Dynamization of the plate in treating nonunion of the tibial fracture: Case report
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Plate osteosynthesis for the tibial fracture is one of the alternative treatments with satisfactory outcomes. Appropriate surgical techniques, including an open or minimally invasive approach, absolute or relative stability regarding fracture characteristics, and construct stiffness, could lead to proper fracture healing. However, in some circumstances the nonunion might be a problem. The treatment of the healing disturbance is challenging as more complex procedures, such as compression plating, bone grafting, or conversion to nailing, are considered. Dynamization, which aims to optimize the rigidity of the construct, was an alternative to stimulate bone healing.
We present two cases of tibial nonunion following open reduction internal fixation (ORIF) with plating. The dynamization concept by percutaneously removing screws close to the fracture site to reduce fixation stiffness for appropriate relative stability, promote callus formation, and facilitate fracture healing without additional bone grafting. This simple procedure could be an alternative option in selected healing problem cases.
These cases highlight the importance of considering fixation construct rigidity in fracture management. Too rigid fixation with a simple fracture gap or in comminuted fracture led to delayed healing. Dynamization of plating should be considered when delayed healing is related to the fixation construct's stiffness. Screw removal, as demonstrated in this case report, can be done under local anesthesia as a simple procedure to stimulate fracture healing before more complex surgical options. However, individualized analysis of nonunion causes is essential for successful bone healing.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
The treatment of tibial fracture with plating, whether using open or minimally invasive approaches, has been effective with satisfactory outcomes. Nevertheless, the healing complications still occur with 2–12%.1,2 The management of tibial nonunion requires a comprehensive approach, considering biological and mechanical factors, soft tissue status, and individual patient characteristics. In this report, we present two cases of tibial nonunion after open reduction internal fixation (ORIF), where the “dynamization of the plate-bone construct” concept was applied to optimized construct stiffness and promote secondary fracture healing with bridging callus formation.
2 Case report
2.1 Case 1
A 30-year-old male experienced right leg pain and deformity after a motorcycle accident. The radiographs revealed a simple oblique fracture of the tibial shaft (AO-OTA 42-A2) (Fig. 1). He had no underlying disease or history of smoking. He underwent ORIF with a precontoured narrow dynamic compression plate (DCP). The postoperative radiographs demonstrated a good alignment and reduction. The patient came to follow up at 2 and 4 weeks, then every month to evaluate the healing of the fracture. He was allowed to partial weight bearing for 10–15 kg. After six months, the fracture line persisted, with increasing sclerosis over the fracture end (Fig. 2). The patient felt some soreness at the fracture when weight bearing. After analyzing the current situation, we diagnosed it as delayed union because there was no evidence of progression of healing in three consecutive follow-ups and we thought that the fixation construct was too rigid and with a gap in simple fracture pattern. This rigidity might prevent the callus formation and lead to delayed healing. After getting the patient's consent, we percutaneously remove the screws, one proximal and one distal which closed to the fracture site, to dynamize the stability of fixation. This aimed to stimulate some micromotion at the fracture ends, resulting secondary bone healing. Three months after dynamization, the fracture line was going to disappear with callus formation, then it healed uneventfully at six months (Fig. 3). Finally, he could walk with full weight bearing without pain and subsequently underwent implant removal due to implant irritation.



2.2 Case 2
A 21-year-old male who was in a motorcycle accident experienced left leg pain, deformity over the left leg. The distal neurovascular status was intact. He was treated with open reduction internal fixation with a narrow DCP in the prior hospital. The radiographs showed the acceptable alignment of the wedge tibial fracture (AO-OTA 42-B2). At 6-month follow up, the fracture line persisted without callus formation (Fig. 4). The patient reported pain while walking. We analyzed the fixation and thought that one oblique screw through the fracture might prevent the fracture motion, moreover, this was a relatively comminuted fracture that was suitable for relative rather than absolute stability. Therefore, we start dynamizing the plate by removing two screws closed to the fracture under local anesthesia. At six months, the fracture healed uneventfully (Fig. 5).


3 Discussion
This case report demonstrated the successfully application of the “dynamization of the plate-bone construct” concept in addressing delayed union of the tibial fracture after ORIF with conventional plating and achieved satisfactory fracture healing. This procedure is simple and could be considered as an option in carefully selected healing problem cases.
Perren emphasized that strain at the fracture site plays a critical role in fracture healing.3 An appropriate amount of strain, which is related to the fracture gap and interfragmentary motion, is necessary for callus formation. Motion is dependent on the fixation stiffness, which the surgeon can alter by selecting the implant material, screw type, screw location, or plate length.4 In general principle, rigid fixation aims to provide absolute stability at the fracture site in a simple fracture; on the other hand, flexible fixation aims to provide relative stability and allow some motion at the fracture site, leading to callus formation in the comminuted fracture.
Dynamization is a technique for enhancing the micromotion of the fracture and altering the stiffness of the fixation construct to promote proper bone growth. Forward dynamization is the process of making a fracture fixation construct less rigid over time, whereas reverse dynamization is an intervention that increases the rigidity of the fixation construct.5 Although commonly used with intramedullary nailing, by removing the static locking screw and leaving the dynamic locking screw or remove all screws in one side to allow axial compression of the fracture, this concept can also be applied to plating. Several methods could be considered similar to dynamization of nailing constructs such as removing the screws closer to the fracture site, exchanging the locking screws closer to the fracture site with nonlocking screws, exchanging the bicortical screws closer to the fracture site with unicortical screws, removal of screw crossing the fracture site6 or modification of screw-bone interface such as the far cortical locking screw.7
Oh et al.8 described the application of this concept in distal femoral fracture treatment with a minimally invasive distal femoral locking plate by removing the reduction screw crossing the fracture, converting the rigid fixation with a gap to a more flexible fixation, and healing the fracture with callus formation. Wu et al.9 demonstrated the treatment of tibial nonunion treated with limited open reduction with locking plate. They removed three locking screws closest to the fracture site with bone grafting and achieved successful bone healing. Both cases demonstrated possible healing complications treated with locking compression plate which was too stiff and prevented micromotion to create secondary bone healing.
Our cases demonstrated potential complications that could occurred with conventional plate, where excessive rigidity may hinder micromotion necessary for secondary bone healing. Management can be enhanced by logically altering the construct's stiffness throughout the phases of the healing process. When delayed healing occurs, dynamization of plating should be taken into consideration if the cause of failures correlated with the rigidity of the fixation construct. The screw removal in this case report can be done under local anesthesia in an attempt to stimulate fracture healing before a more complex operation, such as bone grafting, revision plating, or conversion to intramedullary nailing, to treat nonunion. However, a thorough analysis of the cause of the nonunion must be considered individually to improve the chances of successful bone healing.
Funding
No funds have been received for this study.
Inform consent
Informed consent was obtained for the patient.
Author contributions
CJ was involved in drafting and revising the manuscript for content, including the medical writing for the content and review literatures. PR, PT and TL were involved in revising the manuscript. TA was involved in revising and supervising the manuscript.
Ethic approval
This study has been approved by the ethical committees of our institute in accordance with the declaration of Helsinki.
References
- Prevalence and influencing factors of nonunion in patients with tibial fracture: systematic review and meta-analysis. J Orthop Surg Res. 2020;15(1):377.
- [Google Scholar]
- Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br. 2002;84(8):1093-1110.
- [Google Scholar]
- Implant material, type of fixation at the shaft, and position of plate modify biomechanics of distal femur Plate osteosynthesis. J Orthop Trauma. Aug 2017;31(8):e241-e246.
- [Google Scholar]
- Far cortical locking can improve healing of fractures stabilized with locking plates. J Bone Joint Surg Am. 2010;92(7):1652-1660.
- [Google Scholar]
- Dynamization of locked plating on distal femur fracture. Arch Orthop Trauma Surg. 2011;131(4):535-539.
- [Google Scholar]
- Dynamization of the locking compression plate for treating tibia nonunion: a case report. Int J Clin Exp Med. 2017;10:13818-13823.
- [Google Scholar]

