Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Research Article
2025
:4;
100480
doi:
10.1016/j.jorep.2024.100480

Translate:

Correlation between peroneus longus graft profile and anthropometric data in patients undergoing anterior cruciate ligament reconstruction – An Indian scenario

Author affiliations
MOSC Medical College, Kolenchery, PIN – 682311, Kochi, India
Article History
Corresponding author(s)

⁎Corresponding author: Melvin J. George. johnirimpenz@yahoo.co.in

Article tools · PDF & citations

Abstract

Abstract

There are published literature regarding the correlation between Hamstring tendon (HT) graft profile and anthropometric data in patients undergoing ACL reconstruction from India; but not with Peroneus longus tendon (PLT). We hypothesise a positive correlation between the peroneus longus graft profile and few of patient's anthropometric variables.

Sixty eight patients who underwent Arthroscopic ACL Reconstruction using PLT graft were evaluated. Intraoperatively, tripled PLT graft length and diameter were correlated to the patient's age, height, weight, duration of injury, and BMI.

This study included 50 males and 18 females. Mean age was 29.2 ± 8.3 years, mean height was 169.8 ± 3.1 cm, mean weight was 78.4 ± 4.5 kg, mean BMI was 26.4 ± 0.1 kg/m2, mean duration of injury was 2.2 ± 4.9 months, mean graft diameter was 8.9 ± 0.6 mm and mean graft length was 8.5 ± 0.8. Positive correlation with graft length and diameter was found only with height and weight (p < 0.01).

Patient's height and weight, have a significant direct correlation with tripled PLT graft length and diameter.

Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The most important restraint that prevents anterior translation of tibia on femur is the anterior cruciate ligament (ACL).1 When ACL is torn, arthroscopic anterior cruciate ligament reconstruction is frequently performed to prevent further instability and early arthritic changes.2–4 Recent studies identify graft diameter as one of the critical parameters that affect the functional outcome of ACL reconstruction (ACLR).5–7 A graft diameter of at least 8 mm is preferable to reduce the risk of revision surgery and provide a predictable result.8–10

The hamstring graft is the one frequently used to in ACL reconstruction. But, decreased internal rotation strength, sensory loss along the medial part of the leg, and frequently observed insufficient length and diameter are its disadvantages.11–14 Most of the studies show that the average diameter of hamstring tendon grafts is less than 8 mm.2,10 In order to achieve adequate graft thickness, gracilis tendon may also be needed to be harvested.15,16 This combined tendon harvest can have a detrimental impact on knee flexion power.

Peroneus longus tendon harvesting has gained popularity recently due to its simplicity of harvest, low donor site morbidity, predictable results, and guaranteed length and diameter.17,18 There aren't many research articles that compare the anthropometric measurements of patients with PLT grafts in the Indian community.

2

2 Methods

2.1

2.1 Objective

This study evaluated the association between various anthropometric parameters and the PLT graft length and diameter.

2.2

2.2 Study design

The study was planned as a prospective cohort study. The cohort included patients undergoing ACL reconstruction using a tripled peroneus longus autograft at our centre from May 2021 to April 2023.

2.3

2.3 Participants

The inclusion criteria were patients between 18 and 52 years of age, patients with ACL tear alone with or without meniscal tear and a complete follow up of 1 year following ACLR. Exclusion criteria were stiff ankle, multi-ligament knee injury, osteoarthritic knees, previous surgery in the ipsilateral knee and history of fractures around the ankle and knee.

The study commenced after obtaining Institutional Ethics Committee clearance. Patients diagnosed with ACL tear were pooled. Thorough clinical examination was done (Lachman test, anterior drawer test and pivot shift test). Tests were also done to exclude tear of the Posterior Cruciate Ligament (PCL) and the Postero-Lateral Corner (PLC). Patients were evaluated with X rays of knee and ACL tear was confirmed by MRI.

Those planned for Arthroscopic ACL Reconstruction were counselled regarding the study and informed consent was taken from all. Anthropometric data were recorded pre-operatively which included age, height, weight, BMI along with date of injury and surgery.

A single surgeon did all the cases. Graft harvest, preparation and measurement was done by the same surgeon. Tourniquet was used routinely. Standard anterolateral and anteromedial arthroscopy portals were made. ACL rupture was confirmed through diagnostic arthroscopy. Peroneus longus tendon was harvested from the ipsilateral leg for ACL reconstruction.

A 3 cm incision marked 1cm above and behind the lateral malleolus (Fig. 1a). Deep dissection is done. Peroneus longus (PL) and Peroneus brevis (PB) tendons are identified (Fig. 1b). PL and PB are sutured together distally with 2-0 vicryl absorbable sutures. PL is isolated, severed above the suture and stripped with a tendon stripper till 5 cm below fibular head (Fig. 1c).

a,b,c showing the steps of Peroneus Longus tendon graft harvest.
Figure 1 a,b,c showing the steps of Peroneus Longus tendon graft harvest.

After the muscle fibres were removed from the harvested graft, graft length is measured. The tripled graft ends were sewn together with a running whip stitch 4–5 cm from the free ends using polybraided nonabsorbable suture material (number 2 ethibond). The graft is prepared in the standard fashion and diameter measured using a sizer by pulling the graft across the sizer. (Fig. 2). The prepared graft is looped across the femur and tibial tunnels and suspended with adjustable loop endobutton on femoral side and fixed to tibia with a biocomposite screw in the standard fashion. (Fig. 3).

showing the prepared graft.
Figure 2 showing the prepared graft.
showing the arthroscopic image of the graft insitu.
Figure 3 showing the arthroscopic image of the graft insitu.

The patients were followed up at 6weeks, 3 & 6 months, and at 1year post-operative. Every visit, all the patient were scored based on IKDC and Lysholm scores for knee and AOFAS and FADI scores for foot and ankle. All patients were also provided post operative physiotherapy as per our standard Protocol; where during 0–2 weeks – walker assisted partial weight bearing walking with knee brace locked in extension, ROM - 0 to 70° and ankle pumps were advised. During 3–6 weeks – Free walking with brace, ROM 0–125° were advised. Post 6 weeks – patients are off brace, strengthening exercises started and jogging were promoted. We also made sure that the physiotherapy was advised to all patients by a dedicated single Sports physiotherapist according to our Institution protocol.

Study size was decided based on previous literature on the same or similar topics. Data analysis was done using SPSS software, version 20.0 (IBM Corp., Chicago). The normality of data was assessed through the test of normality. Pearson correlation coefficient was used to measure correlation between anthropometric variables and PLT diameter. Regression analysis was done to assess the impact of variables like age, height, weight, BMI, and injury duration on graft diameter. A p value of less than 0.05 was considered statistically significant.

3

3 Results

50 males and 18 females who met the inclusion criteriae and underwent the surgery were taken up for the study. Most common mechanism of injury was Sports injury (41.18 %) followed by domestic injuries (32.35 %).

Mean age of the patients was 29.2 ± 8.3 years, mean height was 169.8 ± 3.1 cm, mean weight was 78.4 ± 4.5 kg, mean BMI was 26.4 ± 0.1 kg/m2, mean duration of injury was 2.2 ± 4.9 months [Table 1].

Table 1 Showing patient demographics.
Variable n Mean Minimum Maximum SD
Age 29.2 18 52 8.3
Sex Male 50
Female 18
Mechanism RTA 18
Sports Injury 28
Domestic injury 22
Height 68 169.8 159 184 3.1
Weight 68 78.4 68 92 4.5
BMI 68 26.4 22 30 0.1
Duration of injury (months) 68 2.2 2 15 4.9

The mean graft diameter was 8.9 ± 0.6 mm and mean graft length was 8.5 ± 0.8. Positive correlation with graft length and diameter was found only with height and weight (p < 0.01) [Table 2].

Table 2 Showing mean values of the variables.
Variable n Mean Minimum Maximum SD
Tendon length after harvest (cm) 68 31.8 27 35 2.6
Graft diameter (tripled PLT in mm) 68 8.9 8 10 0.6
Graft length (tripled PLT in mm) 68 8.5 7 9 0.8

Five patients (7.3 %) had a graft diameter of less than 8 mm, 8–9 mm in 44 patients (64.7 %),9–10mm in 19 patients (27.94 %). At 1 year follow up, mean IKDC score was 93.7 ± 9.8, mean Lysholm score was 96.1 ± 5.2. The mean AOFAS score was 97.6 ± 5.7 and the mean FADI score was 97.9 ± 4.8. [Table 3].

Table 3 Showing PLT graft diameter distribution.
Diameter Frequency Percentage
7.5 5 7.3
8 7 10.3
8.5 22 32.3
9 15 22.01
9.5 14 20.59
10 5 7.35

Only height and weight were significantly associated with graft diameter; both showing positive correlation [ height and graft diameter (r = 0.6, P < 0.01); weight and graft diameter (r = 0.4, P < 0.01)]. No correlation was found between BMI and graft diameter (r = 0.06, P > 0.05), age and graft diameter (r = 0.2, P > 0.05) and duration of injury and graft diameter (r = 0.09, P > 0.05) [Table 4].

Table 4 showing Pearson correlation between graft diameter and anthropometric variables.
Variable r 95%CI p
Age 0.2 −0.007–0.021 >0.05
Height 0.7 0.54 to 0.13 <0.01
Weight 0.4 0.02 to 0.082 <0.01
BMI 0.05 −0.16 to 0.1 >0.05
Graft diameter 0.08 −0.03 to 0.022 >0.05
Tendon length 0.06 −0.045 to 0.016 >0.05
Duration of injury 0.09 −0.044 to 0.029 >0.05
4

4 Discussion

Graft diameter is always a key component in deciding how successful an ACL reconstruction would become. Most of the studies on ACLR grafts are done on Hamstring tendon. Most of the researches have highlighted positive correlation of graft variables with height and weight of the patients.19 Research studies on the diameter of peroneus ligament grafts is relatively scarce.

In 2018, Song et al.15 assessed the relationship between anthropometric measurements and PLT diameter in 136 patients. With a correlation coefficient of 0.62, they discovered that height and PLT diameter have the strongest relationship. In a smaller cohort, Rhatomy et al.16 in 2019 found similar results. (the correlation value is 0.41). Sakti et al.18 observed a strong correlation between graft thickness and height in their investigation of 20 patients. A similar result with height (correlation coefficient of 0.7) was also noted in our investigation. Height was similarly reported to be the best predictor of graft diameter in hamstring grafts by Park et al.,10 Pereira et al.,20 Asif et al.,2 and Celiktas et al..19 Weight was found to follow a similar pattern.15,16,18 Weight and BMI have also been found to be directly correlated with the graft diameter by Song et al.15 and Rhatomy et al..16 In order to determine a direct correlation, Celiktas et al.19 and Sakti et al.18 examined hamstring graft thickness and connected it with height and weight. However, there was no association found between the two factors by Pereira et al..20 Nonetheless, a significant correlation was noted by Boisvert et al.21 between BMI and hamstring graft diameter. PLT diameter and height showed the highest association in our study, followed by weight and BMI.

There was no discernible relationship between PLT graft diameter, gender, or duration of injury. On the other hand, Song and colleagues noted a noteworthy distinction in the diameter of the male and female peroneus longus grafts. We could not find such an association in our study.

In our study, the observed PLT average graft diameter was 8.9 ± 0.6 mm, with 95 percent of patients having graft diameter more than 8 mm. The average tendon length in our study is 31.8 cm, which is comparable to the length reported by Shi et al.,15 where the average tendon length was 300 mm. Recent studies suggest a diameter of minimum 8 mm for a predictable successful outcome, even though it is still not completely established.22 In that case, it will be prudent to consider PLT graft as the preferred choice as highlighted in few recent studies.23,24

Ankle function and donor site morbidity were the key factors keeping the surgeons away from peroneus longus tendon graft. These were unaffected in our patient group during the one-year follow-up. There was no sign of plantarflexion weakness or eversion in the ankle or foot. The average FADI score was 97.9 ± 4.8 and the average AOFAS score was 97.6 ± 5.7, both of which are comparable to normal people. Suturing the PLT stump with the Peroneus Brevis tendon (PBT) helps retain foot function; as Peroneus Brevis is the principal evertor. At the one-year follow-up, our patients' group showed no change in ankle function or donor site morbidity. The ankle and foot showed no signs of plantarflexion weakness or eversion. Both the mean FADI score and the mean AOFAS score were as good as in normal patients, at 97.9 ± 4.8 and 97.6 ± 5.7, respectively.

5

5 Limitations & strength

The major strength of this study is that it is one of the initial studies in India to establish a relationship between the anthropometric parameters and PLT graft diameter. The result of our study adds to the significance of the results of similar studies done in other countries and races. Surgeons can have a high degree of suspicion for inadequate graft size for ACL reconstruction by using anthropometric measures. Surgeons can utilize this information to help them decide whether to use an alternate graft option. Our study's limitations include a small sample size, relatively short follow up duration and fewer female patients. Multicentre studies with a large sample size and prolonged follow up period, with a larger number of females are warranted to corroborate our findings.

6

6 Conclusion

The diameter of the peroneus longus graft is correlated with anthropometric parameters. The strongest correlation is seen between height and the graft profile. As the peroneus longus graft tendon has an average diameter of nearly 9 mm and it does not alter ankle scores at a one-year follow-up, it can be used as a primary graft option for patients undergoing ACLR, particularly for patients who are short and lean.

CRediT authorship contribution statement

Alexson Soney: Collected the data and did the follow up scoring. Shyam Ramesh: Supervised data collection and scoring. Melvin J. George: Performed the surgery in all the patients, monitored the progress of the study, did the necessary corrections and crucial edits in the manuscript..

Ethical statement

ETHICAL COMMITTEE/INSTITUTIONAL REVIEW BOARD CLEARANCE of MOSC MEDICALCOLLEGE KOLENCHERY has been obtained for the study

Vide No: EC/NEW/INST/2023/3520.

The study has been conducted in accordance with the ethical principles mentioned in the Declaration of Helsinski (2013).

Patients who signed the well informed consent form have only been assigned to the study.

Funding statement

The authors declare no financial support/grants/sponsorships in any forms have been received at any part of the study right from inception to completion.

References

  1. , , , , . Prediction of semitendinosus and gracilis autograft sizes for ACL reconstruction. Knee Surg Sports Traumatol Arthrosc. 2012;20:1293-1297.
    [Google Scholar]
  2. , , , , , , . Prediction of quadruple hamstring graft diameter for anterior cruciate ligament reconstruction by anthropometric measurements. Indian J Orthop. 2016;50:49-54.
    [Google Scholar]
  3. , , , , , , . Reconstruction versus conservative treatment after rupture of the anterior cruciate ligament: cost effectiveness analysis. BMC Health Serv Res. 2019;11:317.
    [Google Scholar]
  4. , , , , , , . Predicting the hamstring tendon diameter using anthropometric parameters. Arch Bone JtSurg. 2016;4:314-317.
    [Google Scholar]
  5. , , , , , . Causes of failure of anterior cruciate ligament reconstruction and revision surgical strategies. Knee SurgRelat Res. 2016;28:319-324.
    [Google Scholar]
  6. , , , , , . Factors that predict failure in anatomic single-bundle anterior cruciate ligament reconstruction. Am J Sports Med. 2017;45:1529-1536.
    [Google Scholar]
  7. , , , , , , . Graft size and patient age are predictors of early revision after anterior cruciate ligament reconstruction with hamstring autograft. Arthroscopy. 2012;28:526-531.
    [Google Scholar]
  8. , , , , , . The effect of autologous hamstring graft diameter on the likelihood for revision of anterior cruciate ligament reconstruction. Am J Sports Med. 2016;44:1475-1481.
    [Google Scholar]
  9. , , , et al . The influence of hamstring autograft size on patient-reported outcomes and risk of revision after anteriorcruciate ligament reconstruction: a Multicenter Orthopaedic Outcomes Network (MOON) Cohort Study. Arthroscopy. 2013;29:1948-1953.
    [Google Scholar]
  10. , , , , , , . Factors predicting hamstring tendon autograft diameters and resulting failure rates after anterior cruciate ligament reconstruction. Knee Surg Sports Traumatol Arthrosc. 2013;21:1111-1118.
    [Google Scholar]
  11. , , , , , , . Predicting the graft diameter of the peroneus longus tendon for anterior cruciate ligament reconstruction. Medicine (Baltim). 2018;97
    [Google Scholar]
  12. , , , , , , . Influence of anthropometric features on peroneus longus graft diameter in anterior cruciate ligament reconstruction: a cohort study. Ann Med Surg. 2019;48:77-80.
    [Google Scholar]
  13. , , , . Role of anthropometric data in the prediction of 4-stranded hamstring graft size in anterior cruciate ligament reconstruction. Acta Orthop Belg. 2016;82:72-77.
    [Google Scholar]
  14. , , , , , . Complications following harvesting of patellar tendon or hamstring tendon grafts for anterior cruciate ligament reconstruction: systematic review of literature. OrthopTraumatolSurg Res. 2017;103:245-248.
    [Google Scholar]
  15. , , , et al . The effect of gracilis tendon harvesting in addition to semitendinosus tendon harvesting on knee extensor and flexor strength after anterior cruciate ligament reconstruction. Arch Orthop Trauma Surg. 2022 Mar;142(3):465-470.
    [Google Scholar]
  16. , , , , . Anterior cruciate ligament reconstruction with bone-patellar tendon-bone autograft and a medial parapatellar portal. Arthrosc Tech. 2016;5:827-831.
    [Google Scholar]
  17. , , , , . Can we use peroneus longus in addition to hamstring tendons for anterior cruciate ligament reconstruction? Adv Biomed Res. 2014;3:115.
    [Google Scholar]
  18. , , , , , , . Predicting the peroneus longus tendon autograft size in ACL reconstruction by using anthropometric parameters: a study in South Sulawesi population. J Orthop. 2020;22:1-4.
    [Google Scholar]
  19. , , , , , , . Prediction of the quadruple hamstring autograft thickness in ACL reconstruction using anthropometric measures. Acta OrthopTraumatolTurc. 2013;47:14-18.
    [Google Scholar]
  20. , , , , , , . Correlation between anthropometric data and length and thickness of the tendons of the semitendinosus and gracilis muscles used for grafts in reconstruction of the anterior cruciate ligament. Rev Bras Ortop. 2016;51:175-180.
    [Google Scholar]
  21. , , , . Relationship between anthropometric measurements and hamstring autograft diameter in anterior cruciate ligament reconstruction. Am J Orthop Belle Mead NJ. 2011;40:293-295.
    [Google Scholar]
  22. , , , , , . Age, graft size, and Tegner activity level as predictors of failure in anterior cruciate ligament reconstruction with hamstring autograft. Am J Sports Med. 2013;41:1808-1812.
    [Google Scholar]
  23. , , , , . Peroneus longus tendon autografts have better graft diameter, less morbidity, and enhanced muscle recuperation than hamstring tendon in ACL reconstruction. Indian J Orthop. 2024 May 23;58(7):979-986.
    [Google Scholar]
  24. , , , . Tensile strength comparison between peroneus longus and hamstring tendons: a biomechanical study. Int J Surg Open. 2017;9:41-44.
    [Google Scholar]
Show Sections