Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Case Report
2025
:4;
100459
doi:
10.1016/j.jorep.2024.100459

Translate:

Stress-shielding mimicking recurrence in a paediatric left proximal femur unicameral bone cyst with pathological fracture – A case report

Author affiliations
KK Women’s and Children’s Hospital, Singapore
School of Medicine (National University of Singapore), Singapore
Article History
Corresponding author(s)

⁎Corresponding author: Erel Kane Tan Yun En. ereltan10000@gmail.com

Article tools · PDF & citations

Abstract

Abstract

Simple/unicameral bone cyst (SBC) is a common bone lesion found especially in the pediatric population often diagnosed incidentally on X-ray or due to a pathological fracture. Most of such fractures require curettage with or without fixation depending on fracture stability. Those that require fixation may pose an issue to post-operative surveillance of cyst recurrence due to the stress shielding phenomenon.

We present a case of a pathological subtrochanteric femoral fracture on the background of an SBC in a 6-year-old boy. Curettage of the lesion and surgical fixation of the femur were performed for the patient with favourable outcomes.

Pathological fractures of SBCs that need fixation should be have a less rigid fixation with the intent of allowing better visualization/monitoring under CT scan to better allow surveillance of cyst recurrence, and also reduce the effect of stress shielding.

Keywords

  • Simple bone cyst
  • Stress shielding
  • Pathological fracture
  • Recurrence
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

SBCs are intraosseous lesions of unknown etiology and the most common benign bone lesion in children.1 They are fluid-filled and predominantly metaphyseal, most commonly in the proximal humerus followed by the proximal femur. These cysts can lead to repeated pathological fractures, and subsequently symptomatic malunion. Therefore, the main objectives of management are reducing such risks, improving cyst healing, and monitoring for recurrence.2

However, in pathological fractures that require surgical fixation, stress shielding may be a cause of interference with these objectives. Stress shielding is a biomechanical effect of reduction in bone density which metallic implants have on fracture healing.3 According to Wolff’s Law,4 implants can decrease the physiological loading in a particular area of bone resulting in bone resorption and atrophy, eventually leading to decreased bone density and subsequently osteopenia. There is also a positive relationship between the length of time the implant is in place and the magnitude of bone loss due to this phenomenon, in turn corresponding to a lower potential for the bone to recover.5

Moreover, stress shielding may mimic the recurrence of a bony cyst radiographically, making post-operative management and surveillance difficult and a source of confusion for decision-making. This occurrence is described in detail below.

We herein describe a case of a pathological fracture secondary to an SBC in a 6-year-old boy which was effectively managed with curettage, local adjuvants, and internal fixation.

2

2 Case report

A 6-year-old boy presented to the Children’s Emergency with severe left knee pain after a fall while skateboarding overseas 4 days prior and had been unable to ambulate since. Significantly, this was on a background of occasional mild left knee pain for the last 1–2 years associated with abnormal gait.

3

3 Clinical findings

On clinical examination, there was significant tenderness in the left hip and limited range of motion (ROM) due to severe pain. He was able to range his left knee actively and there was no neurovascular deficit noted in the left lower limb. He was otherwise well, non-toxic, and afebrile.

4

4 Diagnostic assessment

Initial lab results revealed elevated CRP 18.2mg/L and ESR 31mm/hr, but normal white cell count (WCC) of 6.0 x 109/L.

An X-ray of the pelvis showed a lucent, mildly expansile lesion in the left proximal femur (Fig. 1a and b). There was a narrow zone of transition and the presence of cortical thinning, but no periosteal reaction or cortical breach.

The left femur on plain radiograph showing a proximal lytic lesion with pathological fracture in the a) AP view, and the b) lateral view; And on coronal magnetic resonance imaging showing a c) T1-weighted hypointense and d) T2-weighted hyperintense lesion in the left proximal femur with e) post-contrast rim enhancement.
Fig. 1 The left femur on plain radiograph showing a proximal lytic lesion with pathological fracture in the a) AP view, and the b) lateral view; And on coronal magnetic resonance imaging showing a c) T1-weighted hypointense and d) T2-weighted hyperintense lesion in the left proximal femur with e) post-contrast rim enhancement.

Magnetic resonance imaging (MRI) of the left hip subsequently confirmed an expansile T1-weighted hypointense and predominantly T2-weighted hyperintense structure with post-contrast rim enhancement in the proximal metadiaphyseal region of the left femur measuring 9.6 x 3.2 x 3.0cm with an associated fracture in the subtrochanteric region (Fig. 1c, d and e).

5

5 Therapeutic intervention

The patient underwent left proximal femur trapdoor osteotomy, curettage, local adjuvant, bone substitute and plating.

The surgery was done under general anesthesia and the patient was positioned supine. A lateral approach was used, elevating the vastus lateralis and keeping the intermedius intact. An anterior bone window fashioned as a trapdoor was created with the intermedius attached using a Midas Rex® Legend® burr B1.

Intraoperative findings include haemoserous fluid upon entering the cystic cavity and visualization of the left proximal femur pathological fracture. Biopsy specimen sent for histopathological examination showed findings compatible with an SBC with a background of fracture site reaction. Extensive curettage of the lesion was done, followed by the application of dehydrated alcohol (95 % ethanol, 5 % water) intralesionally. Following this, internal fixation of the femur was done using a pediatric hip plate (140mm 130°) and 12 screws, and Hydroset® bone cement.

The wound was closed in layers, dressed, and a hip spica was applied.

6

6 Follow-up and outcomes

Postoperative Xrays showed good alignment with implants in situ (Fig. 2a and b). There were no complications and the patient recovered well. Plates and screws were surgically removed 3 years later. The patient was followed up frequently, with the latest follow-up in the clinic being 5 years following the initial surgery. X-ray on arrival at the latest follow-up showed good ossification with no fracture seen (Fig. 5c and d). There were no post traumatic deformities. Patient currently has normal gait and clinically measurements from ASIS to medial malleolus for both legs are equal.

Post-operative plain radiographs of the left proximal femur showing the anterior trapdoor, Hydroset bone cement and paediatric hip plate in the a) anteroposterior view, and b) lateral view.
Fig. 2 Post-operative plain radiographs of the left proximal femur showing the anterior trapdoor, Hydroset bone cement and paediatric hip plate in the a) anteroposterior view, and b) lateral view.
7

7 Discussion

The patient in this case report presented with left knee pain despite the pathology being in the hip. Other than primary knee pathologies, knee pain may be a result of pain referred from the hip via the anterior branch of the obturator nerve, or articular branches of the femoral, common peroneal, or saphenous nerves.6 In a study of cases of hip pathologies regardless of demographic, it was reported that 2–29 % of hip pathology cases have knee pain at presentation.7 Hence, it is prudent that every knee examination be completed with an isolated screening examination of the hip, especially in children where an accurate history may be difficult to obtain. Signs that knee pain may be referred hip pain may include limited ROM exclusive to the hip, such as in this case.

As for treatment intervention, we fashioned a bone window as a trapdoor that preserves attachment of the muscle and periosteum as from experience, this allows quicker healing of the window compared to creating a bone window.8 This can be seen from the callous formation at the fracture site at 6 weeks after surgery (Fig. 3).

Plain radiographs of the left hip at 6 weeks post-operation showing healing callus at the trapdoor site in the a) anteroposterior view and the b) lateral view.
Fig. 3 Plain radiographs of the left hip at 6 weeks post-operation showing healing callus at the trapdoor site in the a) anteroposterior view and the b) lateral view.

As for the cyst itself, curettage was done supplemented with dehydrated alcohol as a local adjuvant. Local adjuvants were used as without histology results, it was difficult to determine intraoperatively if the cystic lesion was an SBC or an aneurysmal bone cyst. Aneurysmal bone cysts are most commonly found in the proximal humerus and femur in children,8 and due to the vague intraoperative findings, it was difficult to make this distinction. With this differential in mind, adding on local chemical adjuvants allows greater margins to be achieved beyond mechanical curettage alone8 by eliminating any possible remaining neoplastic cells and therefore reducing rates of local recurrence.9

Among the local adjuvants available, dehydrated alcohol was chosen because it is less toxic at high concentrations and causes minimal unwanted local tissue damage. It causes necrosis to neoplastic tissue by causing cellular protein denaturation, cellular cytoplasm degeneration, and thromboembolism of small vascularization supplying the tumor.9 Another alternative considered was cryoablation – however, as cryoablation can be dangerous without a vessel to contain it as it may cause thermal burns to surrounding tissue and functional loss, it may do more harm than benefit in this case of a complete fracture.8

With adequate treatment of the primary lesion, bone cementing was done to support the bony defect caused by the cyst. Hydroset® bone cement was chosen as the substituteas it is osteo-inductive and the exothermic reaction caused by cement produces temperatures up to 70 °C-75 °C that is often enough to kill residues of neoplastic cells after curettage.10 It also provides structural support and resorption is slow, allowing healing of the bone before cement resorption. However, in retrospect, cement was not necessary as now surgeons can use cancellous bone chips and when structural support is needed, an allograft fibula strut graft.

In terms of fixation of the fracture itself, as this is a high stress area and there is risk of further collapse of the fracture, plate and screws were deemed optimal for this case. Elastic stable intramedullary nailing (ESIN) and carbon plating were considered but would not have been able to support the fracture sufficiently. However, with the stability that plates and screws offers, this comes at the price of the structure being too rigid and suffering from stress shielding. Stress shielding occurs as a result of a stiffness mismatch between the fracture fixation plates and the bone. While there is need for the fixation to bear some load to stabilize the healing bone fracture, the more rigid and stiff the fixation structure is, the more uneven the load distribution is at the bone-plate interface.11 This difference in Young’s modulus between the plate and bone and stress difference on the bone versus the plate alters the vascularity of the bone beneath the plate, causing bone resorption and reduction in strength in the long term as established by Wolff’s Law. Studies have exemplified this stress shielding relationship where the use of less flexible fixations result in weaker compressive stresses induced at fracture sites which slows healing, and vice versa.12

In addition to affecting fracture healing, this case report also discusses how stress shielding can affect post-fixation surveillance and management of pathological fractures secondary to bone cysts. When the bone cyst occurs in weight-bearing areas such as the femur, the pathological fracture that occurs is usually unstable and requires internal fixation.13 However, when internal fixation is done and the bone is overly shielded from stress, radiographic features of stress shielding (increased cortical thinning and increased radiolucency of bones14), can masquerade itself to look like a cyst recurrence, or vice versa (Fig. 4). This is because SBCs also appear similarly as isolated, unilocular, well-defined radiolucencies with well-defined margins and a characteristic scalloped appearance on radiographs (Fig. 1).15 With the natural history of bone cysts being that 12–45 % recur after curettage and bone grafting,16 surveillance of recurrence post-treatment is hence important to prevent repeat pathological fractures. However, having too many plates and screws obscuring the affected bone can limit the use of advanced imaging such as computer tomographic (CT) scans, and surveillance via 2D radiograph will be subjected to the aforementioned issues.

Plain radiographs of the left proximal femur with plates and screws in situ showing resorption of the bone cement with increased medullary lucency and thinning of the cortex in the a) anteroposterior view and the b) lateral view.
Fig. 4 Plain radiographs of the left proximal femur with plates and screws in situ showing resorption of the bone cement with increased medullary lucency and thinning of the cortex in the a) anteroposterior view and the b) lateral view.
Plain radiographs of the left proximal femur showing an area of lucency and thinning of the cortex post-removal of implants with increased medullary sclerosis and thickening of the cortex one year later in the a) anteroposterior view and b) lateral view, and one year later in the c) anteroposterior view and d) lateral view.
Fig. 5 Plain radiographs of the left proximal femur showing an area of lucency and thinning of the cortex post-removal of implants with increased medullary sclerosis and thickening of the cortex one year later in the a) anteroposterior view and b) lateral view, and one year later in the c) anteroposterior view and d) lateral view.

This is significant as it will determine whether the patient requires repeat curettage if not complete surgical resection of the cyst, or if there is poor remodeling due to the effects of stress shielding. Hence, being able to distinguish a bony cyst from an osteopenic, poorly remodeled bone will affect post-fixation management.

Nonetheless, a consideration would be to simply wait and monitor until fixation removal to assess for cyst recurrence intraoperatively, which was the decision made. Although, there is currently limited literature offering a recommended duration for implants in such cases to be left in place – as while removing the implant to allow for earlier physiological loading of the bone can allow remodeling to happen faster, on the other hand, if there is a recurrence of bone cyst, reopening the area may cause weakening.

To mitigate this, being conservative in the usage of screws and plates can not only reduce the stress shielding phenomenon and therefore promote bone remodeling but also allow for more meaningful post-fixation imaging and surveillance. In this case report, 12 screws were used, which would have reduced the quality of any CT scan performed. However, this could have been circumvented by performing bridge plating, where the plate acts as an extramedullary splint and the zone lesion itself is left unfixed,17 reducing the amount of obscuration from the screws and also avoiding direct concealment of the cyst/fracture zone. This also diminishes the stress shielding effect as the structure is less rigid. For these two reasons, our institution avoids filling up all the plate holes for such cases.

In conclusion, this case report describes the challenges met in managing a case of pathological fracture from a simple bone cyst. It reviews current literature and experiences from our institution to improve the management of such patients. Observing a conservative usage of screws and plates and the optimal location of implants, while still ensuring the stability of the fracture, can allow for easier post-operative surveillance of cyst recurrence through CT scan and swifter fracture healing by reducing the effect of stress shielding on bone remodeling, hence allowing for better outcomes.

Informed consent

We have obtained written permission from parents. All data has been deidentified.

Ethical statement

We declare that this has not been published nor presented elsewhere. We have obtained written permission from parents. All data has been deidentified.

Financial support and sponsorship

The authors declare that no funds, grants, or other support were received during the preparation of this manuscript. The authors have no relavant financial or non-financial interests to disclose.

CRediT authorship contribution statement

Erel Kane Tan Yun En: Manuscript writing, Writing – review & editing. Arjandas Mahadev: Proofing of final manuscript. Mohammad Bin Zainuddin Ashik: Proofing of final manuscript. Kenneth Pak Leung Wong: Data collection, Writing – review & editing, Proofing of final manuscript.

References

  1. , , , , , , . Interventions for treating simple bone cysts in the long bones of children. Cochrane Database Syst Rev. 2017;2017
    [Google Scholar]
  2. , , , , , , . Interventions for treating simple bone cysts in the long bones of children. Cochrane Database Syst Rev. 2017;2017
    [Google Scholar]
  3. , , . A method of quantification of stress shielding in the proximal femur using hierarchical computational modeling. Comput Methods Biomech Biomed Eng. 2006;9:35-44.
    [Google Scholar]
  4. , , . Growth plate mechanics and mechanobiology. A survey of present understanding. J Biomech. 2009;42:1793-1803.
    [Google Scholar]
  5. , , , . Host response to biomaterials for pelvic floor reconstruction. Host response to biomaterials: the impact of host response on biomaterial selection. 2015
    [Google Scholar]
  6. , , , , , . Knee joint pain may Be an indicator for a hip joint problem in children: a case report. Malays J Med Sci. 2011;18:79.
    [Google Scholar]
  7. , , , , . Don't forget the hip! Hip arthritis masquerading as knee pain. Arthroplast Today. 2018;4:118.
    [Google Scholar]
  8. , , . Rare right acetabulum aneurysmal bone cyst treated with curettage and local adjuvants in a 4-year-old girl. BMJ Case Rep. 2021;14
    [Google Scholar]
  9. , , , et al . Local adjuvants in surgical management of bone lesions. J Cancer Ther. 2015;6:473-481.
    [Google Scholar]
  10. , , , . Calcium phosphate bone cements as local drug delivery systems for bone cancer treatment. Biomater Adv. 2023;148
    [Google Scholar]
  11. , , , , , . Stress analysis in a bone fracture fixed with topology-optimised plates. Biomech Model Mechanobiol. 2020;19:693.
    [Google Scholar]
  12. , , , . Biomechanics of bone-fracture fixation by stiffness-graded plates in comparison with stainless-steel plates. Biomed Eng Online. 2005;4:46.
    [Google Scholar]
  13. , , . Pathological fracture of distal humerus due to a simple bone cyst managed with fibula grafting and osteosynthesis. J Orthop Case Rep. 2019;9:49.
    [Google Scholar]
  14. Osteoporosis imaging: practice essentials, radiography, computed tomography n.d.
    [Google Scholar]
  15. , , , et al . Simple bone cyst: description of 60 cases seen at a Brazilian School of Dentistry and review of international literature. Med Oral Patol Oral Cir Bucal. 2020;25:e616.
    [Google Scholar]
  16. , , , et al . Treatment outcomes of the simple bone cyst: a comparative study of 2 surgical techniques using artificial bone substitutes. Medicine. 2018;97
    [Google Scholar]
  17. Orif - bridge plating for Segmental, fragmentary, middle 1/3 fractures n.d.
    [Google Scholar]
Show Sections