Recurrent hemarthrosis of the knee after remote fracture fixation: A report of two cases
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Two patients presented with recurrent hemarthrosis and limited range of motion after remote ORIF of peri-articular knee fractures. Symptoms resolved temporarily with aspirations, which were negative for infectious or immune etiologies, but subsequently reaccumulated. Neither radiographs nor MRI definitively demonstrated intra-articular extension of the hardware. After arthroscopically-assisted removal of hardware (ROH), there was resolution of symptoms and functional improvement.
With recurrent hemarthrosis of unknown etiology after ORIF of peri-articular knee fractures, the authors recommend consideration of removal of hardware that may project intra-articular. Arthroscopy allows direct visualization of the prominent hardware, articular cartilage, and other intra-articular soft tissues that may be damaged.
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
Hemarthrosis of the native knee joint is often related to acute trauma. Common causes include patellar dislocation or fracture, cruciate ligament injury, and meniscal tears, all of which may injure branches of the geniculate arteries.1 In the absence of trauma, common causes of spontaneous hemarthrosis are hereditary clotting disorders,2 or may be a complication of anticoagulant therapy.3 Treatment in these cases is either replacement of the deficient clotting factor or cessation and reversal of the anticoagulant.3,4 Hemarthrosis is a painful manifestation of intra-articular damage and often causes restricted range of motion. This is multifactorial due to the effusion present, and heme, a by-product of blood breakdown, and other proinflammatory mediators present in blood are known to negatively interact with the articular surface to accelerate degenerative changes within the joint.5 In most cases, hemarthrosis due to acute injury or in the post-operative setting will resolve with conservative management. However, if the inciting problem does not resolve, as in the case of prominent intra-articular hardware, hemarthrosis can become a source of continued pain and cartilage degeneration.
We present two cases of chronic hemarthrosis as a complication of remote fracture fixation around the knee with no clear evidence of intra-articular hardware based on pre-operative imaging. In neither case was it obvious until the time of arthroscopy that hardware was prominent within the intra-articular space, despite appropriate pre-operative imaging investigation. We discuss these cases to highlight the occurrence of chronic hemarthroses as a manifestation of intra-articular prominence of hardware in the knee joint.
Statement of Informed Consent: All patients presented in these cases signed consent forms that included an acknowledgement that data concerning their condition and surgical procedure could be used for research purposes.
2 Case 1
A 61-year-old woman presented to clinic for chronic left knee pain and swelling. She underwent open reduction (ORIF) for a transverse patella fracture four years prior, with two partially-threaded 4.0mm cannulated screws at an outside hospital (OSH). She completed the recommended course of physical therapy (PT) for her injury and was informed that the fracture had fully healed. Six months prior to presenting to the sports medicine clinic, she reported insidious onset of symptoms. She noted pain with stairs and walking, and tightness around the knee. She was treated with two steroid injections and one Synvisc injection at an OSH without relief. Radiographs and MRI were obtained by her primary care physician (PCP). Radiographs revealed well-maintained joint spaces and evidence of the prior patellar fracture hardware. MRI demonstrated a large joint effusion and otherwise normal knee anatomy. Evaluation of the relationship between the patellar hardware and the articular surface was limited by artifact. (Fig. 1). Her PCP referred the patient to an arthroplasty surgeon who did not deem her a candidate for replacement. She continued with PT, who then referred her to a sports medicine surgeon given her lack of improvement. On clinical exam, she was found to have a large effusion, decreased ROM compared to the right knee (0°–120° vs 0°–105°), as well as crepitus and medial and lateral patellar facet tenderness. Her ligamentous exam was stable. An arthrocentesis yielded 55mL of serosanguinous fluid which was sent for gram stain, cell count, crystals, Lyme titers, and culture, all of which were negative. While there was no clear radiographic or MRI evidence of hardware within the joint, the failed conservative management and continuing symptoms resulted in a discussion of diagnostic arthroscopy and possible ROH. During diagnostic arthroscopy of the patellofemoral joint, a trough in the medial femoral condyle that articulated with the patella was noted with flexion of the knee (Fig. 2). On the patellar side, although there was no visible screw, there was an area of friable, fissured cartilage that articulated with the trough noted in the medial femoral condyle (Fig. 2). The articular cartilage did not appear malreduced, and no fracture line was noted. The frayed cartilage was gently debrided with the arthroscopic shaver. There was hemosiderin staining of the synovium consistent with chronic hemarthroses (which was gently debrided), but otherwise normal knee anatomy. The retained screws were then removed through a small incision at the inferior pole of the patella. Post-operatively, the patient remained weight bearing as tolerated with the knee locked in extension for four weeks. She began PT and gradually progressed to discontinuation of the brace at two weeks. The patient was seen at 10 days, four weeks, three months and six months post-operatively. She noted symptom resolution at her first post-operative visit, and after therapy was able to walk and do stairs without pain. At 6 months post-op she was released from PT and follow-up without hemarthrosis recurrence and with dramatic symptom improvement.


3 Case 2
A 29-year-old man presented for chronic right knee pain and pain with ambulation. He sustained a right open tibial shaft fracture as a pedestrian struck by a motor vehicle seven years prior, and underwent ORIF with intramedullary nail at an OSH. In the six months prior to presenting to clinic he experienced cyclic episodes of swelling and increasing pain. This eventually progressed to persistent swelling and an inability to ambulate at which time he presented to the emergency department. During clinical exam he could only range his knee from 45° to 60°. A large effusion was present, and he was tender to palpation throughout. Radiographs demonstrated a healed tibial shaft fracture in anatomic alignment, hardware in place without evidence of migration, and well-maintained joint spaces (Fig. 3). He followed up in trauma clinic where an MRI was obtained of the affected knee revealing a stable osteochondral (OCD) lesion of the medial tibial plateau. He was then referred to sports medicine, where the possibility of a prominent screw was noted upon further imaging review. (Figs. 3 and 4). Due to the COVID-19 pandemic it was suggested he undergo serial aspirations of the knee for pain relief, until an elective surgery could be scheduled. However, after his last aspiration he was unable to walk despite the removal of 50mL of serosanguinous fluid, and an arthroscopy was scheduled for evaluation of possible prominent hardware and medial tibial plateau OCD. Of note, prior to surgery we counseled the patient that hemarthroses are not a reported presentation of stable, chronic OCDs. During arthroscopic exam, the knee joint was found to be diffusely hemosiderin-laden with synovitis (Fig. 5). The cartilage appeared intact on the tibial plateau and in all compartments, with grade 1 changes throughout but no evidence of OCD noted. A screw tip was palpated by the arthroscopy probe beneath the posterior horn of the lateral meniscus projecting beyond the cortex of the posterosuperior tibia and into the capsule and synovium. The remainder of the diagnostic arthroscopy demonstrated normal anatomy. Synovectomy with the radiofrequency ablation device and chondroplasty were performed, and the tibial screw was removed via direct dissection. The patient was discharged to home with instructions to bear weight as tolerated. He followed up post-operatively at 14 days with complete symptom resolution at that time. He was then seen at six weeks with continued pain relief and maintained ROM, and released from follow-up care.



4 Discussion
Peri-articular fractures are often fixed with hardware in close proximity with the joint, with care taken to ensure hardware remains extra-articular, or countersunk if an intra-articular approach is utilized. Hardware placement is verified intra-operatively using fluoroscopy and direct visualization when available. While screw placement is verified on fluoroscopy, implants can become prominent from screw migration or further degeneration of the adjacent articular cartilage.
If there is hardware penetrating the articular cartilage or within the intra-articular space, there are limitations to what can be confirmed with imaging. Radiographs may identify placement of hardware, but given the limited two-dimensional nature of radiographs, they may not clearly identify how close the hardware is to the surface of the bone. Radiographs cannot visualize the articular cartilage or soft tissue that may be abutting the hardware. MRI is more sensitive to visualize loosening of hardware, and can better detail soft tissues in the joint, but can be distorted by metal artifact6,7 As the rate of orthopedic implants has continued to climb,6 evolving imaging techniques, such as pre-polarized MRI, view angle tilt imaging, single point imaging, and projection reconstruction have been developed to suppress the distortion created by metal within the body.6 However, many of these new techniques have not made their way into common practice. As such, it is important that surgeons understand the limitations of common MRI sequences in the presence of orthopedic implants.
In cases of recurrent knee hemarthrosis after remote fracture fixation, when other causes of hemarthroses have been ruled out, we suggest considering ROH that may be interacting with soft tissue and/or articular cartilage, even if this is not readily confirmed by radiographs or MRI. An arthroscopic approach allows for careful examination of the knee anatomy, including the bony surfaces, articular cartilage, menisci, ligaments, and other intra-articular soft tissues, with probing or visual examination of hardware. These two cases provide examples of such occurrences manifesting in separate compartments of the knee, with satisfactory symptom resolution following arthroscopic-assisted removal of hardware.
Ethics statement
The authors of this article, “Recurrent Hemarthrosis of the Knee After Remote Fracture Fixation: A Report of Two Cases” ensure that it is an orginally written work. If the authors have used the work and/or words of others, they has been appropriately cited or quoted and permission has been obtained where necessary.
Funding statement
No funding sources were used for this paper.
Disclosures
Paul S Whiting, MD is a board or committee member for Orthopedic Trauma Association.
Andrea M. Spiker, MD is a board or committee member for the American Orthopedic Association, American Orthopedic Society for Sports Medicine and the Arthroscopy Association of North America. She is on the editorial or governing board for Arthroscopy and the Video Journal of Sports Medicine/American Journal of Sports Medicine. She is a paid consultant for Stryker.
Guardian/patient's consent
Each patient included in the article, “Recurrent Hemarthrosis of the Knee After Remote Fracture Fixation: A Report of Two Cases”, have granted permission for use of their information/data. This permission was included in the surgical consent that was signed prior to their surgical procedures.
CRediT authorship contribution statement
Elizabeth H.G. Turner: contributed to, Conceptualization, Data curation, Investigation, Methodology, Writing – original draft. Paul S. Whiting: contributed to, Conceptualization, Supervision, Validation, Visualization, Writing – review & editing. Jace J. Heiden: contributed to, Data curation, Writing – review & editing. Andrea M. Spiker: contributed to, Conceptualization, Data curation, Project administration, Validation, Visualization, Writing – review & editing.
References
- Occult Intra-articular knee injuries in children with hemarthrosis. Am J Sports Med. 2014;42(7):1600-1606.
- [Google Scholar]
- Hemarthrosis associated with sodium warfarin therapy. Arthritis Rheum. 1976;19(1):98-102.
- [Google Scholar]
- Factor VIII replacement is still the standard of care in haemophilia A. Blood Transfus. 2019;17(6):479-486.
- [Google Scholar]
- A review of current management of knee hemarthrosis in the non-hemophilic population. Cartilage 2020
- [Google Scholar]
