Trigger finger release (TFR) is a commonly performed hand surgery procedure. Ultrasound-guided TFR offers a minimally invasive release while ensuring clear visualization under real-time imaging. This study aims at investigating the effectiveness and safety in patients who received such surgery.
Patients who received ultrasound-guided minimally invasive TFR at a university hospital operated by a single surgeon between June 2023 and May 2024 were reviewed retrospectively. Primary outcome was incidence of residual triggering and extension lag. Changes in QuickDASH score, pain scale and number of hand therapy sessions were also recorded as secondary outcome.
14 patients with 16 operated digits were included in the study. Mean age was 67.6 ± 10.4 years and 64.3 % were female. Operated digits ranged from grade 1 to 4 triggering. None of the patients reported residual triggering after surgery. There was improved but residual flexion contracture noted in 4 digits post-operatively. No digital nerve injury was observed. All patients reported reduction in pain (mean visual analogue scale reduction 5.1 ± 2.8) and demonstrated improvement in QuickDASH score (mean reduction 21.4 ± 14.3). Patients received on average 2.7 ± 1.4 sessions of physiotherapy and 2.9 ± 2.6 sessions of occupational therapy over a period of 4.9 ± 4.7 weeks before they were discharged.
Minimally invasive TFR under ultrasound guidance is safe and effective in improving the symptoms of triggering and pain. However, residual extension lag after release is not uncommon in this cohort of patients, especially in grade 4 triggering.
Keywords
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1 Introduction
Trigger finger release (TFR) has evolved significantly with the use of minimally invasive techniques, particularly under ultrasound guidance in recent years. While percutaneous trigger finger release was first introduced as early as 1958,1 it has since evolved with the development of various tools and techniques. Studies have demonstrated that percutaneous techniques yield high success rates and low complication rate, comparable to open surgical methods.2
Ultrasound-guided trigger finger release has gained further traction recently among the hand surgery community. Ultrasound offers clear visualization of superficial structures such as flexor tendons and are thus suitable as a modality of image guidance during TFR. It can also rule out other secondary causes of triggering such as ganglion cysts or abnormal features such as tendon nodule.3 Compared to open TFR, it provides faster recovery and less pain intensity, and is possible in multiple trigger fingers at the same setting.4 A recent systematic review reported an overall success rate of 97 % with minor complications such as hematomas, persistent pain and transient numbness.5 It was also shown to be superior to blind percutaneous release with lower DASH scores and faster return to normal activities.6
Despite the promising outcome, percutaneous TFR, even with ultrasound guidance, could still be complicated with flexor tendon lacerations, potential injury to neurovascular bundles and incomplete division of A1 pulley.7 Therefore, this article aims at reporting the clinical outcome of a series of patients who underwent ultrasound-guided TFR in a Chinese population to provide an updated account of such surgery.
2 Materials and methods
A retrospective review of the series of patients at a single university hospital by a single surgeon (M.M.T.C.) with ultrasound-guided minimally-invasive TFR performed from June 2023 to May 2024 was done. Patients who defaulted follow-up after the surgery, received non-ultrasound-guided TFR such as blind percutaneous needle release or open release surgery were excluded from the study.
All patients received the surgery under wide awake local anaesthesia no tourniquet (WALANT) technique in the operating room under aseptic technique and sterile draping. Local infiltration using 1 % lignocaine with 1:100,000 adrenaline was injected at the planned surgical incision site and over the A1 pulley of the involved digit. No tourniquet was used throughout the surgery. A diagnostic ultrasound scan was first performed on-table to mark the flexor tendon anatomy and rule out abnormal features such as tendon nodules and space-occupying lesions around the flexor sheath, using a 12 L probe on the GE Healthcare Venue Go ultrasound machine (Chicago, IL, USA). A stab incision of 3–5 mm was then made at the palmar crease, perpendicular to the direction of flexor tendon shown on the ultrasound image. The Kemis H1 single use sterile surgical knife (Newclip Technics, Nantes, France) was then employed into the incision. The surgical knife consists of a sharp surgical blade in between two longer blunt-tip limbs which would catch the soft tissue target to be released. The knife was advanced under real-time ultrasound guidance, which remains to be in-line but superficial to the flexor tendon at all times, until the two limbs catch the A1 pulley in between with the blade cutting through the pulley under ultrasound-guidance in an antegrade fashion. The patient was then asked to move the digits actively to confirm no residual triggering and improved active range of motion, before the surgical incision was cleaned and apposed with surgical tape strips (suture-less technique). All patients were discharged on the same day and referred to the outpatient physiotherapy and occupational therapy departments as per institution protocol for rehabilitation subsequently.
Background patient parameters including age, sex, involved hand and digit, prior steroid injection before surgical release, and grading of triggering were recorded. Primary outcomes included the incidence of residual triggering and flexion contracture in the proximal interphalangeal joint (PIPJ). Secondary outcomes included incidence of complications if any, change in the QuickDASH score, pain score in visual analogue scale (VAS), and number of hand therapy sessions in physiotherapy and occupational therapy. Standard descriptive statistics were employed for analysis of categorical and continuous variables.
3 Results
A total of 14 patients with 16 digits were found to fit in the inclusion criteria. The mean age was 67.6 ± 10.4 years (range 55–88). Background parameters of operated patients and digits were illustrated in Table 1.
| Variable | n (%) | |
| Sex | Male | 5 (35.7 %) |
| Female | 9 (64.3 %) | |
| Operated hand | Left | 9 (64.3 %) |
| Right | 5 (35.7 %) | |
| Operated digit | Index | 1 (6.3 %) |
| Middle | 9 (56.2 %) | |
| Ring | 6 (37.5 %) | |
| Prior steroid injection | Yes | 7 (43.8 %) |
| No | 9 (56.2 %) | |
| Grade of triggering | 1 | 1 (6.3 %) |
| 2 | 6 (37.5 %) | |
| 3 | 1 (6.3 %) | |
| 4 | 8 (50.0 %) | |
In terms of outcome, all patients reported no residual triggering and were able to achieve full composite flexion of digits. The mean follow-up duration was 14.7 ± 15.9 weeks. There was residual PIPJ flexion contracture in 4 digits, who were all grade 4 pre-operatively with flexion contracture to begin. However, the degrees of flexion contracture improved compared to pre-operative measurement (patient 6: 20°–10°; patient 7: 30°–10°; patient 9: 30°–25°; patient 12: 20°–10°).
None of the patients reported any surgical complications, including hematoma, infection, or digital nerve injury. All patients reported improvement in QuickDASH score with the mean improvement being 21.4 ± 14.3 (Fig. 1). All patients also reported reduction in pain with the mean reduction in pain VAS score being 5.1 ± 2.8 out of 10 (Fig. 2). Patients were referred to outpatient physiotherapy and occupational therapy rehabilitation sessions routinely, and were discharged from therapy at 4.9 ± 4.7 weeks on average. They attend on average 2.7 ± 1.4 sessions of physiotherapy and 2.9 ± 2.6 sessions of occupational therapy throughout this period (Fig. 3). Of note, patient 1 suffered from rheumatoid arthritis with multiple finger joint deformity and pain concomitantly; and patient 7 & 8 suffered from multiple trigger finger and received two TFR in the same setting.



4 Discussion
The safety of percutaneous techniques, particularly concerning neurovascular structures, has been a focal point in the literature. Higher risk of digital nerve injury has been reported in cadaveric studies of blind percutaneous TFR, especially in the thumb and little finger due to the close proximity to the A1 pulley.8 However, ultrasound guidance enhances the safety of the procedure by providing real-time imaging, which helps avoid critical structures and ensures adequate release under image guidance.9 Amro et al. highlighted that complications such as nerve injury and infection, while possible, are significantly reduced with ultrasound guidance compared to open surgery.10 Most of the reports of digital nerve injury in ultrasound-guided TFR were transient neurapraxia with near complete resolution.5,11
Various tools have been developed for ultrasound-guided TFR. 18 or 21 gauge needles,12,13 needle knives,14 specially designed knives such as HAKI knives15 and V-lance knives.16 Some designs utilize the cutting edge of a blade (such as needles and needle knives) to simply divide the A1 pulley under image guidance with an attempt to reduce trauma to adjacent structures such as the underlying flexor tendon, while some designs utilize a back hook design incorporating a cutting blade between the hook to catch the A1 pulley first before cutting it, thereby minimizing trauma to adjacent soft tissue. The Kemis H1 knife used in this study is a new tool introduced to the author's locality, where it consists of two blunt-tip limbs to help isolate the A1 pulley to be caught without causing laceration to the flexor tendon, before transecting the A1 pulley longitudinally with the sharp blade in between the two limbs. This could be done either in an antegrade fashion or retrograde fashion. Because of the blunt tips of the limbs and a uniform plane of motion during the move of release, there is minimal risk of iatrogenic skin penetration compared to other hook devices.
In addition to the tools, the procedural techniques have been refined. Wu et al. explored the combination of ultrasound-guided needle release with corticosteroid injection, finding that this approach was more effective than needle release alone by narrowing thickness of A1 pulley.17 This combination therapy may address both the mechanical obstruction caused by the A1 pulley and the inflammatory component of trigger finger, leading to improved symptom relief and suggesting synergistic effect.
Patient satisfaction is a vital measure of treatment success. Studies have consistently reported high satisfaction rates following ultrasound-guided procedures. Yavari et al. demonstrated a higher patient satisfaction rate in ultrasound-guided percutaneous surgery compared to open release (94.1 % vs 76.4 %).4 Ultrasound-guided release could also be performed in the outpatient clinic setting under local anaesthesia18 with immediate return to daily activities, which further lowers hospital resources and manpower required for inpatient operating room setting.
There are several limitations to this study, being a retrospective review of a case series with a relatively small number of subjects. Only one instrument design is utilized so the results can only be drawn to this certain tool. Comparison with open surgical release will be done in a future study to look for differences in the mentioned outcomes.
5 Conclusion
This is the first report in the literature of using Kemis H1 knife in a Chinese population for ultrasound-guided TFR. Minimally invasive TFR under ultrasound guidance is safe and effective in improving the symptoms of triggering and pain. All patients reported improved functional outcome and pain score, without residual triggering symptoms. However, residual extension lag after release is not uncommon in this cohort of patients, especially in grade 4 triggering.
Informed consent statement
Informed consent was obtained from the patients before the surgery for teaching and academic purposes as per institutional policies.
Ethical statement
Strict adherence to confidentiality and anonymity of the patients was ensured as part of compliance with ethical standards, and the principles of Helsinki declaration were followed. Ethical approval was waived by the local institution review board for retrospective review of data in a case series.
Author contribution
M.M.T.C. is the sole author of this article and is responsible for conceptualization and writing of the manuscript.
Funding
No funding or financial assistance were obtained from any source in conducting this study or preparing the manuscript.
References
- Surgical treatment of trigger-finger by a subcutaneous method. J Bone Joint Surg Am. 1958;40-a(4):793-795.
- [Google Scholar]
- Percutaneous release, open surgery, or corticosteroid injection, which is the best treatment method for trigger digits? Clin Orthop Relat Res. 2013;471(6):1879-1886.
- [Google Scholar]
- Adult presentation of locked ‘congenital’ trigger thumb: a case report. International Journal of Surgery Case Reports. 2023;111
- [Google Scholar]
- Clinical study between percutaneous ultrasound-guided release and open classic surgery in treating multiple trigger fingers. Adv Biomed Res. 2023;12:88.
- [Google Scholar]
- Ultrasound-guided A1 pulley release: a systematic review. J Ultrasound Med. 2023;42(11):2491-2499.
- [Google Scholar]
- Ultrasound-guided vs. non-guided trigger finger release: a systematic review and meta-analysis. Int Orthop. 2024;48(9):2429-2437.
- [Google Scholar]
- Ultrasound-assisted percutaneous trigger finger release: is it safe? Hand. 2009;4(1):35-37.
- [Google Scholar]
- Percutaneous A1 pulley release: a cadaveric study. J Hand Surg. 1995;20(5):781-784.
- [Google Scholar]
- A comparison of blinded versus ultrasound-guided limited-open trigger finger release using the yasunaga knife. J Hand Surg Asian Pac. 2022;27(1):124-129.
- [Google Scholar]
- Efficacy of ultrasound-guided tendon release for trigger finger compared with open surgery: a systematic review and meta-analysis. J Ultrasound Med. 2024;43(4):657-669.
- [Google Scholar]
- Assessment of short-term response and review of technique of ultrasound-guided percutaneous A1 pulley release for the treatment of trigger finger. J Med Imaging Radiat Oncol. 2021;65(6):672-677.
- [Google Scholar]
- US-guided percutaneous release of the trigger finger by using a 21-gauge needle: a prospective study of 60 cases. Radiology. 2016;280(2):493-499.
- [Google Scholar]
- Evaluation of percutaneous first annular pulley release: efficacy and complications in a perfused cadaveric study. J Hand Surg Am. 2016;41(7):e165-e173.
- [Google Scholar]
- Ultrasound-guided percutaneous release of A1 pulley by using a needle knife: a prospective study of 41 cases. Front Pharmacol. 2019;10:267.
- [Google Scholar]
- Comparative study of ultrasonography-guided percutaneous A1 pulley release versus blinded percutaneous A1 pulley release. J Orthop Surg. 2018;26(2)
- [Google Scholar]
- Comparative clinical study of ultrasound-guided A1 pulley release vs open surgical intervention in the treatment of trigger finger. World J Orthoped. 2017;8(2):163-169.
- [Google Scholar]
- Ultrasound-guided needle release of A1 pulley combined with corticosteroid injection is more effective than ultrasound-guided needle release alone in the treatment of trigger finger. BMC Surg. 2022;22(1):221.
- [Google Scholar]
- Retrograde percutaneous release of trigger finger or thumb using sono-instruments®: detailed technique, pearls, and pitfalls. Cureus. 2024;16(1)
- [Google Scholar]