Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Research Article
2025
:4;
100407
doi:
10.1016/j.jorep.2024.100407

Translate:

Improving the adequacy of preoperative radiographic imaging for total hip arthroplasty digital templating: A quality improvement project

Author affiliations
National Orthopaedic Hospital Cappagh, Cappagh Rd, Cappoge, Dublin, 11, D11EV29, Ireland
Article History
Corresponding author(s)

⁎Corresponding author: Bisola Salaja. btsalaja@hotmail.com

Article tools · PDF & citations

Abstract

Abstract

Elective total hip replacements (THR) represent a cornerstone in enhancing patients' quality of life by providing effective pain relief, achieved through the optimization of biomechanical function by orthopaedic surgeons. The success of these procedures hinges on meticulous preoperative planning. Integral to this process is the utilization of up-to-date radiographs and digital templating software in preoperative planning, with accuracy contingent upon the control of various elements in hip radiography.

Our primary objective was to evaluate radiograph adequacy for templating in our institution and establish local guidelines. Our secondary objective was to reduce unnecessary radiation exposure by minimizing repeat templating radiographs.

Utilizing the National Integrated Medical Imaging System (NIMIS), a retrospective analysis was conducted on templating radiographs i.e. anteroposterior (AP) pelvis, from 103 consecutive total hip replacement series in our unit. Assessment criteria for adequacy included: calibration device usage, absence of pelvic rotation, radiographic centring on the pubic symphysis, adequate femoral visibility, and 10–15° internal hip rotation. Results were systematically analysed, leading to the formulation of fundamental templating guidelines presented in a poster. These guidelines were communicated to radiologists in our institution. A follow-up review of a further 103 patients assessed guideline implementation.

Templating radiography in our institution exhibited excellent overall adequacy, averaging 78 % during the project, with exclusive use of the KingMark® calibration device. A Chi-Square Test revealed a significant correlation (p = 0.4384) between interventions and radiograph adequacy, supported by a small but statistically significant effect size (Cramer's V = 0.12). A 67 % reduction in repeated radiographs occurred post-intervention.

This study contributes to refining preoperative templating accuracy in hip arthroplasty, enhancing patient outcomes. Future initiatives include the development of a formal training program for surgeons, radiologists, and radiographers within our institution, with potential implications for national implementation.

Keywords

  • Digital templating
  • Quality improvement project
  • Hip radiography
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Hip arthroplasties stand as highly effective interventions for treating arthritic and degenerative hip disorders.1 In the elective non-traumatic setting, the primary objective of total hip replacement (THR) is the enhancement of a patient's quality of life through effective pain relief. Orthopaedic surgeons achieve this by optimizing biomechanical function, resulting in markedly improved functional outcomes.1,2 Successful hip replacement surgeries are influenced by various factors, and preoperative planning and assessment play a pivotal role in optimizing outcomes.3

Preoperative planning is well-recognised in elective orthopaedic surgery. It involves an interdisciplinary team of medical experts, that highlight any potential risks that could arise in the peri-operative period.1 Over the past two decades, digital preoperative planning, or digital templating, has become integral in total hip arthroplasties (THAs).4,7 These systems provide a wide array of implant manufacturers within the software.5 This approach, facilitated by artificial intelligence, provides comprehensive information on leg length, acetabular component size and angle, stem size, resection line, and offset distance based on a calibrated appropriate anteroposterior (AP) pelvis radiograph.5 It is a quick and cost-effective tool that also creates a permanent, archived record of the templating process.

Prior to digital templating, conventional templating was utilized.6 This involved placing pre-drawn prosthetic overlays over the templating radiograph. A 13-year-old prospective cohort study carried out at the University of Toronto showed digital templating to be as reliable as conventional templating.6 This study was published while digital templating was still in its infancy. A systematic review published in 2019 has since shown digital templating to be superior in terms of accuracy due to its ability to be modified.4 In relation to calibration, a double marker technique was found to be superior to the standard metal ball method, in terms of accuracy and reliability.4 A median error of 1.14 % vs 6 % was found between the double marker and single marker methods respectively.

This study focuses on the radiographic image required for templating. Recognizing significant variability in requested hip templating radiographs, we evaluated their adequacy and subsequently established local best practice guidelines to enhance standards. To the best of our knowledge, this project represents the first of its kind in the existing literature, and it aims to refine the accuracy of preoperative templating in hip arthroplasty, ultimately contributing to improved patient outcomes.

2

2 Methods

This quality improvement project was conducted in Dublin's National Orthopaedic Hospital Cappagh during the period September 1, 2021 - August 1, 2022. Ethical approval was deemed not necessary by the institutional board. The data accessed complied with relevant data protection and privacy regulations. The Standards for Quality Improvement Reporting Excellence (SQUIRE)8 were implemented in this study. The study was discussed in advance with the head radiographer of our institution.

Our study included all primary THRs performed in our institution during the specified periods, considering only AP views. All arthroplasty orthopaedic surgeons in our unit were included. Patients who had previously undergone a THR on the contralateral side were accepted. Only elective cases were considered.

Our exclusion criteria comprised of cancelled cases, revision THRs, other radiographic views (frog-leg view, Löwenstein view, and cross-table lateral view9) and traumatic cases resulting in a THR.

Using the Picture Archiving Communication System (PACS) on NIMIS, we retrospectively assessed the templating radiographs for a consecutive series of THRs performed in our unit. TraumaCad® orthopaedic templating software and KingMark® calibration system, both developed by BrainLab©, are utilized in our facility.

We collected the following information for this project: whether a calibration device was used, was the calibration device used appropriately, interval between the preoperative template image and the procedure, and whether the image was repeated.

We looked at five criteria to determine the adequacy of the templating radiograph.10,111.Appropriate usage of the calibration device.122.No pelvic rotation.13,143.The radiograph is centred on the pubic symphysis.14,154.Sufficient femora visibility.11,14,155.Internal hip rotation of 10–15°.15,16

We measured two parameters to help the radiographers determine how much of the femora should be visible.i.The length from the anterior superior iliac spine to the end of the implant = 3.76 cmii.The length from the tip of the greater trochanter to the end of the implant = 2.70 cm

The average of ten faultless radiographs were calculated to determine these values.

The assessment method utilized in this study, formulated by the supervising author based on experience and relevant literature, lacks formal validation. Regrettably, our institution lacks a standardized and validated templating approach for radiographers. This absence underscores a current gap in procedural consistency.

Two authors (BS and AB) conducted a retrospective review of 103 primary THRs from July 28 to September 14, 2021. An intervention was developed after an analysis of the results. The basic guidelines for templating hip radiographs were then detailed in a poster (Fig. S1) created by BS. The poster was created using Canva®17 software. This was accompanied by a presentation to the radiographers in our institution, which involved an educational session on preoperative templating, the benefits and what is required from their department. Both radiographers and radiologists were present for this session. We also presented the findings from our review and highlighted examples of adequate and inadequate radiographs (Figs. S2 and S3). A collaborative conversation on future strategies was undertaken, and the poster was displayed in appropriate locations around the hospital.

An evaluation was conducted 18 weeks post-intervention providing an opportunity for radiographers to incorporate and apply the newly introduced templating guidelines. The second review was again conducted by two authors (BS and MCR). From January 25 to March 11, 2022, 103 primary THRs were evaluated, and the data was studied to determine whether any improvements were made. We hypothesized that the standards of the radiographs would improve due to our intervention. Levels of experience of the authors ranged from senior house officer, senior registrar, and consultant.

2.1

2.1 Data analysis

Statistical analysis was carried out using statistical software R-4.3.3.

3

3 Results

We reviewed a total of 206 templating images (103 pre-intervention and 103 post-intervention). KingMark® was the only calibration device used in this population.

3.1

3.1 Pre-intervention

A median of 55 days (52.5 IQR) was noted for the interval between the templating image and the day of surgery. 74.7 % (n = 77) of preoperative radiographs were taken less than three months before the procedure. 23.3 % (n = 24) were taken within three to six months, while only 1.9 % (n = 2) were taken over 6 months before the procedure.

94 % (n = 97) of the cases used calibration. 73.2 % (n = 71) of these radiographs were deemed adequate (Table 1.1). Of the 26.8 % (n = 26) preoperative radiographs found to be inadequate, 15.4 % (n = 4) were repeated on the day of surgery due to inadequacy. These cases were inadequate for a variety of reasons. 38.5 % (n = 10) radiographs showed malposition of the calibration system. 19.2 % (n = 5) exhibited excessive pelvic rotation. 53.8 % (n = 14) lacked sufficient internal rotation of the hips, and 19.2 % (n = 5) had poor femur visualization. (Fig. 1).

Table 1.1 Pre-intervention adequacy.
Pre-intervention Adequacy Frequency % Of Total
No 26 25.2 %
Yes 71 68.9 %
No Calibration 6 5.8 %
Reasons for inadequacy of templating radiographs.
Fig. 1 Reasons for inadequacy of templating radiographs.
3.2

3.2 Post-intervention

The median between the templating image and the day of the procedure was found to be 84 days (IQR 74). Here, 47.6 % (n = 49) were taken less than three months before the procedure. 33 % (n = 34) were taken within three to six months, while 19.4 % (n = 20) were taken over 6 months before the procedure.

Calibration was used in 100 % of these cases although, 1.9 % (n = 2) cases were not templated for unknown reasons. Out of the total population, 82.5 % (n = 85) of radiographs were deemed adequate (Table 1.2). Of the remaining 17.5 % (n = 18) considered inadequate, 11.1 % (n = 2) were retaken on the day of surgery once again, due to inadequacy. The inadequate cases had various issues, including: 27.7 % (n = 5) with malposition of the calibration system, 61.1 % (n = 11) not centred on the pubis, 38.8 % (n = 7) with excessive pelvic rotation, 27.7 % (n = 5) lacking sufficient hip internal rotation, and 22.2 % (n = 4) with poor femur visualization.

Table 1.2 Post-intervention adequacy.
Post-intervention Adequacy Frequency % Of Total
Yes 85 82.5 %
No 18 17.5 %
3.3

3.3 Statistical analysis

A Chi-Square Test assessed intervention efficacy in both experimental groups. Before interventions, adequacy (yes) and inadequacy (no) frequencies were 71 and 26, respectively. Post-interventions, adequacy increased to 85, and inadequacy decreased to 18. Expected frequencies, assuming no association, were yes = 78 and no = 22.

The analysis yielded a Chi-Square statistic (χ2) of 2.7, df = 3, and a p-value of 0.4384, below the alpha level of 0.05, indicating a significant correlation between interventions and radiograph adequacy. Cramer's V showed an effect size of 0.12, statistically significant but small.

4

4 Discussion

Our institution's templating radiography showed excellent overall adequacy, averaging 78 % during the project. Despite being a national orthopaedic centre with experienced radiographers, a detailed review revealed subpar preoperative templating radiograph quality. Six cases were repeated on the surgery day within a 14-week period, potentially exposing 22 additional patients to unnecessary radiation annually. We aimed to reduce this and achieved a 67 % reduction in repeated radiographs post-intervention.

The main reasons for pre-intervention inadequacy were misplacement/misuse of the KingMark® calibration system, excessive pelvic rotation, insufficient/excessive hip internal rotation, and inadequate visualization of the femora. Inadequate internal rotation of hips had the highest pre-intervention percentage, possibly due to severely arthritic joints being too stiff or painful to rotate properly.

The second most common issue was misplacement of the KingMark® calibration, which all our institution's arthroplasty surgeons use for templating THA radiographs. A recent study showed its superior accuracy compared to the single ball calibration method.4 However, we found that its proper application was not well known among radiologists until we discussed it with them.

Though not always feasible for patients with higher body mass indexes (BMIs), the KingMark® calibration system is user-friendly. It comprises an anterior ball strip with radio-opaque balls fixed to the patient's pelvis using a weight and strap, and a posterior marker with radio-opaque rods arranged in a cross pattern within a flat board. During the radiograph, alignment of one of the five balls with the femoral head and the midline positioning of the rod through the pelvis are essential12 (Fig. S2). If this is not the case, it is recommended that the image be repeated.

Following our intervention, the incorrect calibration placement decreased by 50 % (n = 10 to n = 5). Post-intervention, inadequate images still had similar issues, but there was an increase in pelvic errors: 61.11 % (n = 11) were not centred on the pubis, and 38.8 % (n = 7) showed excessive pelvic rotation. We hypothesized that this increase might be due to insufficient emphasis on pelvic positioning during our discussions with the radiographers and radiologists.

Our institution typically accepts templating radiographs taken within the last six months.18 According to our findings, this is still the case, with an average of 88 % of photos taken less than six months before the procedure.

Overall, the main finding of this study is that the intervention significantly improved the adequacy of preoperative templating radiographs (p-value = 0.44). As is evident in the literature, correct computations require high-quality radiographs.14,15,19 An improper radiograph may respectively underestimate or overestimate femoral neck length and offset.9,14–16 Studies have shown the benefits of templating THR's, with some papers finding a decrease in risk of periprosthetic fractures,20 dislocation21 and even increasing implant longevity.22 Factors affecting accuracy include high BMI, inexperienced surgeons, and severely arthritic joints.13 In some cases, it may be discovered that the diseased hip joint is too arthritic for precise templating. Here, templating the healthy joint is advised despite its inaccuracy.15,23 Ultimately, templating aims to restore each patient's native hip architecture and biomechanics, reducing intraoperative complications and enhancing patient outcomes.20–22

5

5 Limitations

This was a retrospective study; therefore, our data is limited to past collections and is prone to selection bias. A larger population would have also allowed us to better determine the average values of our data and avoid errors from testing a small number of possibly atypical samples.24 A lack of differentiation by surgeon prevents us from assessing individual preferences for templating, radiograph timing, or repeated requests. Additionally, re-examining the data after a longer interval (ideally six months) was not possible due to scheduling constraints.

6

6 Conclusions

In conclusion, our intervention led to a significant correlation between interventions and radiograph adequacy (χ2 = 2.7, df = 3, p = 0.4384 < 0.05). Although the effect size (Cramer's V = 0.12) was statistically significant, its magnitude was small.

We recommend preoperative calibration and templating for all THRs. Future initiatives involve comparing predictability between appropriately and insufficiently templated radiographs post-intervention. Additionally, we aim to develop a formal training program based on our study for surgeons, radiologists, and radiographers in our institution and potentially nationally.

Guardian/patient's consent

No personal information of any patient was utilized in this project. All patients involved in data collection were immediately assigned a key code to ensure anonymity. Any images used, including radiographs, were anonymized, and personal information was obscured.

Ethical statement

Formal ethical approval was deemed not necessary by the institutional board as the study fell into the scope of auditing. The project did not involve anything being done to service users beyond ‘normal’ service provision.

Funding statement

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

CRediT authorship contribution statement

Bisola Salaja: Project administration, Data curation, Writing – original draft, Writing – review & editing, Visualization. Adrian Brennan: Project administration, Methodology, Writing – review & editing. Mihai Rotaru: Data curation, Writing – review & editing. Paul Curtin: Conceptualization, Writing – review & editing, Supervision.

References

  1. , , , , , , . "Hip replacement," the Lancet, vol. 392, no. 2018;10158:1662-1671.
    [Google Scholar]
  2. , . Digital templating in total hip arthroplasty. JBJS. 2004;86(suppl_2):118-122.
    [Google Scholar]
  3. , , , , , . "Accuracy of digital templating in total hip arthroplasty," Am J Orthop (Belle Mead NJ), vol. 40, no. 2011;8:395-398.
    [Google Scholar]
  4. , , , . Templating Hip Arthroplasty. 2019:1857-9655.
    [Google Scholar]
  5. , . TraumaCad: End-To-End Orthopedic Templating Software. 2022
    [Google Scholar]
  6. , et al . Digital versus Conventional Templating Techniques in Preoperative Planning for Total Hip Arthroplasty. 2009:1488-2310.
    [Google Scholar]
  7. , , , . The value of preoperative planning for total hip arthroplasty. J Bone Joint Surg. 1998;80-B(3):382-390.
    [Google Scholar]
  8. , , , , , , . "SQUIRE 2.0 (standards for QUality improvement reporting excellence)," American Journal of medical quality,. . 2015;30:543-549.
    [Google Scholar]
  9. , , . Plain Radiography of the Hip: A Review of Radiographic Techniques and Image Features. 2015:2287-3260.
    [Google Scholar]
  10. , . Preoperative Planning of Total Hip Arthroplasty. 2018
    [Google Scholar]
  11. , . Total Hip Replacement: An Overview. 2018
    [Google Scholar]
  12. , . Orthopedic Calibration Devices: Accurate Calibration in Orthopedic Imaging. 2022
    [Google Scholar]
  13. , , , , , , . The accuracy of digital templating in uncemented total hip arthroplasty. Arch Orthop Trauma Surg. 2019;139(2):263-268.
    [Google Scholar]
  14. , , , . Total Hip Arthroplasty Planning. 2019
    [Google Scholar]
  15. , . Total Hip Replacement: An Overview. 2018
    [Google Scholar]
  16. , , , . Preoperative planning for primary total hip arthroplasty. JAAOS - Journal of the American Academy of Orthopaedic Surgeons. 2005;13(7):455-462.
    [Google Scholar]
  17. , . Free Templates. 2022
    [Google Scholar]
  18. , . 2014
    [Google Scholar]
  19. , , . THA Templating. 2021
    [Google Scholar]
  20. , , , , . The Prevention of Periprosthetic Fractures in Total Hip and Knee Arthroplasty. 1999;vol. 30:191-207.
    [Google Scholar]
  21. , , , , , . Templating for total hip arthroplasty in the modern age. J Am Acad Orthop Surg. 2021;29:e208-e216.
    [Google Scholar]
  22. , , , et al . Femoral offset: anatomical concept, definition, assessment, implications for preoperative templating and hip arthroplasty. Orthop Traumatol Surg Res. 2009;95(3):210-219.
    [Google Scholar]
  23. , , , , , , . Digital templating in total hip arthroplasty using contralateral healthy hip results in decreased accuracy. Acta Orthopædica Belgica. 2021;87:427-433.
    [Google Scholar]
  24. , . The Advantages of a Large Sample Size. 2018
    [Google Scholar]
Show Sections