholar]
  22. , . State-of-the-art treatment of forearm shaft fractures. Injury. 2005;36:25-34.
    [Google Scholar]
  23. , , , , . Treatment of pediatric both-bone forearm fractures: a comparison of operative techniques. J Pediatr Orthop. 2005;25(3):309-313.
    [Google Scholar]
  24. , , , , , , . Intramedullary wire fixation for unstable forearm fractures in children. Injury. 2006;37(10):966-973.
    [Google Scholar]
  25. , , , , , , . A review and critical analysis of the history of intramedullary nailing. Current Orthopaedic Practice. 2024;35(4):135-144.
    [Google Scholar]
  26. , , , . Systematic review: functional outcomes and complications of intramedullary nailing versus plate fixation for both-bone diaphyseal forearm fractures in children. Injury. 2014;45(8):1135-1143.
    [Google Scholar]
  27. , , , , , , . Complications following palmar plate fixation of distal radius fractures: a review of 665 cases. Arch Orthop Trauma Surg. 2013;133:1155-1162.
    [Google Scholar]
  28. , , , , , , . Comparison of intramedullary nailing to plating for both-bone forearm fractures in older children. J Pediatr Orthop. 2008;28(4):403-409.
    [Google Scholar]
  29. , , , , , , . Alternative treatment of forearm double fractures: new design intramedullary nail. Arch Orthop Trauma Surg. 2014;134:1387-1396.
    [Google Scholar]
  30. , , , , , . Complications of titanium elastic nails for pediatric femoral shaft fractures. J Pediatr Orthop. 2003;23(4):443-447.
    [Google Scholar]
  31. , , , , . Intramedullary nailing versus plate fixation for unstable forearm fractures in children. J Pediatr Orthop. 1998;18(1):9-13.
    [Google Scholar]
  32. , , , , , . Both bone forearm fractures in children and adolescents, which fixation strategy is superior—plates or nails? A systematic review and meta-analysis of observational studies. J Orthop Trauma. 2014;28(1):8-14.
    [Google Scholar]
  33. , , , , , . A comparison of fixation methods in adolescent patients with diaphyseal forearm fractures. Injury. 2018;49(11):2053-2057.
    [Google Scholar]
  34. , , , . Comparison of treatment with titanium elastic nail versus AO–dynamic compression plate for femoral shaft fractures in children. Annals of King Edward Medical University. 2016;22(1):30.
    [Google Scholar]
  35. , , , , , , . Stabilization of adolescent both-bone forearm fractures: a comparison of intramedullary nailing versus open reduction and internal fixation. J Orthop Trauma. 2010;24(7):440-447.
    [Google Scholar]
  36. , , . Functional outcome of both bone fracture forearm managed with titanium elastic intramedullary nail system in pediatric age group. National Journal of Clinical Orthopaedics. 2018;2(1):37-41.
    [Google Scholar]
  37. , , , , , . Use of elastic stable intramedullary nailing for treating unstable forearm fractures in children. J Trauma Acute Care Surg. 2008;65(1):109-115.
    [Google Scholar]
  38. , , , , , . Flexible intramedullary titanium elastic nailing of fracture shaft of radius and ulna in children at a tertiary care teaching hospital. Ortho and Rheum Open Acces J. 2016;2(2):555-584.
    [Google Scholar]
  39. , , , . Functional outcome following intramedullary nailing or plate and screw fixation of paediatric diaphyseal forearm fractures: a systematic review. Journal of children's orthopaedics. 2012;6(1):75-80.
    [Google Scholar]
  40. , . A study of radioulnar movements following fractures of the forearm in children. Clin Orthop Relat Res. 1979;139:114-120.
    [Google Scholar]
  41. , , . Pediatric forearm malunions. Hand Clin. 2024;40(1):35-48.
    [Google Scholar]
  42. , et al . The evolution of hand function during remodelling in nonreduced angulated paediatric forearm fractures: a prospective cohort study. J Pediatr Orthop B. 2020;29(2):172-178.
    [Google Scholar]
  43. , , , , . Effects of aging on fracture healing. Curr Osteoporos Rep. 2017;15:601-608.
    [Google Scholar]
Show Sections