Research Article
2023
:2;
100213
doi:
10.1016/j.jorep.2023.100213

Translate:

Osteochondral defect creation in animal model with brad point drill bits - A preliminary study

Author affiliations
Division of Surgery, ICAR-Indian Veterinary Research Institute, Izatnagar, Bareilly, Uttar Pradesh, India
Division of Pathology, ICAR-Indian Veterinary Research Institute, Izatnagar, Bareilly, Uttar Pradesh, India
Article History
Corresponding author(s)

∗Corresponding author: S. Amitha Banu. aamianchu@gmail.com

∗∗Corresponding author: Swapan Kumar Maiti. swapanivri@gmail.com

Article tools · PDF & citations

Abstract

Abstract

The shift from manual to machine-based operations has also affected the creation of cartilage defect models. Manual drilling lacks precision and consistency compared to power drills, which offer controlled speed and depth. Moreover, manual burrs may produce defects with irregular edges and uneven surfaces. We introduce a superior method utilizing a power drill with a brad point bit to overcome these limitations, ensuring precision, consistency, and ergonomics.

Our innovative approach uses a brad point drill bit to generate cartilage repair animal models. Tissue sections on day 90 were stained using Hematoxylin and Eosin, Safranin-O, and Masson's trichrome to assess proteoglycan and collagen contents. In contrast, differentiation of hyaline cartilage was evaluated using RGB trichrome staining.

This technique can be considered refined compared to conventional methods. The spur-cutting edges bring down splintering, resulting in a smooth, clean defect. The wide flute in the drill bit helps in the smooth and continuous outflow of debris without plugging into the defect. The histological and radiographic findings demonstrated the suitability of these models for proficiently creating and assessing cartilage regeneration over 90 days.

Although preliminary findings are promising, further studies will be helpful to standardize and establish this technique. This proof of concept paper provides a foundation for future studies that aim to compare the animal model with other existing models, emphasizing the need for further investigation.

Keywords

  • Cartilage regeneration
  • Osteochondral defect
  • Rabbit model
  • Animal model
  • Drill bit
  • Brad point drill bit
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

An osteochondral defect refers to a defect in the cartilage and a portion of the underlying subchondral bone. The knee and shoulder joints are the most commonly used joints to study osteochondral or full-thickness cartilage defects.1 There are various chemically induced or surgically-created models for osteoarthritis. The size of the defect ranges from 1-5 mm in depth and 2–5 mm in diameter.2 In cartilage regeneration studies, an osteochondral defect of >3 mm diameter is considered a critical size defect (CSD).3 Moreover, the size of the defect depends on the skeletal maturity; therefore, larger defects are created in older animals due to their wide femoral condyle.2

The manual technique for creating a full-thickness osteochondral defect in the femoro-patellar groove includes using a trephine, drill bit, or biopsy punches.4 The manual techniques for creating cartilage defects are associated with several drawbacks. Any bias in the results due to the variability in osteochondral defects should be avoided. The errors can be minimized to an extent by employing the same operator and instruments throughout the surgeries. The power of drilling and the time gap between the procedures are major determinants in maintaining uniformity. The wobbling of instruments is a major limitation of manually driven instruments like hand chucks, K wire, etc. Moreover, the anisotropic structure of articular cartilage will give a variable amount of resistance while penetrating deep into the structure. The use of biopsy punches to create osteochondral defects is associated with futile penetration of the subchondral bone, leading to inappropriate chondral defects.5

In today's fast-paced world, where efficiency and productivity are paramount, machinery is gradually replacing manual operations. This shift is also evident in creating cartilage defect models, where manual drilling is being replaced with more advanced techniques. In line with this trend, we are delighted to introduce a novel approach for creating cartilage defects utilizing a brad point drill bit.

2

2 Materials and methods

The rabbits were anesthetized using a combination of xylazine at 5 mg/kg body weight and ketamine at 50 mg/kg body weight via the intramuscular route. The left knee was operated on under sterile surgical conditions. The skin over the left knee joint was aseptically prepared. A parapatellar skin incision was made medially over the left knee joint. The joint capsule was exposed and incised to dislocate the patella laterally. The limb was flexed to 90° to exteriorize the patellar groove. Using an electrically driven brad point drill bit, a 4 mm diameter and 5 mm depth osteochondral defect was created in the central patellar groove of the left knee joint. The depth control was achieved by drilling in a controlled manner. The patella was repositioned, and the joint capsule was sutured using 4–0 polyglactin 910. Routine suturing with 2–0 nylon was performed to close the skin. Postoperatively, ceftriaxone (30 mg/kg IM) and meloxicam (0.2 mg/kg IM) were administered for five consecutive days. Daily Povidone iodine dressings were applied until the wound healed. Animals were individually caged with unrestricted access to food and water throughout the study.

The post-operative radiographs of the test joints were captured in an anteroposterior view with extended joint positions. Radiographic exposure factors were 40 kVP, 6 mAs, and 75 cm FFD. Following euthanasia, the tissue samples were harvested on day 90 and fixed in a 10% neutral buffer. A decalcification process using the Gooding and Stewart solution was carried out. Paraffin blocks were created from the tissue samples for histopathological assessment. The sections were stained using various stains, including Hematoxylin and Eosin (H&E), Safranin-O, Masson's trichrome and RGB trichrome.6 Safranin-O staining and Masson's trichrome staining were used to assess proteoglycan and collagen content, respectively.6,7 RGB trichrome staining was used to distinguish the type of regenerated cartilage. .8 Visualization of stained samples was conducted using a polarized light microscope.

3

3 Results

The surgical defects were successfully created on the left knee joint of the rabbits. We have characterized an osteochondral defect rabbit model using a brad point drill bit operated in a controlled manner (Fig. 1). The controlled drilling technique ensured accurate depth control during the defect creation process. The patella was repositioned, and the joint capsule and skin were sutured securely. The technique of controlled drilling played a pivotal role in maintaining accurate depth control throughout the defect formation process. Following the procedure, the patella was repositioned, and meticulous suturing of the joint capsule and skin was performed to ensure secure closure. Notably, the anteroposterior radiograph obtained demonstrated the establishment of a comprehensive full-thickness osteochondral defect by utilizing a brad point drill bit.

(a) Exposed trochlear groove. (b) 4 mm brad point drill bit (inset figure) placed perpendicular to the mid-trochlear groove for osteochondral defect creation. (c) 4 mm full-thickness osteochondral defect. (d) Anterio-posterior radiographic view of the full-thickness osteochondral defect (arrow). Scan the QR code to view the procedure.
Fig. 1 (a) Exposed trochlear groove. (b) 4 mm brad point drill bit (inset figure) placed perpendicular to the mid-trochlear groove for osteochondral defect creation. (c) 4 mm full-thickness osteochondral defect. (d) Anterio-posterior radiographic view of the full-thickness osteochondral defect (arrow). Scan the QR code to view the procedure.

The H&E staining revealed a few scattered chondrocytes with no discernible clustering in the regenerated tissue (Fig. 2). The regenerated surface displayed an irregular appearance compared with the surrounding healthy tissue. The demarcation of the tide mark from the underlying calcified matrix was obscure. Safranin-O staining unveiled inadequate proteoglycan deposition and was depicted by a subtle orange colour. Fibroblast proliferation was notably increased, indicating the development of fibrocartilage tissue, and the uniform green tint suggested the absence of glycosaminoglycan deposition. Masson's trichrome staining showcased diminished collagen deposition in the cartilage matrix, denoted by the blue coloration within the regenerated tissue. Notably, the RGB staining highlighted areas of calcified fibrocartilage formation with few chondrocytes. The histological findings strongly suggest that the regenerated tissue comprises a poor-quality cartilage matrix. These observations aligned with our hypothesis that our technique facilitates the creation of full-thickness osteochondral defects over 90 days.

Histopathology findings on day 90. (A) Safranin-O staining: The proteoglycan deposition is very less (black asterisk) due to the low number of chondrocytes (yellow arrow) (orange coloured area indicates proteoglycan deposition). The homogenous green colour reveals the absence of proteoglycan deposition (red asterisk). More fibroblasts (red arrow) are present, indicating fibrocartilage tissue formation. (B) Masson's trichrome staining: The blue-coloured area indicates collagen deposition. However, the deposition area is less (yellow asterisk), and the more intense colour indicates the scanty deposition of proteoglycan in regenerated tissue. In addition, the red colour (yellow arrow) indicates the presence of calcified collagen deposition. More area of vascularity (red arrow) is also observed, which is also an indication of abnormal regeneration. (C) RGB trichrome: This staining technique is very useful in detecting fibrocartilage formation. The greenish stained area indicates the calcified fibrocartilage formation (black asterisk). The cluster of chondrocytes (very less number, red arrow) is surrounded by purple stained territorial matrix indicating the normal hyaline cartilage tissue. Here, a uniform fibrocartilage formation is identified. (D) H&E staining: The number of chondrocytes in regenerated tissue is much less (black asterisk) and is arranged randomly without cluster or column formation. The regenerated surface is irregular, and the tide mark zone is vague and irregular (yellow arrow). (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
Fig. 2 Histopathology findings on day 90. (A) Safranin-O staining: The proteoglycan deposition is very less (black asterisk) due to the low number of chondrocytes (yellow arrow) (orange coloured area indicates proteoglycan deposition). The homogenous green colour reveals the absence of proteoglycan deposition (red asterisk). More fibroblasts (red arrow) are present, indicating fibrocartilage tissue formation. (B) Masson's trichrome staining: The blue-coloured area indicates collagen deposition. However, the deposition area is less (yellow asterisk), and the more intense colour indicates the scanty deposition of proteoglycan in regenerated tissue. In addition, the red colour (yellow arrow) indicates the presence of calcified collagen deposition. More area of vascularity (red arrow) is also observed, which is also an indication of abnormal regeneration. (C) RGB trichrome: This staining technique is very useful in detecting fibrocartilage formation. The greenish stained area indicates the calcified fibrocartilage formation (black asterisk). The cluster of chondrocytes (very less number, red arrow) is surrounded by purple stained territorial matrix indicating the normal hyaline cartilage tissue. Here, a uniform fibrocartilage formation is identified. (D) H&E staining: The number of chondrocytes in regenerated tissue is much less (black asterisk) and is arranged randomly without cluster or column formation. The regenerated surface is irregular, and the tide mark zone is vague and irregular (yellow arrow). (For interpretation of the references to colour in this figure legend, the reader is referred to the Web version of this article.)
4

4 Discussion

Using a hand-operated drill for osteochondral defect creation lacks precision and consistency. Unlike powered drills, which offer controlled speed and depth, hand-operated drills heavily rely on the operator's manual dexterity and strength. This human factor introduces a significant variation in the size and shape of the created defects, leading to inconsistent results and difficulty in accurately comparing outcomes between different experimental subjects. Hand-operated burrs may produce defects with irregular edges and uneven surfaces, which do not accurately replicate the natural morphology of osteochondral defects. It also has limited control over important parameters such as speed, force, and duration of the drilling process. These factors can significantly influence the size and quality of the defect and may vary between experimental sessions.

The tips of the commonly used drill bits are conical-shaped. Conical drills, also known as twist drills, have a spiral flute design and a conical tip. Conical drills can be used for various materials, including wood, metal, plastic, and masonry, depending on the bit's material and design. They are versatile, widely available, and allow rapid drilling. However, conical drills might have a bit of wandering at the initial drilling point, which can affect accuracy. Using conical drills on delicate surfaces like articular cartilage can cause splintering. Tear-out is more common while using conical drill bits on articular cartilage.9

Brad point drill bits are commonly used for woodworking applications where precision and clean cuts are essential. The average articular cartilage thickness in rabbits is 0.3 mm.10 They are especially suitable for drilling into delicate structures like cartilage, as they minimize splintering. The pointed tip and spurs ensure accurate hole placement and prevent the bit from drifting. Moreover, they can produce clean and splinter-free defects.11

The osteochondral defect creation using an electric power drill machine and brad point drill bits can be considered a refined technique compared to the conventional methods. The drill bit is constructed extremely sharp with a centered tip that permits the exact positioning of the defect and an accurate start.11 It has fine shoulder cutters with precise edges that help create defects without tears. The spur-cutting edges bring down splintering, resulting in a smooth, clean defect. The wide flute in the drill bit helps in the smooth and continuous outflow of debris without plugging into the defect. The shank is designed in a straight, round manner that allows for strong chucking into the power drill machine and prevents sliding and slipping during its application.

A constant yet controlled power can be delivered using the power drill machine. The so-formed defects exhibited uniform dimensions (diameter and depth). The procedure was time-saving and narrowed the chances of thermal necrosis. In addition, enhanced precision was a chief benefit of this technique. The radiographic view of the osteochondral defect is quite explicit, so the evaluation of healing in the post-treatment days would be unchallenging. Furthermore, operator errors are drastically reduced, thereby enhancing accuracy.

5

5 Conclusion

In brief, the present technique may be used to generate precise osteochondral defects in different animal models. The histological and radiographic findings demonstrated the suitability of these models for proficiently creating and assessing cartilage regeneration over 90 days. This proof of concept paper provides a foundation for future studies that aim to compare the animal model with other existing models, emphasizing the need for further investigation.

Author statement

MM, ABS, and KS: Conceptualization, investigation, and initial draft writing. MKM, EK, MM, SS: Writing and editing. KPS, KS, and SKM: Supervision. All authors listed have made a substantial, direct, and intellectual contribution to the work and approved it for publication.

Funding statement

This research received no specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Informed consent

Not applicable to this study.

Institutional ethical committee approval (for all human studies)

Not applicable to this study.

Ethical approval (for animal study)

All the methods and experimental protocols were carried out according to the guidelines approved by the Institute Animal Ethics Committee (IAEC) of the Indian Veterinary Research Institute (ICAR-IVRI), Izatnagar, Bareilly, Uttar Pradesh.

Availability of data and materials

The authors declare that the data supporting the findings of this study are available within the article.

References

  1. , . Animal models of osteoarthritis: comparisons and key considerations. Vet Pathol. 2015 Sep;52(5):803-818.
    [Google Scholar]
  2. , , , et al . A rabbit femoral condyle defect model for assessment of osteochondral tissue regeneration. Tissue Eng C Methods. 2020 Nov;26(11):554-564.
    [Google Scholar]
  3. , , , et al . Animal models of cartilage repair. Bone Joint Res. 2014 Apr 2;3(4):89-94.
    [Google Scholar]
  4. , , , et al . Repair of large osteochondral defects in rabbits using porous hydroxyapatite/collagen (HAp/Col) and fibroblast growth factor-2 (FGF-2) J Orthop Res. 2010 May;28(5):677-686.
    [Google Scholar]
  5. , . Histological evaluation of osteochondral defects: consideration of animal models with emphasis on the rabbit, experimental setup, follow-up and applied methods. Cells Tissues Organs. 2002;171(4):229-240.
    [Google Scholar]
  6. , . Chemical basis for the histological use of safranin O in the study of articular cartilage. J Bone Joint Surg Am. 1971 Jan;53(1):69-82.
    [Google Scholar]
  7. , . Some histological methods: trichrome stainings and their preliminary technique. J Tech Methods. 1929;12:75-90.
    [Google Scholar]
  8. , , , , . A novel RGB-trichrome staining method for routine histological analysis of musculoskeletal tissues. Sci Rep. 2020 Oct 7;10(1)
    [Google Scholar]
  9. , , . Analysis of drilling tool life-a review. Int J Mech Eng Robot Res. 2015 Jan 1;4(1):523.