Tethered drain after total knee replacement - Two different case scenarios and review of literature

Author affiliations
Rathimed Speciality Hospital, Q/102,3rd Ave,Block Q, Anna Nagar, Chennai, Tamil Nadu, 600040, India
Article History
Corresponding author(s)

∗Corresponding author: N. Ragunanthan. ragunanthan@rediffmail.com

Article tools · PDF & citations

Abstract

Abstract

Suction drain after total knee arthroplasty, even though constantly debated, is commonly used for its advantages of reducing haematoma, postoperative and swelling. Drain tethering, although less commonly reported if happens, increase the stress for both patient and surgeon, may warrant second surgery and increase the risk of infection.

We report two case scenarios of tethered drain after total knee replacement. The first patient was a 58-year-old female in whom the drain was caught by the fascial sutures, while in the second patient who was a 63-year-old female in whom the drain was caught between the joints and crushed. The former was managed with a re-surgery, while the drain in the latter case was successfully removed with reattempt with knee flexion.

Although underreported, the drain tethering after total knee replacement is a completely preventable complication and can affect recovery, increase anxiety, often leading to second surgery. Differentiating and identifying the cause of tethering can avoid unwarranted surgery and as well as properly plan for the drain retrieval.

Keywords

  • Arthroplasty
  • Complication
  • Drain
  • Tethered
  • Sutured
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The usage of surgical drains after total knee replacement, though controversial, is still a commonly followed practice for its advantages of preventing haematoma formation and reducing postoperative swelling and pain.1 Albeit rare, tethered drain after a total knee replacement, if happened, can be stressful to the patient as well as the surgeon. A tethered drain increase the chance of infection, possibility of second surgery, and higher financial expense.2 The most common cause of tethering is unintended suture fixation during wound closure, the other reasons include folding, local compression, soft tissue incarceration, etc.3

We here are reporting two different scenarios of tethered drain we encountered after total knee replacement surgeries, as well as review of the literature about tethered drains.

2

2 Case 1

2.1

2.1 Background

A 58 year old female with grade 3 medial compartment osteoarthritis, right knee without any comorbidities, has undergone uneventful cruciate sacrificing total knee replacement under spinal anaesthesia (Fig. 1). A closed suction drain (Romovac suction drain, No. 12, Romsons International, Noida, India, Ltd) was placed intra-articular towards the lateral gutter under direct visualization before wound closure.

Postoperative anteroposterior and lateral radiographs showing drain in lateral gutter with proximal part deviating towards midline.
Fig. 1 Postoperative anteroposterior and lateral radiographs showing drain in lateral gutter with proximal part deviating towards midline.
2.2

2.2 Findings

Post-operative radiographic evaluation confirmed satisfactory position of both femoral and tibial components, with the distal part of the surgical drain occupying the lateral gutter and proximal part turning towards midline. As per the standard hospital protocol, drain removal was attempted after 24 hrs on the first post-operative day. The registrar tried to pull the drain out, but was unable to do so even with moderate force. It was noted that the drain was tethered and on applying excessive force the patient had severe pain at the wound site. The drain was presumed to be caught on the sutures, and the situation was explained to the patient. It was decided not to repeat pulling with excess force in order to avoid the potential complication of drain breakage.

2.3

2.3 Therapeutic intervention

With patient's consent, the decision was taken to remove the drain in operation theatre under sterile precaution with short general anaesthesia. On the second post-operative day under short general anaesthesia, after sterile draping, the sutures were removed from the skin from proximal end up to the midway to expose the fascial layer sutures. The drain was the pulled to visualize any movement in the fascial layer. The movements were noted in the proximal part of the fascial closure. The sutures were sequentially released one by one while pulling the drain intermittently. On removal of the third suture at the proximal part, the drain came out with ease. The suture bite on the drain was visualized and the entirety of the drain is confirmed under direct visual examination as well post-operative knee radiographic evaluation (Fig. 2). Wound Wash was given and closed in layers. The remaining post-operative period was uneventful. On 3 month follow-up, the patient had no complaints with range of motion of 0–120 degrees.

Image showing suture bite on the drain after removal.
Fig. 2 Image showing suture bite on the drain after removal.
3

3 Case 2

3.1

3.1 Background

A 63 year old female patient with bilateral grade 4 Osteoarthritis was admitted for bilateral total knee replacement. As per hospital protocol, the most affected knee will be replaced first, followed by second knee surgery done on the fourth post-operative day. She underwent cruciate retaining kinematic total knee replacement for her left knee first under spinal anaesthesia with closed suction drain (Romovac suction drain, No. 12, Romsons International, Noida, India, Ltd) placed intra-articular along the lateral gutter (Fig. 3).

Post operative anteroposterior and lateral radiograph showing drain towards the midline.
Fig. 3 Post operative anteroposterior and lateral radiograph showing drain towards the midline.
3.2

3.2 Findings

Post-operative radiographs were satisfactory and physiotherapy was started after 12 hours as per hospital protocol. The drain removal as planned was attempted after 24 hours by the registrar. It was noted that the drain was tethered and was not coming, even on considerable force. The drain removal was again attempted by the operating surgeon and failed. It was noted that with both the attempts, even with considerable force, the patient didn't have any exaggeration of pain.

3.3

3.3 Therapeutic intervention

Even though it was presumed to be caught on the sutures, the absence of pain exaggeration created doubt to suspect other possibilities. Considering the possibility of the drain tip getting jammed between the knee components, the decision to attempt drain removal with knee flexion and extension was taken and the same was attempted. The drain came out easily once the knee was flexed to 50 degrees. On visual evaluation, the drain tip was noted to be crushed by getting jammed between the joints (Fig. 4). The entirety of the drain is confirmed under direct visual examination and knee radiographs. The patient had an uneventful course and proceeded with right knee replacement as planned. At 3 months follow-up, the patient had no pain and a range of movement of 0–120 degrees.

Image showing crushed distal part of the drain after removal.
Fig. 4 Image showing crushed distal part of the drain after removal.
4

4 Discussion

The use of suction drain after total knee arthroplasty is constantly debated. The fear of infection following haematoma formation is the common reason for a drain usage, even though various studies have showed some amount of haematoma is always left uncleared.4 Recent meta-analysis on drain usage showed increased incidence of infection in the non-drained group, even though not statistically significant.5 Ecchymosis and persistent discharge from the wound has been found statistically significant in multiple studies in literature.6,7 But concerns associated with drain usage include irritating pain, increased blood loss, risk of retrograde infection, risk of getting sutured or entrapped within the wound and drain breakage.4

The most common cause for a tethered drain is accidental suturing during the wound closure, and other reasons being the incarceration of soft tissue, folding, local compression, etc.2 Preventing the suture entrapment as well as identifying the same intraoperatively is the best way to avoid this devastating complication. Different techniques to avoid this has been documented in the literature. First technique involve exiting the drain laterally and keeping the drain mark well inside the skin level and tucking the drain into the lateral gutter away from the suturing.8 Once suturing is finished, pull the drain out until the marker is at the skin level. Free and smooth gliding will indicate no tethering of the drain. Another technique advises once the drain is inserted, the free end is pulled out through the distal end of the wound.9 Once the fascial closure reaches the distal end, the drain is pulled into the joint under the protruding end slides under the closed layer. Tethering is indicated by the presence of resistance while pulling the drain. Similarly, one can also place a haemostat at the free end of the drain and once the fascia is closed proximally, to and fro sliding motion of the drain tube is done to evaluate tethering before final closure at the distal end.10 In our hospital, we follow the first technique of placing the drain into the lateral gutter and pulling the drain to check free motion after the fascial closure.

Drain retention beyond 48h is not advised, as it increases the risk of retrograde infection. In our hospital, we routinely remove the drain after 24hrs.11 Different techniques have been documented in the literature regarding removal of entrapped drains. These techniques should be tried at the discretion of the surgeon and patient's tolerance, as excess force on a tethered drain can result in breakage and intra-articular retention. One technique was described by Redman et al. where they apply gentle traction with one haemostat and a second haemostat is pushed along the drain as much as possible and clamped.12 Gentle traction is now applied with the second haemostat, and the first haemostat is removed and clamped again as far as possible. This is repeated until the suture tethering is encountered, on which the suture can be cut and drain is removed. The two pitfalls associated with this is that the pain associated with traction make it difficult to do without anaesthesia, as well as risk of drain breakage. The authors also noted that if the depth of the suture is more than 7 cm, the technique is less likely to work.

Hess et al. described a technique where they threaded the drain through a tendon stripper and advanced along its path until the resistance of tethered suture is encountered on which gentle push and rotation of the stripper clockwise and counter clockwise is done to cut through the suture, and free the drain.13 Another technique involves inserting a sharp Steinmann pin of appropriate size to cut the suture within the drain lumen, protecting the tissues.14 Silicon drains which are softer than PVC (Polyvinyl Chloride) drains are found to be removable with gentle traction and twisting the drain five to seven times.15 Recently Hui et al. used ultrasound to locate drain tethering where they described sliding sign.16 On repeatedly pulling and relaxing the drain, the proximal segment will be motionless compared to the distal segment resulting in disappearance of sliding sign and corresponds to the point of tethering.

There were a couple of case reports in the past where drain gets caught between the knee joint components and removal of drain was achieved through knee flexion and extension.17,18 In this case report, we are presenting two different case scenarios where in one case the drain was caught on fascial sutures while in the other where the drain was crushed between the joint components. It is important to differentiate these two situations as one may need second surgery for removal while in the second scenario gentle traction with knee flexion extension movements will facilitate drain removal and avoid a second surgery. We noted that the case in which the drain was tethered on sutures, even on a minimal increase in pulling force, results in severe pain on the patient's wound as it is similar to indirectly pulling the patient's fresh wound. This is important as even with considerable force, no such pain was elicited in the second case, which will help us to differentiate between two case scenarios. In the second case we don't know the exact cause for drain to get caught between the joints, but we believe it to be due to the early physiotherapy we start as per our hospital protocol.

Also in the first case, the drain removal technique we followed is minimally damaging, as only the part of superficial wound where the drain is close to the midline on X-ray was opened. The point of tethering was identified by movement of the fascial layer on pulling the drain and subsequent cutting of suture in this region allowed for easy drain removal, avoiding extensive suture removal. Post removal, the drain tube should always be inspected for the entirety. A method is described by Jaffer et al. where in all the drains are cut between sixth and seventh drain holes in such a way as to leave 6 full holes inside the joint.8 This will add to the assurance of entirety of drain once removed.

Tethered drains after a total knee replacement and subsequent drain retention are likely to be underreported because of the concern of legal implications. Although proper precautions can reduce the risk of this complication, cases still do occur and proper identification of cause of tethering may avoid a second surgery and gave peace of mind to the operating surgeon and the patient. Learning points from this case series is summarised in Table 1.

Learning Points
1. Follow techniques to avoid drain entrapment meticulously
2. Always check for suture entrapment of drain before skin closure
3. Remove the drain before 48 hrs as it avoids retrograde infection
4. Not all drain tethering's are due to suture entrapment
5. Drain tethering between joints may be released with joint movements
5

5 Conclusion

Although underreported, the drain tethering after total knee replacement is a completely preventable complication and should not occur. They can affect recovery and increase anxiety, often leading to second surgery. Following proper preventive techniques and extra vigilance intraoperatively can avoid this complication. Differentiation of the cause of tethering from suture entrapment and getting trapped by the knee components will help in avoiding a second surgery.

Declaration of patient consent

An informed consent was taken from the patient.

Financial support and sponsorship

None.

References

  1. , , , , , , . Role of suction drain after knee arthroplasty in the tranexamic acid era: a randomized controlled study. Clin Orthop Surg. 2019 Mar;11(1):73-81.
    [Google Scholar]
  2. , , , et al . Optimal management of tethered surgical drains: a cadaver study. J Am Acad Orthop Surg. 2019 Feb 15;27(4):129-135.
    [Google Scholar]
  3. , . Retained broken wound drains: a preventable complication. JOrthop Trauma. 2000;14:212-213.
    [Google Scholar]
  4. , , , . The use of closed suction drain in total knee arthroplasty. A prospective, randomized study. J Bone Joint Surg Br. 2003;85:215.
    [Google Scholar]
  5. , , , . Use of closed suction drain after primary total knee arthroplasty - an overrated practice. SICOT J. 2016;2:39.
    [Google Scholar]
  6. , , , , , , . Comparison between closed suction drainage and nondrainage in total knee arthroplasty a meta-analysis. J Arthroplasty. 2011;26(8):1265-1272.
    [Google Scholar]
  7. , , , et al . Comparison of closed suction drainage and no drainage after primary total knee arthroplasty. Orthopedics. 1997;20:1121-1124.
    [Google Scholar]
  8. , , , . Drain technique in elective total joint arthroplasty. Orthopedics. 2014;37(1):37-39.
    [Google Scholar]
  9. , , , . Retained surgical drain after total knee arthroplasty: an eight-year follow-up: a case report. JBJS Case Connect. 2015 Jul-Sep;5(3):e63.
    [Google Scholar]
  10. , , , . Technique for removing entrapped penrose drains. Urology. 1975;6:371.
    [Google Scholar]
  11. , , , , . Minimally invasive surgical technique for tethered surgical drains. Indian J Orthop. 2017;51:213-216.
    [Google Scholar]
  12. , , , . Removal of surgically entangled drain: a new original nonoperative technique. Int J Curr Med Sci Pract. 2003;10:63-64.
    [Google Scholar]
  13. , , . Technique for removal of snared silicone drains. Orthopedics. 2000;23:543-545.
    [Google Scholar]
  14. , , , et al . The use of ultrasound to locate a tethered surgical drain: a novel way to achieve fast removal. BMC Surg. 2020;20:264.
    [Google Scholar]
  15. , , , , . Entrapment of closed suction drain after robotic-assisted total knee arthroplasty: a rare entity. Sur Cas Stud Op Acc J. 2020;5(3)
    [Google Scholar]
  16. , . Suction drainage tube entrapment in total knee arthroplasty. Clin Orthop Relat Res. October 1990;259:157-159.
    [Google Scholar]
Show Sections