Successful treatment of recurrent knee hemarthrosis after total knee arthroplasty using Bactisure wound lavage during synovectomy: A novel intervention

Author affiliations
St. George's University School of Medicine, Grenada
Article History
Article tools · PDF & citations

Abstract

Abstract

Recurrent hemarthrosis of the knee is a rare and challenging condition, often resistant to conventional treatments. We present the case of a 60-year-old caucasian male with persistent knee hemarthrosis, unresponsive to hematologic evaluation, conservative therapy, and genicular artery embolization (GAE) status post-total knee arthroplasty. Due to ongoing symptoms, the patient underwent open synovectomy with exchange of the polyethylene insert and adjunctive use of Bactisure wound lavage, leading to complete resolution of bleeding. The use of Bactisure wound lavage in this case was primarily for its role in decreasing the chance of infection as well as for the surfactants' hypothesized role in hemostasis. This report highlights the first documented use of Bactisure lavage during synovectomy, suggesting a novel, effective approach for managing refractory hemarthrosis in patients after undergoing total knee arthroplasty.

Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Recurrent hemarthrosis of the knee is a rare and often debilitating condition. While bleeding disorders, trauma, and vascular abnormalities are common causes, some cases remain idiopathic, making treatment difficult. Recurrent hemarthrosis is considered a rare complication of total knee arthroplasty as referenced relevant studies show that only 0.3 % of patients experience this complication and on average, the bleeding occurs more than 2 years after undergoing total knee arthroplasty1. If initial measures such as conservative care or embolization fail, surgical options, including synovectomy, may be pursued to prevent further bleeding (Table 1).

Table Comparison of treatment options for recurrent knee hemarthrosis.
Treatment Modality Mechanism of Action Advantages Disadvantages/Complications
Conservative Management (Rest, NSAIDs, Aspiration) Reduces inflammation and relieves acute symptoms Minimally invasive, first-line treatment Often ineffective for persistent cases
Genicular Artery Embolization (GAE) Blocks blood supply to inflamed synovium Minimally invasive, high success rates Risks: pain, tissue necrosis, incomplete resolution
Synovectomy (Arthroscopic/Open) Removes hypertrophic synovium causing bleeding Definitive treatment for refractory cases Invasive; requires recovery and rehabilitation
Bactisure Wound Lavage (as adjunct) Chemical debridement of tissues and surfactant effect Potential hemostatic effect, antimicrobial properties Experimental; not yet established for this indication

This report describes a case in which synovectomy, performed with Bactisure wound lavage, led to the resolution of hemarthrosis in a patient with persistent knee bleeding after having undergone total knee arthroplasty. The unexpected therapeutic effect of the wound lavage suggests a novel application for this product in orthopedic surgery. The lower recurrence and faster recovery of the hemarthrosis in this case compared to other cases that underwent open synovectomy alone, suggest that Bactisure wound lavage played an important adjunctive role in the case of this patient.

2

2 Case presentation

Patient history: A 60-year-old overweight male status post-total knee arthroplasty presented with recurrent episodes of spontaneous hemarthrosis of the left knee, each accompanied by severe swelling, discomfort, and restricted mobility. Over the course of 6 months, the patient experienced multiple episodes requiring joint aspiration for symptomatic relief.

Workup and initial management: The patient was referred to a hematologist to rule out a bleeding disorder. Laboratory tests, including complete blood count, prothrombin time, activated partial thromboplastin time, von Willebrand factor levels, and platelet function tests, were all within normal limits. The patient also takes Eliquis for another unrelated condition which was stopped although this was not necessarily suspected as the main cause due to the unilateral nature of the hemarthrosis. A hematologic cause for the recurrent bleeding was excluded.

Intervention 1 – Genicular artery embolization: Given the failure of conservative management and the negative hematologic workup, the patient was referred for genicular artery embolization to reduce vascular supply to the knee.2,3 However, this intervention did not resolve the hemarthrosis and led to complications, including post-embolization pain, localized tissue ulceration, and peripheral neuropathy of the peroneal nerve.

Decision for synovectomy: With persistent symptoms and failed embolization, the orthopedic team elected to perform an open synovectomy. The goal was to remove the inflamed synovial tissue, which was presumed to be the source of bleeding. During the procedure, Bactisure wound lavage (Zimmer Biomet) was used as part of the washout process. The team hypothesized that the surfactants in Bactisure might act as a chemical peel on the synovial membrane, further promoting hemostasis and preventing future bleeding.

Outcome: Following the synovectomy with Bactisure lavage, the patient had no recurrence of hemarthrosis. Over a follow-up period of 1 year, the patient reported complete resolution of symptoms, with no further joint swelling or bleeding. The knee regained full range of motion, and there were no adverse effects from the procedure.

3

3 Discussion

Recurrent hemarthrosis, particularly when not associated with acute trauma or underlying bleeding disorders, can arise from several potential mechanisms. One theory is synovial hypertrophy, where excessive growth of the synovial lining leads to fragile, abnormal blood vessels prone to micro-rupture. Inflammatory processes within the joint may also impair normal coagulation, increasing the likelihood of spontaneous bleeding. Additionally, minor joint instability or overuse, especially after total knee arthroplasty could contribute to repeated micro-injuries, triggering recurrent bleeding episodes. Recurrent hemarthrosis is considered a rare complication of total knee arthroplasty as this was experienced by only 0.3 % of patients in referenced relevant studies with a sample size of 5510 patients.1 This creates a vicious cycle: bleeding induces further synovial inflammation, which exacerbates vascular fragility, perpetuating hemarthrosis.

In this case, the synovectomy aimed to halt this cycle by physically removing the inflamed synovium. The use of Bactisure wound lavage is postulated to have augmented the effect by acting as a surfactant, chemically debriding the synovial lining and stabilizing the local microvasculature. This novel mechanism suggests that adjunct chemical agents may provide therapeutic benefits beyond traditional surgical approaches.

Recurrent hemarthrosis presents a significant therapeutic challenge, particularly when no underlying cause is identified and conventional interventions fail. Surgical synovectomy is often used in refractory cases to remove inflamed synovium and prevent further bleeding. However, this case is unique in that the addition of Bactisure wound lavage seemed to enhance the outcome.

Bactisure wound lavage as a novel intervention: Bactisure is typically employed for its antimicrobial properties in the treatment of infected wounds.4,5 However, its composition—surfactants that disrupt biofilm—may also act on the synovium in a manner similar to a chemical peel, promoting tissue remodeling and hemostasis. This novel use of Bactisure in an orthopedic setting has never been described before in the relevant medical literature.

Comparison with genicular artery embolization: GAE has gained popularity as a minimally invasive approach to managing recurrent hemarthrosis, with favorable results in many cases. However, complications such as post-procedural pain, soft tissue necrosis, and incomplete hemostasis can occur. In this case, GAE was ineffective and led to additional complications, underscoring the need for alternative interventions.

Limitations and future research: While this case highlights a promising outcome, it is a single observation. Additional cases or controlled studies are needed to determine whether the use of Bactisure wound lavage during synovectomy can be broadly applied as a treatment for recurrent hemarthrosis.

4

4 Conclusion

This case report describes the successful resolution of recurrent knee hemarthrosis following synovectomy with the use of Bactisure wound lavage. The observed effectiveness of this combination suggests that Bactisure may offer additional therapeutic benefits beyond its antimicrobial properties, potentially due to its hemostatic effects attributed to the presence of components such as acetic acid in the solution. To our knowledge, this is the first reported case of its kind. Future research may explore the potential role of chemical adjuncts such as Bactisure in promoting hemostasis during orthopedic procedures.

Data availability statement

The data supporting the findings of this study are available upon reasonable request from the corresponding author. Due to privacy and ethical restrictions, some data may not be publicly accessible.

Ethics statement

This study was conducted in accordance with the ethical standards of the Declaration of Helsinki.

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Show Sections