Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Review Article
2024
:3;
100328
doi:
10.1016/j.jorep.2024.100328

Translate:

Migration of posterior spinal rod to the medial aspect of the thigh: An unusual case report and literature review

Author affiliations
Orthopedic Department, Dow University of Health Sciences, Karachi, Pakistan
Article History
Corresponding author(s)

⁎Corresponding author: Shayan Ali Irfan. shayana990@gmail.com

Article tools · PDF & citations

Abstract

Abstract

The literature encompasses diverse cases of spinal rod migration, ranging from bilateral rod fractures in adult idiopathic scoliosis to anterior and posterior migrations into unexpected anatomical sites. Cases discuss complications, such as gastrointestinal bleeding and acetabular migration, emphasizing the importance of long-term follow-up and vigilant postoperative monitoring. Our study aims to present a unique case report of interbody fusion rod migration following posterior spinal fusion and provide a comprehensive literature review on spinal rod migration cases reported in the medical literature.

A 27-year-old female, who underwent posterior spinal fusion five years ago for a lumbar fracture, presented with pain and swelling in the right thigh. Clinical examination revealed tenderness and a palpable rod in the medial aspect of the distal thigh. Radiographic assessment confirmed rod migration, prompting surgical removal. The case highlights the rarity of complications related to spinal instrumentation.

This study underscores the significance of understanding and addressing complications associated with spinal instrumentation. The presented case, in conjunction with the literature review, contributes valuable insights for clinicians, emphasizing the need for meticulous surgical planning, ongoing research, and heightened awareness to optimize patient outcomes and prevent complications in spinal surgery.

Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Spinal stabilization with instrumentation is a widely used method for spinal traumas, degenerative spinal disease, and sometimes congenital spinal malformations.1 Spinal stabilization through instrumentation, particularly posterior fusion procedures, has emerged as a cornerstone in the management of various spinal conditions, encompassing traumatic injuries, degenerative diseases, and congenital malformations.2,3 The prevalence of spinal fusion surgeries has witnessed a notable surge in recent decades, reflecting the increasing reliance on these procedures for addressing a wide spectrum of spinal pathologies.3,4

Statistics indicate a substantial rise in the number of spinal fusion surgeries globally. According to data from the National Inpatient Sample (NIS) in the United States, the rate of lumbar fusion surgeries increased by over 62% from 2004 to 2015,5 highlighting the growing significance of spinal fusion as a therapeutic intervention.5 This surge is attributed to an aging population, higher incidences of degenerative spinal conditions, and advancements in surgical techniques, making spinal fusion an increasingly viable and effective treatment option.6

Posterior fusion, with its established efficacy in achieving spinal stability, has become a widely adopted approach.7 The utilization of pedicular screws and rod systems has revolutionized the field, providing enhanced structural support and stability. However, with the evolution of spinal instrumentation techniques, there has also been a shift from traditional long rods and hook systems to more refined and targeted approaches.8,9

While posterior fusion procedures are generally considered secure, rare complications, such as rod migration, can present unique challenges.10 Understanding these complications is vital for optimizing patient outcomes, refining surgical techniques, and implementing preventive measures. This case sets the stage for a detailed exploration of such complications, with a focus on a rare case of interbody fusion rod migration, adding valuable insights to the evolving landscape of spinal stabilization. We describe a usual case of a patient with migration of the interbody fusion rod system.

2

2 Case report

A 27-year-old female presented to our outpatient department with a complaint of pain and swelling in the right lower thigh region for several months. Her prior medical record showed an operation done for the first lumber fracture proceeded with posterior spinal fusion, 5-years back. On examination marked tenderness associated with swelling was noted at the medial side of the lower thigh, and a palpable rod was appreciated. The distal sensory-motor functions were intact and the distal dorsalis pedis artery and posterior tibial artery were palpable. The X-rays showed a rod at the medical side of the knee up to 10 cm in length (Fig. 1). The X-ray lumbosacral region showed interbody fusion screws at the first and second lumbar vertebrae (Fig. 2).

X-ray image showcasing a rod positioned at the medial side of the knee, extending up to 10 cm in length.
Fig. 1 X-ray image showcasing a rod positioned at the medial side of the knee, extending up to 10 cm in length.
Lumbosacral X-ray image revealing interbody fusion screws located at the first and second lumbar vertebrae.
Fig. 2 Lumbosacral X-ray image revealing interbody fusion screws located at the first and second lumbar vertebrae.

The patient was counseled. Following the preoperative workup, the patient was shifted to the operation theatre, and the rod was removed from the medial side of the thigh by giving a small incision under fluoroscopic guidance (Fig. 3). Post-operative distal sensory and motor were intact. Post-operatively pain was managed, X-ray images confirmed the removal of the rod, and the patient was discharged following adequate vascular and neurological assessment.

Fluoroscopic-guided surgical procedure capturing the removal of the rod from the medial side of the thigh through a small incision.
Fig. 3 Fluoroscopic-guided surgical procedure capturing the removal of the rod from the medial side of the thigh through a small incision.
3

3 Discussion

Fractures of the spine have been well fixed with pedicular screws and rod system. Previously fusion procedures were being performed with long rods and hook systems.7,10 Posterior fusion procedures are rarely associated with rod migration.7,10 Migration through the retroperitoneal lumbar segment to the pelvis and thigh following an iliopsoas pathway close to iliac and femoral vessels has been reported previously with anterior fusion.11 Nearly half of all migrations are asymptomatic but sometimes can cause severe complications, such as those reported by Gaston et al.,12 who described gastrointestinal bleeding because of rod migration to the internal iliac artery as well as the rectal wall. Gaston et al. reported a sacral fixation rod migration to the acetabulum in which a reoperation was required. Failure of the instrument was due to motion because of non-union of the fracture site.12

Initially, the rod migration is usually asymptomatic, close follow-up with radiographs is required to see the migration of the parts. In the case presented here, interbody fusion was performed 5 years back, rod migrated from the lumber spine to the medial aspect of the distal thigh. Notably, this case highlights a unique pathway of migration through the retroperitoneal lumbar segment to the pelvis and thigh, akin to the iliopsoas pathway near iliac and femoral vessels. Though half of migrations are asymptomatic, severe complications have been reported, including gastrointestinal bleeding and acetabular migration.12

This case underscores the importance of vigilant follow-up, as initial rod migration is often asymptomatic. Radiographic monitoring becomes crucial to detect and assess such migrations. In this instance, failure of instrumentation was attributed to motion caused by non-union of the fracture site, emphasizing the potential complications arising from inadequate fusion.

The presented literature collectively highlights the diverse and unusual complications associated with spinal instrumentation, particularly rod migration, across various patient populations. Dailey et al. describe bilateral rod fracture in adult idiopathic scoliosis, leading to migration into the gluteal region.13 Canavese et al. present a case of late-onset neurological deterioration due to rod migration into the spinal canal in neuromuscular kyphoscoliosis.14 Bayri et al. report distal rod migration in spondylolisthesis, emphasizing the importance of long-term follow-up for late-term complications.15 Soh et al. discuss the rarity of spontaneous rod extrusion through the gluteal skin after rod breakage in adult spinal deformity.16 Gaston et al. describe an uncommon complication of rod migration to the right thigh after scoliosis surgery.12 Kumar et al. highlight early rod migration in lumbar spondylolisthesis and stress the significance of meticulous pre-operative planning.17 Long et al. report on the migration of a spinal fixation rod into the lung in Marfan syndrome.18 Additionally, Dhatt et al. and Dogan et al. contribute unique cases of anterior and posterior rod migration, respectively, to the knee joint and thoracic subarachnoid space.19,20Table 1 briefly highlights the literature presented on this subject.

Table 1 Summary of case reports on spinal rod migration after fusion surgery.
Study Site of Rod Site of Rod Migration Outcomes
Dailey et al.13 Posterior, adult idiopathic scoliosis Gluteal region and proximal posterior thigh Bilateral rod fracture causing pseudarthrosis; migration to the gluteal region, surgically removed without complications.
Canavese et al.14 Posterior, neuromuscular kyphoscoliosis Spinal canal (T9-T10 and T12-L2) Late-onset neurological deterioration; implant migration into spinal canal; decompression achieved through rod removal.
Bayri et al.15 Posterior, spondylolisthesis Retroperitoneal portion Distally migrated rod piece observed; replaced during surgery with posterior spinal fusion; improvement in leg pain.
Soh et al.16 Posterior, adult spinal deformity (ASD) Left gluteal region Rod breakage and caudal migration towards left gluteal region; spontaneous extrusion through gluteal skin; raised awareness about rare occurrence.
Gaston et al.12 Not specified Right thigh Rod migration to right thigh; rod extraction performed; spinal instrumentation after nonunion diagnosis; long-term follow-up emphasized.
Kumar et al.7 Posterior, lumbar spondylolisthesis Not specified (loosening and migration) Early rod loosening and migration after unilateral pedicle screw fixation; revision surgery; symptomatic improvement at 6-month follow-up.
Long et al.18 Anterolateral, adolescent idiopathic scoliosis Left lower lobe of the lung through diaphragm penetration Fixation rod migration cephalad; hardware removal and lung repair; unique case with good results.
Dhatt et al.19 Anterior, Dorsolumbar Spine Knee Joint Anterior spinal rod migration to knee joint; removal resulted in total symptom resolution with normal knee joint movement.
Dogan et al.20 Posterior, Cervical Spine Thoracic Subarachnoid Space Atlantoaxial stabilization with screw-rod technique; rod migration to thoracic subarachnoid space; outlined subsequent management.

In comparison to these cases, our study presents a distinct scenario of rod migration from the dorsolumbar spine to the knee joint, showcasing the potential for implants to migrate to distant sites. The clinical significance of discussing these cases lies in the rare but severe complications associated with spinal instrumentation. The findings underscore the importance of long-term follow-up, meticulous surgical planning, and close monitoring for any signs of implant failure or migration. These cases collectively contribute to the existing body of knowledge, emphasizing the need for heightened awareness among clinicians regarding the potential complications of spinal instrumentation. Understanding the various modes and sites of rod migration is crucial for improving patient outcomes, refining surgical techniques, and implementing effective preventive measures in spinal surgery.

In conclusion, while posterior fusion procedures are generally secure, this case exemplifies the importance of continued surveillance, as late-onset rod migration, though rare, can present significant clinical implications. This underscores the need for clinicians to be vigilant in postoperative follow-ups, ensuring timely detection and intervention in cases of unexpected complications.

4

4 Conclusion

In summary, this case underscores the necessity for vigilant postoperative monitoring in spinal instrumentation patients. The rare occurrence of interbody fusion rod migration from the lumbar spine to the thigh highlights the importance of ongoing clinical follow-up. Comparisons with similar cases emphasize the need for heightened clinician awareness. The study's clinical significance lies in the lessons drawn from diverse cases, emphasizing meticulous surgical planning and long-term vigilance to optimize outcomes and prevent complications. This report serves as a concise yet valuable resource, enhancing awareness of potential complications associated with spinal instrumentation.

Ethical Statement for Solid State Ionics

Hereby, I/insert author name/consciously assure that for the manuscript/insert title/the following is fulfilled.1)This material is the authors' own original work, which has not been previously published elsewhere.2)The paper is not currently being considered for publication elsewhere.3)The paper reflects the authors' own research and analysis in a truthful and complete manner.4)The paper properly credits the meaningful contributions of co-authors and co-researchers.5)The results are appropriately placed in the context of prior and existing research.6)All sources used are properly disclosed (correct citation). Literally copying of text must be indicated as such by using quotation marks and giving proper reference.7)All authors have been personally and actively involved in substantial work leading to the paper, and will take public responsibility for its content.

The violation of the Ethical Statement rules may result in severe consequences.

To verify originality, your article may be checked by the originality detection software iThenticate. See also http://www.elsevier.com/editors/plagdetect.

I agree with the above statements and declare that this submission follows the policies of Solid State Ionics as outlined in the Guide for Authors and in the Ethical Statement.

Consent to participate

Consent was obtained from the patients regarding the publication of the case. The patient has no objection to reporting the case unless the identity of the patient is revealed.

Consent for publication

A written consent of the patient was obtained regarding the publication of the case. Patient declare no objection to publication if the identity of the patient is no revealed.

Data availability statement

Data sharing is not applicable to this article as no datasets were generated or analysed during the current study.

Declaration of funding

None.

Submission declaration

This study, approved by all the authors has not been published previously nor under consideration for publication elsewhere.

CRediT authorship contribution statement

Asif Ali: Conceptualization, Methodology, Software, Writing – review & editing. Badar Uddin Sahito: Conceptualization, Methodology, Software, Supervision. Shayan Ali Irfan: Data curation, Writing – original draft, Writing – review & editing. Jagdesh Kumar: Visualization, Investigation. Huzaifa Soomro: Software, Validation.

Declaration of generative AI and AI-assisted technologies in the writing process

During the preparation of this work, the author used the CHATGPT 3.5 version to assess the language and grammar. After using this tool/service, the author reviewed and edited the content as needed and took full responsibility for the content of the publication.

References

  1. , , , et al . Hybrid instrumentation in lumbar spinal fusion: a biomechanical evaluation of three different instrumentation techniques. Global Spine J. 2017;7(1):47-53.
    [Google Scholar]
  2. , , , , . A meta-analysis comparing ALIF, PLIF, TLIF and LLIF. J Clin Neurosci. 2017;44:11-17.
    [Google Scholar]
  3. , , , et al . Long-segment posterior cervical decompression and fusion: does caudal level affect revision rate? J Neurosurg Spine. 2021;35(1):1-7.
    [Google Scholar]
  4. , , , , , . Meta-analysis of instrumented posterior interbody fusion versus instrumented posterolateral fusion in the lumbar spine. J Neurosurg Spine. 2011;15(3):295-310.
    [Google Scholar]
  5. , , , , , , . Trends in lumbar fusion procedure rates and associated hospital costs for degenerative spinal diseases in the United States, 2004 to 2015. Spine. 2019;44(5):369-376.
    [Google Scholar]
  6. , , , et al . Spine deformity surgery in the elderly: risk factors and 30-day outcomes are comparable in posterior versus combined approaches. Neurol Res. 2017;39(12):1066-1072.
    [Google Scholar]
  7. , , , et al . Orthostatic hypotension following posterior spinal fusion surgeries for spinal deformity correction in adolescents: prevalence and risk factors. BMC Muscoskel Disord. 2021;22(1):1039.
    [Google Scholar]
  8. , , . Dorsale Korrekturspondylodese der idiopathischen Adoleszentenskoliose [Posterior instrumented correction and fusion of adolescent idiopathic scoliosis] Operative Orthopadie und Traumatologie. 2024;36(1):21-32.
    [Google Scholar]
  9. , , , et al . Implant failure of pedicle screws in long-segment posterior cervical fusion is likely to occur at C7 and is avoidable by concomitant C6 or T1 buttress pedicle screws. J Clin Neurosci. 2019;63:106-109.
    [Google Scholar]
  10. , , , et al . Comparison of perioperative complications between anterior fusion and posterior fusion for osteoporotic vertebral fractures in elderly patients: propensity score-matching analysis using nationwide inpatient database. Clin Spine Surg. 2020;33(10):E586-E592.
    [Google Scholar]
  11. , , , , . How to deal with this complication: intraoperative anterior cage migration in L5-S1 resolved with a lumbar hybrid fusion technique. Cómo afrontar esta complicación: migración intraoperatoria de la caja anterior en L5-S1 resuelta con una técnica de fusión lumbar híbrida. Cir Cir. 2021;89(5):669-673.
    [Google Scholar]
  12. , , , , , . Migration of the anterior spinal rod to the right thigh, a rare complication of anterior spinal instrumentations: a case report and a literature review. Case Rep Orthop. 2015;2015
    [Google Scholar]
  13. , , , . Implant failure following posterior spinal fusion-caudal migration of a fractured rod: case report. Spine Deform. 2015;3(4):380-385.
    [Google Scholar]
  14. , , , et al . Rod migration into the spinal canal after posterior instrumented fusion causing late-onset neurological symptoms. J Pediatr Orthop. 2017;37(1):e10-e14.
    [Google Scholar]
  15. , , , , , . Migration of rod into retroperitoneal region: a case report and review of the literature. Korean J Spine. 2014;11(4):241-244.
    [Google Scholar]
  16. , , , , . Migration and spontaneous extrusion of a lumbar spinal fusion rod from the gluteal region. Cureus. 2021;13(12)
    [Google Scholar]
  17. , , , , . Early loosening of spinal rod in a case of degenerative grade 1 spondylolisthesis treated with unilateral pedicle screw fixation and transforaminal cage for interbody fusion. J Orthop Case Rep. 2017;7(4):6-9.
    [Google Scholar]
  18. , , , , . Migration of a lumbar spinal fusion rod into the posterolateral knee: a case report. Spine. 2021;46(3):E213-E215.
    [Google Scholar]
  19. , , , , , . Migration of anterior spinal rod from the dorsolumbar spine to the knee: an unusual complication of spinal instrumentation. Spine. 2010;35(7):E270-E272.
    [Google Scholar]
  20. , , , , . Rod migration to the thoracic subarachnoid space after C1-2 instrumentation: a case report and literature review. Orthop Surg. 2017;9(1):129-132.
    [Google Scholar]
Show Sections