Research Article
2025
:4;
100367
doi:
10.1016/j.jorep.2024.100367

Translate:

Unstable inter-trochanteric femur fracture fixation with PFNA2: Does not require lateral wall fixation - A study of 278 patients

Author affiliations
P.D. Hinduja Hospital and Medical Research Centre, Mumbai, India
Article History
Corresponding author(s)

⁎Corresponding author: Vivek Shetty. vivshettydata@gmail.com

Article tools · PDF & citations

Abstract

Abstract

Lateral wall fracture was considered to be one of the major contributors to failure when such fractures were routinely treated with Sliding hip screw. Later, several publications stressed that the Intramedullary device (IM) is the implant of choice in such cases. Hence PFNA2 became the implant of choice in Asian population for unstable IT fracture since the last decade. But failures With this background we have assessed our results of last 5 years where PFNA2 was the only implant used for all IT fractures irrespective of comminution and stability.

This is a retrospective analysis of 309 patients with 3 part and 4 part stable and unstable IT fractures between June 2008 to June 2022 fixed with PFNA2 only, without additional fixation of the lateral wall.

All fractures united at an average of 14 weeks, without significant differences between the two groups (with and without lateral wall fracture). There was no statistically significant difference between the two groups with respect to TAD<20mm (p = 0.24), neck-shaft valgus angle at time of fixation (p = 0.31). There was no statistical significance between the two with respect to union rates, fracture collapse (p = 0.41), change in neck shaft angle (p = 0.11) and change in TAD (p = 0.44) between the surgery and at the time of union. Two patients presenting with implant failures (one done elsewhere) were revised and fixed with our technique with a PFNA2, without any lateral augmentation, both went on to unite well.

Well aligned antero-medial cortex, coupled with a valgus reduction of the neck shaft angle, helical blade in centre-centre and TAD˂20mm, the fixation of lateral wall has no role in preventing the fracture collapse nor in the healing of an unstable IT femur fractures.

Keywords

  • Intertrochanteric fracture
  • Unstable
  • Lateral wall
  • Anteromedial cortex
  • PFNA2
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Modern medicine has undergone significant advancements in the past century, resulting in an increased life expectancy.1,2 With that, the incidence of geriatric fractures has also gone up significantly. Inter-trochanteric (IT) femur fractures primarily occur in elderly individuals,3 leading to substantial morbidity. Despite advancements in orthopaedic surgery, unstable fractures continue to present challenges. Post-traumatic mortality rates are high, with 8–10 % of patients dying within one month and 20–28 % within one year.4,5

IT fractures have traditionally been classified based on posteromedial cortex comminution, reverse oblique fractures, and subtrochanteric extensions.6–9 Common complications associated with intramedullary (IM) fixation, such as screw cut outs, back outs, varus collapse, and fractures distal to the tip of the nail, are also seen with sliding hip screw (SHS). The correlation between cut outs and the TAD, as well as the placement of the screw in the head, was later discovered to be due to the unstable nature of the fracture and the need for adequate reduction. Varus fixations and medialization of the shaft increase the likelihood of complications, particularly in unstable fracture patterns.10,11

Gotfried in 2004 was the first to recognize the importance of the lateral wall in predicting the outcome of fracture fixation with SHS.12 Palm et al., in 2007 defined the lateral wall as the lateral femoral cortex distal to the vastus ridge.13 Rehan ul Haq [Fig. 1a]14 and Hsu et al. [Fig. 1b]15 later emphasized the relevance of the lateral wall. Overall, the integrity of the lateral wall has been shown to be a significant factor in the success of fracture fixation.

a) Lateral wall by Rehan et al.,14 b) Thickness of lateral wall by Hsu et al.15
Fig. 1 a) Lateral wall by Rehan et al.,14 b) Thickness of lateral wall by Hsu et al.15

James Carr in 2007 emphasized that the fixation of an IT fracture should depend on the continuity of the anterior and medial cortex, and the final result is solely determined by achieving a good reduction during the surgery.16 Haidukewych GJ in 2010 provided ten tips to improve the outcomes of IT fractures, including nailing in unstable fractures and prevention of varus alignment.17

For unstable IT fractures with lateral wall fractures, many authors from South-East Asia have recommended augmenting the lateral wall with a trochanteric buttress plate, cerclage of the greater trochanter, and additional screw fixation along with an IM device,18–21 or even primary hemiarthroplasty or total arthroplasty of the hip joint.22–25 Our study aimed to determine whether fixing a fractured lateral wall with a PFNA2 leads to different outcomes and whether augmenting it with a plate or screw can enhance the results of an unstable IT fracture.

2

2 Aims

To assess the difference in outcomes of unstable IT fractures with and without deficient lateral cortex fixed with PFNA2 alone.

3

3 Materials and methodology

In this study, 309 patients who were treated with PFNA2 for 3-part or 4-part unstable IT fractures (AO/OTA 31A2 and 31A3 type) at a tertiary referral center by a single orthopedic surgeon were analyzed. The data was collected from the Electronic Medical Records Department (EMRD) and included information on demographics, fracture classification, morphology, and stability. The patients were followed up at regular intervals starting from 3 weeks to 6 weeks, 3 months, 6 months, and then annually from June 2008 to June 2022. Only patients with complete follow-up for at least one year were included in the study, which included fresh fractures, non-unions, and implant failures after approval from the hospital's ethical committee.

Pre-operative and post-operative serial X-rays were collected from the hospital's PACS software (Picture Archiving and Communication System), and operative notes were thoroughly examined. Clinical notes on the progress of healing and rehabilitation were also recorded. The fractures were classified according to the AO Classification, and the positions of the helical blade in the head were assessed using Cleveland's index 26 in lateral views. The Baumgartner's method11 was used to assess the tip apex distance (TAD) for each patient in both the anteroposterior view and lateral view (Fig. 2).

a) Cleveland's Index,26 b) and c) Baumgartner's method.11
Fig. 2 a) Cleveland's Index,26 b) and c) Baumgartner's method.11

Measurements of the neck and shaft centers, as well as the angle subtended, were taken on immediate post-operative radiographs using computer software. These measurements were conducted both at the time of fracture fixation and at the time of union. The fracture collapse was measured as the change in distance from the inferior base of the helical blade to the lateral surface of the nail, taking into account the amount of proximal migration or backout of the helical blade. This was done on a magnified, adjusted standard 15-degree internal rotation AP view of the hip joint with the femur [Fig. 3]. All measurements were taken on immediate post-operative radiographs using computer software, marking the centers of the neck and shafts, and the angle subtended was measured both at the time of fracture fixation and at union [Fig. 3]. Fracture collapse was measured as the change in distance from the inferior base of the helical blade to the lateral surface of the nail, considering the amount of proximal migration or backout of the helical blade, on a magnified, adjusted standard 15-degree internal rotation AP view of the hip joint with the femur [Fig. 3].

Measurement of collapse and neck shaft angle a) on POD1, b) 6months. b) 6 months.
Fig. 3 Measurement of collapse and neck shaft angle a) on POD1, b) 6months. b) 6 months.
3.1

3.1 Surgical technique

Preparation on the fracture table was carried out as per standard protocol with the patient lying supine on the table [Fig. 4a&b]. Closed reduction was attempted and evaluated under fluoroscopy in both AP and lateral views [Fig. 5a&b]. Aseptic precautions were taken, and two incisions, each 2–3cm long, were made for the entry point of the nail and the helical blade [Fig. 4c]. In all cases, a 10mm diameter long nail [Fig. 5d,e&f] was used, with the length variable in most cases. A special reduction hook was employed to achieve perfect reduction in both AP and lateral views [Fig. 6i]. This hook was inserted through either of the two previously made incisions [Fig. 6b&c].

Position.
Fig. 4 Position.
Surgical technique.
Fig. 5 Surgical technique.
Various reduction techniques used in different cases. [ a) AP view of a reverse oblique fracture, b) hook probe used from inferior incision to achieve valgus, c) hook probe used from superior incision, d) collinear clamp with k-wires, e) & f) hook probe used for reduction in lateral view, g) Fixing with k-wires in AP view & h) Lateral view with anterior K-wires].
Fig. 6 Various reduction techniques used in different cases. [ a) AP view of a reverse oblique fracture, b) hook probe used from inferior incision to achieve valgus, c) hook probe used from superior incision, d) collinear clamp with k-wires, e) & f) hook probe used for reduction in lateral view, g) Fixing with k-wires in AP view & h) Lateral view with anterior K-wires].

The aim of reduction in the AP view was to either anatomically reduce the fracture or lateralize the shaft27 [Fig. 5d,e,g & 6c,d,g]. In the lateral view, the anterior cortical continuity was emphasized [Fig. 5f&h,6e,f&h], and a deliberate attempt was made to valgus the neck-shaft angle in every case [Fig. 6b,c&d]. For the helical blade, the aim was to insert the TAD less than 20mm in every case, targeting the subchondral bone in the center-center position (Cleveland zones 5 & 2)26 [Fig. 5g&f]. No attempt was made to fix the lateral wall. Medial calcar alignment in the AP view (lateralization or zero reduction)27 [Fig. 5d,e,g & 6c,d,g], anterior cortical alignment in the lateral view [Fig. 5f&h,6e,f&h], and a deliberate attempt to achieve a valgus neck-shaft angle (slightly greater than the normal side) [Fig. 6b,c&d] were made in every case.

Patients were allowed to bear weight and walk with a walker support from the day after surgery. Follow-up appointments were scheduled at two weeks for suture removal and then serially at 6 weeks, 3 months, and 6 months for a minimum of one year to assess union and collapse.

4

4 Results

A total of 309 patients with 3-part, 4-part, and reverse oblique IT fractures were enrolled in our study between June 2008 and June 2022. These patients were treated with PFNA2 without additional fixation of the lateral wall. However, 8 patients passed away during hospitalization due to associated co-morbidities, 7 within 3 months post-surgery, and 16 were lost to follow-up before solid union was achieved. These patients were excluded from the study. The remaining 278 patients were divided into two groups based on the integrity of the lateral wall: GROUP A (n = 114) with a fractured lateral wall and GROUP B (n = 164) with an intact lateral wall. Of these 278 patients, 155 (55.7 %) were females and 123 (44.2 %) were males, with a mean age of 77.4 (+8.01) and 71.55 (+23.7) years in GROUP A and B, respectively. The ages of the patients ranged from 40 to 96 years. All fractures united within 14 weeks, and there were no significant differences in the radiological outcomes between the two groups. The distribution of fracture types in GROUP A and B is presented in Table 1.

Table 1 AO/OTA Classification distribution.
AO Fracture type GROUP A GROUP B
31A2.1 0 19
31A2.2 8 51
31A2.3 44 72
31A3.1 24 0
31A3.2 21 22
31A3.3 17 0

The helical blade was positioned in the center of the femoral head in the majority of cases, with 69 patients in Cleveland's zone two and 199 patients in zone five [Fig. 7] [Table 2]. The tip apex distance (TAD) was less than 20mm in all cases, with no significant difference (p = 0.24) between the two groups [Table 2]. There was no significant change in TAD until healing, with Group A showing a value of −0.19 + 0.5 mm and Group B showing a value of −0.18 + 0.4 mm (p = 0.44) [Table 2]. Additionally, there was no significant difference in fracture collapse until healing, with Group A showing a value of 1.80 + 0.25mm and Group B showing a value of 1.80 + 0.12mm (p = 0.41) [Table 2]. There was no statistically significant difference between the two groups in neck-shaft angles in degrees at the time of fracture fixation, with values of 131.5° + 2.92 for G°roup A and 132.12° + 2.37° for Group B (p = 0.31), and at fracture healing, with values of 131.1° + 3.2° for Group A and 132.0° + 2.5° for Group B (p = 0.11) [Table 2] [Figs. 8, 9 and 10].

Cleveland's Index count.
Fig. 7 Cleveland's Index count.
Table 2 Master table.
MASTER TABLE
Total Patients N = 309
Died 15
Lost to follow up 16
Included in the study n = 278
SEX Male Female
123 (44.2 %) 155(55.7 %)
Age 71.55 (±23.7) 77.4 (+8.01)
n = 278 GROUP A IT with Fractured Lateral Wall GROUP B IT with Intact Lateral Wall
Side involved Left-66 Right-48 Left-85 Right-79
Number n = 114 n = 164
Union rate (weeks) 14.70 + 1.14 14 ± 1.11 p = 0.0570
At Fixation At Union At Fixation At Union
TAD 15.01 ± 2 mm 14.26 ± 2 mm p > 0.05
15.01mm 15.2mm 14.26mm 14.44mm
p > 0.05 p > 0.05
Blade Position (Cleveland's Index) Zone 2 28 41 Chi Square 0.3429
Zone 3 0 3
Zone 5 82 117
Zone 6 4 3
Fracture Collapse (In mm) 1.8 ± 0.25mm 1.8 ± 0.13mm p > 0.05
Neck shaft angle 131.5° 131.1° 132.1° 132.0° p > 0.05
p > 0.05 p > 0.05
57yr/female 3-part fracture with lateral wall fracture. Preop pic, Post op, Union in 14 weeks & 3-years follow up of complete union.
Fig. 8 57yr/female 3-part fracture with lateral wall fracture. Preop pic, Post op, Union in 14 weeks & 3-years follow up of complete union.
57yr/female 3-part fracture with lateral wall fracture. The neck shaft angle on the immediate post op Xray was 133.5°, which had changed to 132.5° at 6 weeks and then remained constant to 132° even at 3 years follow-up. Similarly, the TAD at fixation was 5mm remained the same till 3 years. Collapse was measured by the sliding of the helical blade which was 7mm at the time of fixation and 8mm at 6 weeks, 14 weeks and then remained the same till final follow-up.
Fig. 9 57yr/female 3-part fracture with lateral wall fracture. The neck shaft angle on the immediate post op Xray was 133.5°, which had changed to 132.5° at 6 weeks and then remained constant to 132° even at 3 years follow-up. Similarly, the TAD at fixation was 5mm remained the same till 3 years. Collapse was measured by the sliding of the helical blade which was 7mm at the time of fixation and 8mm at 6 weeks, 14 weeks and then remained the same till final follow-up.
85yr/M 4-part fracture with lateral wall fracture. Preop, Post-op, union in 15 weeks & 4-years follow up with complete union.
Fig. 10 85yr/M 4-part fracture with lateral wall fracture. Preop, Post-op, union in 15 weeks & 4-years follow up with complete union.

Two patients experienced implant failures, one of whom had been operated on elsewhere. Both were included in Group A for fractured lateral walls. The first patient had a helical blade back-out on the 13th post-operative day due to severe osteoporosis and a large TAD, and was revised with a longer spiral blade with a smaller TAD (9 mm) to achieve a stronger sub-chondral bone hold, which united at 14 weeks [Fig. 11]. The second patient, also in Group A, had a non-union of the reverse oblique IT# due to a large postero-medial defect and presented with a broken nail after 10 months, and was revised with a larger diameter nail but shorter than the first (due to a previous total knee replacement on the same side) along with iliac crest bone graft and additional cerclage wire holding the lesser trochanter in the postero-medial defect, which united at 13 weeks [Fig. 12]. In both cases, no attempt was made to fix or augment the lateral cortex.

66yr/F presented on post-op day 13 with screw backout, revised with antero-medial reduction and longer blade with TAD = 9mm without fixation of lateral wall, united at 14 weeks with proximal migration of screw till head margin.
Fig. 11 66yr/F presented on post-op day 13 with screw backout, revised with antero-medial reduction and longer blade with TAD = 9mm without fixation of lateral wall, united at 14 weeks with proximal migration of screw till head margin.
72/F, Nail broke at 10 months due to large posteromedial defect, revised with bone grafting and cerclage wire for Lesser trochanter without fixation of lateral wall, which united at 13 weeks post-revision.
Fig. 12 72/F, Nail broke at 10 months due to large posteromedial defect, revised with bone grafting and cerclage wire for Lesser trochanter without fixation of lateral wall, which united at 13 weeks post-revision.

On day 3 of one case, a deep infection was detected through ultrasonography. Adequate debridement was performed, and the lateral wall was excised [Fig. 13]. Two patients experienced infections that eventually healed after 14 and 24 weeks of debridement and appropriate antibiotics, including culture sensitivity and specificity. We did not encounter any complications in our patients, such as screw cut out, back out, varus collapse, or uncontrolled fracture collapse.

84/F fixed with PFNA2, had wound discharge. USG showed collection, at 1 week debrided and Lateral wall excised (seemed to be infected). At 2 years the Lateral wall has seen to have reformed and fracture healed.
Fig. 13 84/F fixed with PFNA2, had wound discharge. USG showed collection, at 1 week debrided and Lateral wall excised (seemed to be infected). At 2 years the Lateral wall has seen to have reformed and fracture healed.

Unfortunately, two patients developed avascular necrosis of the femoral head and hip joint arthritis three years after the surgery. Although the fracture had healed by 13 weeks, the patient required implant removal and a dual mobility total hip replacement procedure a year later, which was four years post-primary fixation [Fig. 14].

65/Male 4-part lateral wall fracture fixed with PFNA2. Pre-op & Immediate Post-op Xrays with serial follow-ups, avascular necrosis of the femoral head seen at 2 years follow up and Dual Mobility THR done at 3.5 years follow up.
Fig. 14 65/Male 4-part lateral wall fracture fixed with PFNA2. Pre-op & Immediate Post-op Xrays with serial follow-ups, avascular necrosis of the femoral head seen at 2 years follow up and Dual Mobility THR done at 3.5 years follow up.
5

5 Discussion

The significance of an intact lateral femoral cortex fixed with a SHS system was well described by Gotfried as a buttress that prevents excessive collapse, screw cutout, shortening, and abductor function insufficiency.12 In reverse oblique fractures, the sliding vector of the proximal fragment is parallel to the SHS, which results in excessive collapse without any buttressing effect, as described by Tawari et al. and others.28–30,31

Many authors have advocated for the augmentation of the fractured lateral wall with a trochanteric stabilization plate associated with inter-trochanteric fractures in a SHS construct.18–20,32 Ganjale et al., Monesh et al., and Gadegone et al. have advocated the use of a trochanteric buttress plate with proximal femoral nail in cases with deficient lateral walls to achieve good outcomes,18–21 although these nails were an older design of AO/ASIF in 1996.33 Gadegone et al. and Kulkarni et al. have advocated for the augmentation with cerclage wires of the greater trochanter or adding an extra Lag screw with the proximal femoral nail.25,26

In our study, out of the 245 patients, there was no incidence of a helical blade cutout. As explained by Baumgartner, the TAD was aimed at less than 20 mm and positioned at the center-center (Clevelands index zone 5 and 2). A series of 340 patients by Yam et al.34 mentioned that screw cutout was based on both the helical blade placement and TAD>27mm. Another study of 3066 patients by Bojan et al. had 2.3 % (71 patients) and concluded that an anatomical reduction and appropriate screw placement are critical for a good outcome, which are surgeon-controlled.35 Our series shows that achieving a stable anterior and medial cortex continuity eliminates the chances of a cutout, even in cases of unstable fractures and lateral wall fractures.36

The degree of fracture collapse (reduction in the length of the bone) and the alteration in the angle of the bone shaft are also indicators of cut out rates and residual abductor lurch (limp) in patients, as reported by Helin et al. in a series of 115 patients.32 The study found that unstable fractures had a statistically significant collapse of 8.1 ± 8.4 mm, while stable fractures had a collapse of 1.8 mm on average. The blade position was found to be effective in reducing the risk of cut outs and fracture collapse in multiple studies, including those by Simmermacher et al., Herman et al., and others.37,38

A study by Kjell Matre et al., in 2013, which included 684 patients with IT fractures treated with either an IM device or SHS, showed no significant difference in pain and functional outcomes between the two groups. However, the SHS group that had unstable IT fractures were all augmented with a trochanteric buttress plate, which may have contributed to the lack of significant difference in outcomes.

The most common complications encountered in our series were non-union and mal-union, which were not observed in our cases.39 Two cases of implant failure were identified, one of which had a blade back out with a TAD >20mm [Fig. 11], and was revised using our technique with a TAD of 9mm and no lateral wall stabilization was attempted. The other case of implant failure had a medial cortex void, which was addressed with a revised nail and cerclage of the lesser trochanter, with bone grafting to fill the medial cortex void [Fig. 12]. Both of these fractures healed without addressing the lateral wall [Figs. 11 and 12]. The third complication was a deep infection, which was treated with debridement and excision of the lateral wall. This patient also achieved union and the lateral wall was reformed at the final follow-up. No implant-related complications were observed in the last case [Fig. 13]. Two fracture-related complications were identified, where the fractures united, but avascular necrosis (AVN) of the head was observed approximately 2 years later. Both cases were revised to a Dual Mobility Total Hip Replacement[Fig. 14].

Other common complications seen in the literature, such as screw or helical blade cut-out and back-out, were not observed in our series18,21,.39 We emphasize the importance of reduction in the lateral view (anterior cortex) in achieving a stable reduction, as it plays a crucial role in preventing cut-out or back-out of the helical blade. Good medial cortex continuity also contributes to the overall stability of the reduction.

Compared to previous studies by Aguado et al., Gadegone et al., and Monesh et al., our study had a complication rate of less than 2 %, which is significantly lower than the 5–13 % reported in those studies. We believe that our focus on reducing the anterior cortex in the lateral view, in addition to the reduction in the AP view, was just as important as the reduction in the AP view and made a significant difference in our outcomes. Our study was based on the principles emphasized by James Carr, Yoon YC, Baumgartner MR, Haidukewych GJ, and others, which emphasize the importance of aligning the anterior and medial cortex and restoring the valgus angle and TAD<20mm. Yoon YC et al. also highlighted the significance of anteromedial cortical continuity in both the AP and lateral views, and the restoration of the neck shaft angle during surgery to achieve optimal outcomes for IT fractures treated with PFNA2. It is worth noting that most of the criteria for optimal intraoperative reduction mentioned by Yoon YC et al. were already being followed in our fixations, without the need for additional augmentation for the lateral cortex. Although the proximal femoral nail functions as a prosthetic lateral wall even if the native lateral wall is fractured, as explained by Kokoroghiannis, the intramedullary nature of the nail prevents the medialization of the distal fragment.

Limitations of the study - The two limitations of the study were that it was retrospective in nature and functional outcomes were not evaluated.

6

6 Conclusion

-All unstable IT femur fractures with fractured lateral wall can be fixed with PFNA2, without any need for augmentation of lateral wall, if the following are strictly followed--Aligned anterior cortex in the lateral view should be stressed upon. (important in prevention of progression of collapse at fracture site).-Neutral or positive reduction for the medial cortices.-Valgus reduction always, irrespective of the neck shaft angle on the opposite side.-Helical blade in centre-centre position only with TAD<20mm or lesser in osteoporotic patients.-All the fractures united and complications like screw back out, varus collapse were not seen in our study.

Ethical approval statement

The institutional ethics committee approved the study.

Patient consent

All patients gave written informed consent before inclusion in the study.

Funding

None.

Author contribution

Vivek Shetty (VS): Conceptualisation, Supervision, Analysis.

Vikas Agashe (VA): Conceptualisation, Supervision.

Sajeev Shekhar (SS): Data Collection, Manuscript writing.

Shaswat Mishra (SM): Data Collection, Manuscript writing.

Kailash M Jorule (KJ): Data analysis.

Suhas Landge (SL): Data analysis.

References

  1. , . Does modern medicine increase life-expectancy: quest for the Moon Rabbit? Indian Heart J. Jan. 01, 2016;68(1):19-27.
    [Google Scholar]
  2. , . The role of medical care in contributing to health improvements within societies. Int J Epidemiol. Dec. 01, 2001;30(6):1260-1263.
    [Google Scholar]
  3. , , , , , , . A prospective study on socioeconomic aspects of fracture of the proximal femur. J Bone Miner Res. 1996;11(12):1935-1942.
    [Google Scholar]
  4. , , . An estimate of the worldwide prevalence, mortality and disability associated with hip fracture. Osteoporos Int. Nov. 2004;15(11):897-902.
    [Google Scholar]
  5. , , , . Mortality and morbidity after hip fractures. Br Med J. 1993;307(6914):1248-1260.
    [Google Scholar]
  6. , . Classification of trochanteric fractures. Acta Orthop. 1980;51(1–6):803-810.
    [Google Scholar]
  7. , . The treatment of trochanteric fractures of the femur. J. Bone Joint Surg. Br.. May 1949;31(2):190-203.
    [Google Scholar]
  8. , , , , , . Fracture and dislocation classification compendium—2018. J Orthop Trauma. Jan. 2018;32:S1-S10.
    [Google Scholar]
  9. , , , , , , . Critical factors in cut-out complication after gamma nail treatment of proximal femoral fractures. BMC Muscoskel Disord. Jan. 2013;14(1):1-9.
    [Google Scholar]
  10. , , , , . The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J. Bone Jt. Surg. - Ser. A. 1995;77(7):1058-1064.
    [Google Scholar]
  11. , . The lateral trochanteric wall: a key element in the reconstruction of unstable pertrochanteric hip fractures. Clin Orthop Relat Res. Aug. 2004;425(425):82-86.
    [Google Scholar]
  12. , , , , . Integrity of the lateral femoral wall in intertrochanteric hip fractures: an important predictor of a reoperation. J. Bone Jt. Surg. - Ser. A. 2007;89(3):470-475.
    [Google Scholar]
  13. , , , , , , . Proximal femoral nails compared with reverse distal femoral locking plates in intertrochanteric fractures with a compromised lateral wall; a randomised controlled trial. Int Orthop. 2014;38(7):1443-1449.
    [Google Scholar]
  14. , , , , . Lateral femoral wall thickness: a reliable predictor of post-operative lateral wall fracture in intertrochanteric fractures. Bone Jt. J.. 2013;95 B(8):1134-1138.
    [Google Scholar]
  15. , . The anterior and medial reduction of intertrochanteric fractures: a simple method to obtain a stable reduction. J Orthop Trauma. Aug. 2007;21(7):485-489.
    [Google Scholar]
  16. , . Intertrochanteric fractures: ten tips to improve results. Instr Course Lect. 2010;59:503-509.
    [Google Scholar]
  17. , , , . Trochanteric buttress plate combined with proximal femoral nail for unstable intertrochanteric fractures. [Innovative technique] Open J Orthoped. 2018;8(6):235-247.
    [Google Scholar]
  18. , , , , . Augmentation of proximal femoral nail in unstable trochanteric fractures. Sicot-J. 2017;3:12.
    [Google Scholar]
  19. , , , , , , . Augmentation of intramedullary nailing in unstable intertrochanteric fractures using cerclage wire and lag screws: a comparative study. Injury. 2017;48(6):S18-S22.
    [Google Scholar]
  20. , , , , . A solution to z effect and lateral wall comminution in nailing of per trochanteric fractures: a retrospective study of 54 cases. Int. J. Orthop. Sci.. 2019;5(2):1134-1137.
    [Google Scholar]
  21. , , , , . How to treat the complex unstable intertrochanteric fractures in elderly patients? DHS or arthroplasty. Arch. Bone Jt. Surg.. Sep. 2014;2(3):174-179.
    [Google Scholar]
  22. , , , , , , . Primary hemiarthroplasty for unstable osteoporotic intertrochanteric fractures in the elderly: a retrospective case series. Indian J Orthop. Oct. 2010;44(4):428-434.
    [Google Scholar]
  23. , , , , . Cemented hip arthroplasty with a novel cerclage cable technique for unstable intertrochanteric hip fractures. J Arthroplasty. Apr. 2005;20(3):337-343.
    [Google Scholar]
  24. , , , , . Total hip replacement as primary treatment of unstable intertrochanteric fractures in elderly patients. Int Orthop. Aug. 2010;34(6):789-792.
    [Google Scholar]
  25. , , , , , . A ten-year analysis of intertrochanteric fractures of the femur. PubMed J Bone Joint Surg Am. 1959;41(A):1399-1408.
    [Google Scholar]
  26. , , , , , , . Fracture reduction with positive medial cortical support: a key element in stability reconstruction for the unstable pertrochanteric hip fractures. Arch Orthop Trauma Surg. Jun. 2015;135(6):811-818.
    [Google Scholar]
  27. , , , , . What makes an intertrochanteric fracture unstable in 2015? Does the lateral wall play a role in the decision matrix? J Orthop Trauma. Apr. 2015;29(4):S4-S9.
    [Google Scholar]
  28. , , , . Reverse obliquity fractures of the intertrochanteric region of the femur. J. Bone Jt. Surg. - Ser. A. 2001;83(5):643-650.
    [Google Scholar]
  29. , , , , , , . Treatment of reverse oblique and transverse intertrochanteric fractures with use of an intramedullary nail or a 95° screw-plate: a prospective, randomized study. J. Bone Jt. Surg. - Ser. A. Mar. 2002;84(3):372-381.
    [Google Scholar]
  30. , . Prospective study of prognosis of intertrochanteric fractures with lateral wall involvement as compared to intertrochanteric fractures with intact lateral wall. Int. J. Res. Orthop.. Dec. 2019;6(1):129.
    [Google Scholar]
  31. , , , , , , . Does the PFNATM nail limit impaction in unstable intertrochanteric femoral fracture? A 115 case-control series. Orthop. Traumatol. Surg. Res.. Feb. 2015;101(1):45-49.
    [Google Scholar]
  32. , , , , , , . The proximal femoral nail (PFN) - a minimal invasive treatment of unstable proximal femoral fractures: a prospective study of 55 patients with a follow-up of 15 months. Acta Orthop Scand. Feb. 2003;74(1):53-58.
    [Google Scholar]
  33. , , , . Rewriting the tip apex distance for the proximal femoral nail anti-rotation. Injury. Aug. 2017;48(8):1843-1847.
    [Google Scholar]
  34. , , , , , , . Critical factors in cut-out complication after gamma nail treatment of proximal femoral fractures. BMC Muscoskel Disord. Jan. 2013;14(1):1-9.
    [Google Scholar]
  35. , , . Early complications associated with cephalomedullary nail for intertrochanteric hip fractures. J Trauma Acute Care Surg. Feb. 2012;72(2)
    [Google Scholar]
  36. , et al . The new proximal femoral nail antirotation (PFNA®) in daily practice: results of a multicentre clinical study. Injury. Aug. 2008;39(8):932-939.
    [Google Scholar]
  37. , , , , , , . Radiological evaluation of intertrochanteric fracture fixation by the proximal femoral nail. Injury. Jun. 2012;43(6):856-863.
    [Google Scholar]
  38. , et al . Results and complications of pertrochanteric hip fractures using an intramedullary nail with a helical blade (proximal femoral nail antirotation) in 200 patients. Rev. Española Cirugía Ortopédica y Traumatol. (English Ed.. May 2013;57(3):201-207.
    [Google Scholar]
Show Sections