Triple disruption of superior shoulder suspensory complex of shoulder combined with clavicular shaft fracture: A case report and review of literature
Article History
-
Received: ,
Accepted: ,
Abstract
Abstract
Triple disruption of the superior shoulder suspensory complex (SSSC) is a rare injury which affects 3 or more structures of this ring. This paper aims to report the patient who suffered from this challenging injury and a review of literatures which had similar disruption.
A 51-year-old male who sustained right shoulder injuries, which consisted of mid-shaft clavicular fracture, acromion fracture, scapular body fracture, acromioclavicular joint and coracoclavicular joint disruption after a motorcycle accident. He was treated with clavicle and acromion fracture fixation combined with coracoclavicular joint and acromioclavicular joint stabilization.
Triple or quadruple disruption of the SSSC ring is an extremely rare injury that is caused by high-energy trauma. This injury is often associated with other injuries and aggressive care should be taken for this group of patients. Good preoperative planning and proper surgical fixations are crucial for a satisfactory outcome of shoulder joint function.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
The concept of superior shoulder suspensory complex (SSSC) was defined by Goss1 since 1993. The SSSC are bony and soft tissue structures which form a ring around the shoulder girdle. They are composed of glenoid fossa, coracoclavicular (CC) ligament, coracoacromial (CA) ligament, distal clavicle, acromioclavicular (AC) joint, and acromion. The SSSC ring is connected superiorly to the middle third of the clavicle and connected laterally with the scapular body and scapular spine. This ring is important for shoulder functions as it provides a point for multiple soft tissue attachment, maintains a stable connection between the upper extremity and the axial skeletal system, and serves for shoulder joint biomechanics. Ganz and Noesberger2 defined a combined ipsilateral mid-shaft clavicle and scapular neck fracture as a “floating shoulder injury,” which causes the upper extremity to disengage from the axial skeleton. Several studies defined disruption to at least 2 points structures of this SSSC ring as floating shoulder and indicated for surgical stabilization.3–8 Though, some studies reported good functional outcomes after nonoperative treatment.9,10 Furthermore, triple or quadruple SSSC ring disruption causes extremely unstable shoulder girdle and the need for surgical treatment to restore the upper extremity function.11–20
We reported an extremely rare injury to the SSSC ring. This case was a patient who sustained the triple disruption of SSSC ring; AC ligament disruption, CC ligament disruption and acromion fracture. Additionally, our patient also got a mid-clavicular shaft fracture and a scapular body fracture which disconnected the SSSC from the axial skeleton. The operation was planned for fixation of the clavicle with 3.5-mm reconstruction locking compression plate, coracoclavicular stabilization with suture loop over Endobutton and screw fixation of the acromion process. The fracture healed uneventfully after surgical fixation. These complex fractures and ligament disruptions are a rare situation which need meticulous and well-planned surgical treatment.
2 Case
A 51-year-old man sustained right shoulder pain from a traffic accident. The clinical examination showed marked swelling and extensive ecchymosis around the right shoulder without any open wound. The shoulder range of motion was limited by pain. There is no weakness of elbow, wrist and fingers motion. The sensation and distal pulse were intact. Plain radiographs of the right shoulder demonstrated fracture of the mid-clavicular shaft, fracture of the scapular spine, 2nd-7th rib fractures and disruption of the AC and CC intervals (Fig. 1a). Further three-dimensional CT scans revealed a minimally displaced acromion process fracture (AO/OTA 14A2), scapular body fracture (AO/OTA 14B2∗), dislocation of the AC joint with widening of CC distance and oblique midshaft clavicular fracture (AO/OTA 15.2A) (Fig. 1b, c and 1d). The coracoid was intact. Surgical treatment was considered according to triple disruption of SSSC (acromion fracture, disruption of AC and CC ligaments) (Fig. 2). After discussed with the patient, surgical fixation was done on 7 days after the injury.


The preoperative planning was prepared for bony stabilization first. Then, soft tissue and ligament repaired were achieved after skeletal stabilization. A 3.5-mm locking reconstruction plate fixation of mid-clavicular shaft fracture, screw fixation of acromion process, CC stabilization with suture loop and AC joint stabilization were planned, respectively.
The preoperative antibiotic, 1st generation cephalosporin, was administered. Under general anesthesia, with the patient in beach chair position, two saber incisions were performed over the mid-clavicular area and the lateral clavicular area. The mid-clavicular shaft fracture was stabilized with a lag screw, and a 3.5 mm. locking reconstruction plate (Synthes) was applied as a neutralization plate through medial and lateral windows (Fig. 3). Screw fixation of acromion fracture was performed with a 3.5 mm cortical screw in an anterior to posterior direction through a lateral surgical window. After clavicular and acromion fracture fixations were done, the anatomical integrity of the AC joint was restored. Then, CC stabilization with 2 loops of No.5 FiberWire suture (Arthrex) loop under the coracoid was performed. FiberWire sutures were secured and tightened over the Endobutton, which lay on the superior surface of the distal clavicle. Finally, AC joint stabilization was done with No.5 Ethibond suture (Ethicon) in a figure of eight fashion and the torn AC joint capsule was repaired (Fig. 4). The intraoperative fluoroscope was checked. Hemostasis was achieved. The subcutaneous and skin were closed, respectively. The antibiotic was continued for 24 hours. Postoperative radiographs showed anatomical restoration of the shoulder girdle; anatomical alignment of clavicle and acromion fixation; normal CC distance compared with the contralateral site; and anatomical reduction of the AC joint (Fig. 5). After one week, the patient was permitted to begin passive range-of-motion exercises, and after six weeks, active exercises. He had weakness of the shoulder abduction and was diagnosed as an upper-arm type brachial plexus injury during follow up. Fractures were healed uneventfully, and the patient got satisfactory recovery of the function of the right shoulder at 2-year follow up. (Fig. 6).




3 Discussion
“Floating shoulder” is defined as at least double disruption of SSSC structures. Surgical fixation is indicated for this kind of injury.3–8 Furthermore, triple SSSC disruptions are extremely rare, are associated with high-energy trauma, and result in a severely unstable shoulder girdle. This rare situation is usually associated with other system injuries such as neurological injury, pulmonary contusion, rib fractures, and blunt abdominal injury. Our case demonstrated a 51-year-old male who suffered from a midshaft clavicular fracture, disruptions of AC and CC ligaments, an acromion and scapular body fracture. After surgical fixation of the clavicle, acromion, and CC and AC stabilization, all fractures healed properly and the functional outcome is excellent.
Previous studies have identified triple SSSC disruptions as a very rare injury. Triple or quadruple injury of SSSC has been reported in only six publications in English literature14,15,17,18,19,20 (Table 1). The largest study, published by Mulawka et al.,17 reported 15 patients who got at least triple disruptions of the SSSC ring, 12 patients with triple disruptions, and 3 patients with quadruple disruptions. Eighty-seven percent of patients sustained nerve injuries, and 87% of patients had associated ribs fractures. Displacement of more than 1 cm is indicated for surgery at each injury site. Surgical repair was done at 89% of injury sites (38/48) according to surgical criteria. The functional outcome was satisfactory, with the disabilities of the arm, shoulder and hand (DASH) score of 14.9. The range of motion was 95% forward flexion, 92% abduction, and 78% external rotation compared to the uninjured site. Ogawa et al.14 reported 36 cases of multiple disruptions of SSSC which included 10 patients who had triple disruptions. Although authors did not identify how many fixations were done among triple disruptions cases, operative fixation was performed in 78% (62 of 80) of all lesions in their series.
| Study | Year | N | Structure of injuries | Treatment | |||||
| Clavicle | CC | Coracoid | Glenoid | Acromion | AC | ||||
| Lecoq et al.11 | 2001 | 1 | + | + | + | Operative treatment only coracoid fracture | |||
| Oshima et al.12 | 2002 | 7 | +(4) | + | + | Operative treatment = 6, Nonoperative treatment = 1 | |||
| + | + | + | |||||||
| +(2) | + | + | + | ||||||
| Jung et al.13 | 2011 | 1 | + | + | + | Operative treatment | |||
| Ogawa et al.14 | 2012 | 10 | + | + | Operative treatment | ||||
| +(2) | + | + | |||||||
| +(2) | + | + | |||||||
| Kim et al.15 | 2012 | 1 | + | + | + | Operative treatment | |||
| Mariño et al.16 | 2013 | 1 | + | + | + | Operative treatment | |||
| Mulawka et al.17 | 2015 | 15 | +(3) | + | + | Triple disruption, operative treatment | |||
| +(2) | + | + | |||||||
| +(2) | + | + | |||||||
| +(2) | + | + | |||||||
| +(2) | + | + | |||||||
| + | + | + | |||||||
| + | + | + | + | Quadruple disruption, operative treatment | |||||
| + | + | + | + | ||||||
| + | + | + | + | ||||||
| Badam et al.18 | 2019 | 1 | + | + | + | Operative treatment | |||
| Wu et al.19 | 2020 | 1 | + | + | + | Operative treatment | |||
| Yang et al.20 | 2022 | 1 | + | + | + | + | Operative treatment 3 of 4 lesions | ||
| Our study | 2022 | 1 | + | + | + | + | Operative treatment 4 of 4 lesions | ||
In 2001, Lecoq et al.11 reported the first publication of triple SSSC disruption affecting the coracoid, acromion, and clavicular fracture. Internal fixation of the coracoid was done while the acromion and clavicle were treated conservatively. Oshima et al.12 reported another large series of triple and quadruple disruptions, which were treated with operative treatment in 6 patients and 1 with nonoperative treatment. Most recently, Yang et al.20 published a case report with a quadruple disruption patient who got a coracoid, acromion, and clavicular fracture combined with grade II AC joint separation. Surgical fixation of the acromion, coracoid, and distal clavicle were done without any AC joint stabilization. Even though the immediate post-operative radiograph shows satisfactory reduction, AC joint separation was observed at the fourth week after fixation.
Our study reported a rare injury that affected triple disruptions of SSSC with associated clavicular and scapular body fractures. This kind of injury needs good knowledge of anatomy around the shoulder girdle and good pre-operative planning for a satisfactory outcome after surgical treatment. Even if the clavicular shaft is not one of the SSSC structures and fracture in this area is not determined as SSSC disruption, when a mid-shaft clavicular fracture was present, the superior connection to the SSSC ring was severed from the axial skeleton. Our pre-operative planning was for restoration of all disruptions, which started with bony fixation to achieve skeletal anatomy relationship at the acromioclavicular joint and was followed by ligament reconstruction and stabilization. Some surgeons only repaired two of the three disruptions, but we believed that fixing all disruption points would reduce deforming force on our implants and sutures. This concept could lead to a satisfactory outcome and prevent fixation failure in this injury treatment.
From our case, we conclude the concept of treatment in superior shoulder suspensory complex disruption is as follows.1.Determine injury structures of the SSSC ring, which include the glenoid fossa, CC ligament, CA ligament, distal clavicle, acromioclavicular joint, and acromion process. Two or more injury structures cause a significant compromise of SSSC ring stability.2.Try to repair all the injured structures to reduce the deforming force according to massive instability. Stable fixation could lead to early rehabilitation, which promotes a good functional outcome.3.Begin with bony fixation to reestablish a nearly normal anatomy relationship, then move on to soft tissue reconstruction or joint stabilization.4.Early rehabilitation to avoid shoulder joint stiffness after a severe injury, as well as aggressive surgical treatment.5.The associated neurovascular structure injury must be thoroughly investigated.
4 Summary
Triple or quadruple disruptions of the SSSC ring is an extremely rare injury that is caused by high-energy trauma. This injury is often associated with other injuries, and aggressive care should be taken for this group of patients. Good pre-operative planning and proper surgical fixations are crucial for a satisfactory outcome of shoulder joint function.
Funding
No funds have been received for this study.
Inform consent
Informed consent was obtained for the patient.
Author contributions
CJ and PR were involved in drafting and revising the manuscript for content, including the medical writing for the content and review literatures. PR was drawing the illustrations. SS and PB involved in revising manuscript.
Ethic approval
This study has been approved by the ethical committees of our institute in accordance with the declaration of Helsinki.
References
- Double disruptions of the superior shoulder suspensory complex. J Orthop Trauma. 1993;7(2):99-106.
- [Google Scholar]
- Open reduction and internal fixation of ipsilateral fractures of the scapular neck and clavicle. J Bone Joint Surg Am. Jul. 1993;75(7):1015-1018.
- [Google Scholar]
- The unstable shoulder girdle: early functional treatment utilizing open reduction and internal fixation. J Orthop Trauma. Apr. 1995;9(2):93-97.
- [Google Scholar]
- The floating shoulder: clinical and functional results. J Bone Joint Surg Am. Aug. 2001;83(8):1188-1194.
- [Google Scholar]
- The floating shoulder. A multicentre study. J Bone Joint Surg Br. Aug. 2001;83(6):795-798.
- [Google Scholar]
- Clinical and functional results after floating shoulder injuries. J Trauma. Sep. 2004;57(3):595-602.
- [Google Scholar]
- The floating shoulder: a biomechanical basis for classification and management. J Bone Joint Surg Am. Aug. 2001;83(8):1182-1187.
- [Google Scholar]
- Conservative treatment of ipsilateral fractures of the scapula and clavicle. J Trauma. Feb. 1997;42(2):239-242.
- [Google Scholar]
- Nonoperative treatment of ipsilateral fractures of the scapula and clavicle. J Bone Joint Surg Am. Jun. 2000;82(6):774-780.
- [Google Scholar]
- [Triple fracture of the superior shoulder suspensory complex] Acta Orthop Belg. Feb. 2001;67(1):68-72.
- [Google Scholar]
- Complex injury patterns of the shoulder girdle-three or four-site injury. Shoulder Joint. 2003;27:555-559.
- [Google Scholar]
- Treatment of triple fracture of the superior shoulder suspensory complex. Journal of the Korean Orthopaedic Association. 2011;46(1)
- [Google Scholar]
- Coracoid fractures: therapeutic strategy and surgical outcomes. J Trauma Acute Care Surg. Feb. 2012;72(2):E20-E26.
- [Google Scholar]
- Triple disruption of the superior shoulder suspensory complex. Int J Shoulder Surg. Apr. 2012;6(2):67-70.
- [Google Scholar]
- [Triple fracture of the shoulder suspensory complex] Rev Española Cirugía Ortopédica Traumatol. Sep-Oct 2013;57(5):371-374.
- [Google Scholar]
- Triple and quadruple disruptions of the superior shoulder suspensory complex. J Orthop Trauma. Jun. 2015;29(6):264-270.
- [Google Scholar]
- Triple disruption of the superior shoulder suspensory complex - a case report. J Orthop Case Rep. 2019;9(3):39-42.
- [Google Scholar]
- Anatomic restoration of triple disruption of the superior shoulder suspensory complex: a case report and review of the literature. Orthop Surg. Oct. 2020;12(5):1526-1530.
- [Google Scholar]
- Quadruple disruptions of the superior shoulder suspensory complex misdiagnosed as triple disruptions: a case report. Asian J Surg. Jan. 2022;45(1):512-513.
- [Google Scholar]

