Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Case Report
2023
:2;
100152
doi:
10.1016/j.jorep.2023.100152

Translate:

Use of non-absorbable suture for stabilizing pubic diastasis in a child – Case report with review of literature

Author affiliations
Department of Orthopaedics & Spine Surgery, Ganga Hospital, Coimbatore, India
Article History
Corresponding author(s)

∗Corresponding author: K. Venkatadass. vk@gangahospital.net

Article tools · PDF & citations

Abstract

Abstract

Pelvic injuries in the paediatric population are relatively rare and thus there are scanty reports in the literature about their management. Traditionally these injuries were managed conservatively; however, recent studies have shown more inclination towards operative management because of the limited remodeling potential.

In this report, we describe an uncommon, unstable pelvic injury in a 5-year-old child which needed open reduction and stabilization of the pubic symphysis.

We report a rare injury, management, and innovative technique of stabilization of the pubic symphysis in a 5-year-old child. We recommend adding non-absorbable sutures to the armamentarium for the management of paediatric pelvic injuries.

Keywords

  • Pelvic injury
  • Paediatric
  • Fibre wire
  • Suture
  • Pubic
  • Diastasis
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Pelvic injuries in the paediatric population are relatively uncommon. The most common causes include high-velocity injury like a road traffic accident or fall from height. Children have higher plasticity of the pelvic bones, thicker cartilage, and increased elasticity of the symphysis pubis and Sacro-iliac joints, and thereby a higher mechanism of injury is required to cause a fracture in the paediatric pelvis. The increased force required to cause a fracture thereby also causes significant surrounding soft tissue injury. Though there are many classification systems like Young-Burgess, Torode and Zeig, and AO/Tile/OTA classification in the literature, none of them guide the appropriate management. The literature is very scarce on the management guidelines for these injuries because of the rarity of these injuries in the paediatric population.

Historically, paediatric pelvic injuries were managed conservatively. However, recent studies demonstrated the limited ability of the pelvis to remodel and thereby warrants appropriate reduction and stabilization. In this report, we describe a rare pelvic injury in a child, its management, and the outcome.

2

2 Case report

A 5-year-old male child presented to our emergency room with an alleged history of a fall from the bus. The child was initially taken to a local hospital for primary management and later brought here 6 ​h after the injury. The patient sustained an injury to the pelvis and left hip and was not able to stand or walk after the injury. There was no history of loss of consciousness, vomiting, or seizures.

On initial evaluation, he was conscious and oriented but was found to be hemodynamically unstable with tachycardia and hypotension. There was no associated injury to the head or face. There was no associated vascular injury or neurological deficit. The child was able to move all his extremities except the left lower limb due to pain. On examination, he had some abrasions over the anterior aspect of the left groin. There was diffuse swelling present over the groin area and over the left hip. Severe tenderness was present over the left hip. The Pelvic compression test was found to be positive. The initial diagnostic radiographs were advised which showed pubic diastasis with bilateral SI Joint disruption and fractured neck of the femur left side (Fig-1). The patient was stabilized first with IV Fluids and a temporary pelvic binder. The patient was catheterized to rule out associated urethral or bladder injury. After hemodynamic stabilization, a whole-body Computerized tomography scan was obtained which showed significant disruption of pubic symphysis with widening and mild opening of bilateral Sacro-iliac joints. There was no associated visceral organ injury. Also, there was a displaced comminuted fracture of the posterior iliac bone and an undisplaced fracture involving the left neck of the femur and right superior pubic ramus (Fig-2).

Pre-operative radiograph of pelvis with both hips showing left neck of femur un-displaced unicortical fracture with pubic diastasis with bilateral Sacro-iliac joint disruption.
Fig. 1 Pre-operative radiograph of pelvis with both hips showing left neck of femur un-displaced unicortical fracture with pubic diastasis with bilateral Sacro-iliac joint disruption.
Pre-operative computerized tomography scan of the pelvis. (A, B, C) Coronal & Axial cuts showing bilateral SI Joint disruption with widening more on the left with severe comminution of the posterior iliac bone with displacement on the left side. (D, E) Sagittal and coronal cuts showing undisplaced neck of femur fracture. (F, G) 3D Reconstructed images showing severe widening of pubic symphysis with bilateral SI Joint Disruption.
Fig. 2 Pre-operative computerized tomography scan of the pelvis. (A, B, C) Coronal & Axial cuts showing bilateral SI Joint disruption with widening more on the left with severe comminution of the posterior iliac bone with displacement on the left side. (D, E) Sagittal and coronal cuts showing undisplaced neck of femur fracture. (F, G) 3D Reconstructed images showing severe widening of pubic symphysis with bilateral SI Joint Disruption.

After hemodynamic stabilization, he was planned for cancellous screw fixation of the left neck of the femur and stabilization of the pelvis with an external fixator and sacro-iliac screw fixation of the left SI joint. The neck of femur fracture was first stabilized with two 4.5mm cancellous screws. The pelvis was stabilized with an external fixator with two Schanz pins placed in the supra-acetabular region which was connected with the rods in the standard fashion and the left SI joint was fixed with a 6.5mm cannulated cancellous screw.

At this point, though the AP view of the pelvis showed satisfactory alignment of the symphysis pubis, the inlet view showed anteroposterior translation (Fig-3A). It was decided to proceed with open reduction and internal fixation of the symphysis pubis. The pubic symphysis was approached using the standard Pfannenstiel incision. The superficial subcutaneous tissue was dissected, and the anterior rectus fascia was identified. The linea alba was identified and incised longitudinally and both bellies of the rectus abdominis were retracted laterally to expose the symphysis pubis. The dissection was completed around the symphysis pubis with a blunt hemostat. The anteroposterior translation was corrected using a hook reduction clamp and Arthrex #2 FiberWire, 38″ was used to suture either of the cartilaginous ends of the symphysis pubis in a horizontal mattress pattern (Fig-3B, C). The surgical wound was then closed in layers. Post-operative radiographs showed satisfactory reduction and good alignment (Fig-4).

(A) Intra-operative fluoroscopy image showing the antero-posterior translation of pubic symphysis with over-riding (B) Intra-operative image showing opposing ends of pubic symphysis with Fibre wire in situ (C) Intraoperative fluoroscopy image showing correction of antero-posterior translation of pubic symphysis after Fibre wire suturing.
Fig. 3 (A) Intra-operative fluoroscopy image showing the antero-posterior translation of pubic symphysis with over-riding (B) Intra-operative image showing opposing ends of pubic symphysis with Fibre wire in situ (C) Intraoperative fluoroscopy image showing correction of antero-posterior translation of pubic symphysis after Fibre wire suturing.
Post-operative radiograph of pelvis AP, inlet & Outlet view showing satisfactory reduction and alignment.
Fig. 4 Post-operative radiograph of pelvis AP, inlet & Outlet view showing satisfactory reduction and alignment.

The patient was followed-up in the out-patient department at 6 weeks, 3 months, 6 months, and 1-year follow-up. The external fixator was removed at 6 weeks and the patient was allowed weight-bearing after 3 months. At 1 year follow-up, the radiological (Fig-5) and functional outcome was excellent. He was able to carry out all routine activities, able to sit cross-legged and squat, and has no complaints (Fig-6).

Radiograph of pelvis AP, inlet & Outlet view, and Frog leg lateral view at 1-year follow-up showing union & satisfactory alignment.
Fig. 5 Radiograph of pelvis AP, inlet & Outlet view, and Frog leg lateral view at 1-year follow-up showing union & satisfactory alignment.
Clinical Photograph of the child at 1-year follow-up showing the good functional outcome.
Fig. 6 Clinical Photograph of the child at 1-year follow-up showing the good functional outcome.
3

3 Discussion

Historically, paediatric pelvic injuries were managed with conservative, non-operative measures like skin/skeletal traction, hip spica, immobilization using a brace, and bed rest.1 However recent literature demonstrates an increasing role of operative management in the treatment of paediatric pelvic injuries especially unstable injuries.2,3 Because of the limited remodeling potential of the paediatric pelvis, it is preferable to achieve anatomical reduction and adequate stabilization even if it requires open reduction.

In children younger than 10 years of age, choosing an implant for stabilization can be difficult considering the small size of the bone, and potential effects on growth. An unstable SI joint can be fixed with plates or cancellous screws. In our patient, the SI joint was fixed with a percutaneous cancellous screw which is a safe effective method as described by the study done by Scolaro JA et al.4 Symphyseal disruption can be managed with external fixators, screw or cerclage, and dynamic compression plates. Although non-absorbable, braided sutures are extensively used in orthopedics, their use in paediatric pelvic injuries is not well described. There is only one study where they have described the use of suture for fixation of unstable pelvic injury in a two and ½-year-old child where they initially applied spica and 1 week later, the pelvis was still found to be unstable.5 The fiber wire is non-absorbable and strong enough to hold the pubic symphysis in place till it heals. The external fixator provides additional stability and a spica can be avoided for the child.

4

4 Conclusion

We report a rare injury, management, and innovative technique of stabilization of the pubic symphysis in a 5-year-old child. We suggest that non-absorbable sutures like Fibre wire or Ethibond is a good choice to fix the pubic symphysis in very young children and may be included in the armamentarium for the management of paediatric pelvic injuries.

Institutional review board

Approval taken.

Funding

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Declaration of conflicting interests

All the Authors declares that there is no conflict of interest.

Research ethics and patient consent

Written consent for publication of patient details were obtained from the parent/guardian.

Author's contribution statements

K Venkatadass - Conceptualization of the technique and surgeon who operated, reviewing the manuscript. Deepak Jain - Manuscript preparation, figures, literature review, artwork. Ilavarasan MD – Manuscript preparation, figures, literature review. S Rajasekaran - Reviewing and editing the manuscript.

References

  1. , , , , . Selective management of pediatric pelvic fractures: a conservative approach. J Pediatr Surg. 1987;22(6):538-540.
    [Google Scholar]
  2. , . Pelvic disruptions in children. Clin Orthop Relat Res. 1980;151:130-134.
    [Google Scholar]
  3. , , , , , , . Long-term results of unstable pelvic ring fractures in children. Injury. 1998;29(6):431-433.
    [Google Scholar]
  4. , , , . Treatment of pediatric and adolescent pelvic ring injuries with percutaneous screw placement. J Pediatr Orthop. 2018;38(3):133-137.
    [Google Scholar]
  5. , , , , . Suture fixation of a pediatric pelvic ring injury: a case report. JBJS Case Connect. 2021;11(4)
    [Google Scholar]
Show Sections