Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors
Search in posts
Search in pages
Filter by Categories
Case Report
Clinical Images
Research Article
Review Article
View/Download PDF
Research Article
2023
:2;
100162
doi:
10.1016/j.jorep.2023.100162

Translate:

Wide-awake local anesthesia No tourniquet (WALANT) for reconstruction of flexor pollicis longus ruptures following volar plate fixation of distal radius fractures- A Case series

Author affiliations
Olympia Hospital & Research Centre, Trichy, Tamilnadu, India
Article History
Corresponding author(s)

∗Corresponding author: J. Terrence Jose Jerome. terrencejose@gmail.com

Article tools · PDF & citations

Abstract

Abstract

The flexor pollicis longus tendon rupture following distal radius fractures is a known complication and reconstruction with interposition tendon graft achieved a good outcome. Therefore, this study aims to analyze the outcome of FPL tendon reconstruction using the wide-awake local anesthesia no tourniquet (WALANT) technique.

Seven patients with attritional FPL rupture were retrospectively analyzed between 2014 and 2021. All these patients had FPL reconstruction using palmaris longus interposition graft under WALANT. The patient demographics, Soong volar plate prominence classification, volar plate type, and functional outcome assessment were reviewed.

The FPL tendon rupture occurred at a mean of 1.1 years (range, 6 months −3 years) following volar plate fixation. The patients had T-buttress (n ​= ​6) and volar locking plates (n ​= ​1). The mean follow-up of our study was 16.5 months (range 12–19 months). The total interphalangeal joint movement, grip strength, pinch strength, and Kapandji score were significantly less than the uninjured hand (p ​< ​0.05). The mean DASH Score was 14 (range 4.5–28). All surgeries were daycare, and WALANT provided effective analgesia and a comfortable patient experience.

FPL reconstruction using WALANT achieves a good functional outcome. In addition, the intraoperative assessment of tendon excursion, adjusting the tension, and educating early rehabilitation are the advantages of the WALANT.

IV, Retrospective case study.

Keywords

  • FPL rupture
  • Volar plate distal radius fracture
  • Palmaris longus graft
  • WALANT
  • Good outcome
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

The flexor pollicis longus (FPL) attritional rupture following volar plate fixation is reported to occur in 0.3–5.6% of cases.1,2 Sub-optimal placement of the plate (distal to watershed line), abrasive (attrition) wear between the tendon and the plates, fracture collapse or plate displacement, plate lift-off, and poor plate coverage by pronator quadratus are some of the reasons for FPL rupture.1,2 The time taken for rupture may vary from 6 months to more than ten years.1–4 The FPL rupture ends, retracts, and becomes shortened. Therefore, the FPL reconstruction is performed by bridging tendon grafts or tendon transfer of the third or fourth flexor digitorum superficialis (FDS). In the past, FPL surgeries were performed under regional or general anesthesia with a tourniquet.1–4 The tendon gliding assessment and suture tension adjustments to ensure the proper functioning of the tendon intraoperatively are impossible.

The wide-awake local anesthesia without a tourniquet has become popular in tendon repair, tenolysis, and tendon transfers. For example, in distal radius fracture fixations, there are scars and adhesions around the plates and flexor tendons. Therefore, adjusting the tendon tension, appreciating the tendon excursion in the field of scar tissues, and checking the tenodesis action are advantageous for the WALANT. Additionally, wide-awake anesthesia allows the selection of adequate muscle by evaluating the musculotendinous units, thereby assisting in selecting the donor's tendons. Finally, the surgeon can choose tendon grafting or tendon transfer intra-operatively.

The study aimed to analyze the outcome of FPL reconstruction in the case of volar plate distal radius fractures attritional FPL ruptures using the WALANT technique.

2

2 Materials and methods

2.1

2.1 Patients, setting, and ethics

A retrospective study approved by the institutional ethical committee review board analyzed seven patients with attritional FPL rupture between 2014 and 2021.

Inclusion criteria: The study included FPL rupture following volar plate fixation of distal radius fractures operated using the WALANT technique.

Exclusion criteria: The study excluded flexor digitorum superficialis (FDS), flexor digitorum profundus (FDP) rupture, and acute and traumatic FPL tendon injuries.

The study noted the patient demographics, type of volar plate, Soong volar plate classifications, and time from fracture fixation to rupture. The clinical examination confirmed the FPL tendon rupture. In addition, the preoperative range of motion, grip strength, and pinch strength were recorded. The Soong et al.5 classification graded volar plate prominence on the lateral wrist view. The study collected the patient's data during their visit to the hospital and took pictures with consent (Figs. 1–5). All patients were kept from follow-up.

The clinical (A, B) and the radiological picture (C, D) of a 50-year-old man with left side FPL rupture following the distal radius fracture fixation.
Fig. 1 The clinical (A, B) and the radiological picture (C, D) of a 50-year-old man with left side FPL rupture following the distal radius fracture fixation.
Intra-operative pictures showing the screw prominence, plate lift-off (A), the gap between the rupture ends (B), and reconstruction of the FPL using palmaris longus free tendon graft (C).
Fig. 2 Intra-operative pictures showing the screw prominence, plate lift-off (A), the gap between the rupture ends (B), and reconstruction of the FPL using palmaris longus free tendon graft (C).
The follow-up clinical picture of the patient shows active flexion and extension movements of the left thumb.
Fig. 3 The follow-up clinical picture of the patient shows active flexion and extension movements of the left thumb.
The clinical (A) and the radiological picture (B, C) of a 20-year-old man with right side FPL rupture following the distal radius fracture fixation. The patient had an untreated 2nd metacarpophalangeal dislocation and fracture of the 3rd metacarpal shaft.
Fig. 4 The clinical (A) and the radiological picture (B, C) of a 20-year-old man with right side FPL rupture following the distal radius fracture fixation. The patient had an untreated 2nd metacarpophalangeal dislocation and fracture of the 3rd metacarpal shaft.
A- The intra-operative picture shows the plate and the ruptured FPL. B, C- follow-up clinical picture shows the flexion-extension movements in the right thumb.
Fig. 5 A- The intra-operative picture shows the plate and the ruptured FPL. B, C- follow-up clinical picture shows the flexion-extension movements in the right thumb.
2.2

2.2 FPL tendon reconstruction using the WALANT approach (Video 1)

Supplementary video related to this article can be found at https://doi.org/10.1016/j.jorep.2023.100162

The following is the supplementary data related to this article.Video S1The video demonstrates the surgical technique of FPL reconstruction using the WALANT technique in a patient with FPL rupture following distal radius fracture fixation.Video S1

The patient is supine on a stretcher to prevent vasovagal or fainting attacks. The flexor pollicis longus (FPL) and the distal radius containing the volar plate area are marked in the patient’s waiting room or the surgical preparation room. The purpose is to block the median and the ulnar nerve. The WALANT mixture contains 10 ​ml of 1% lidocaine with 1:100,000 epinephrine and 1 ​ml of 8.4% sodium bicarbonate.6,7 The maximum dose of infiltration is ​< ​7 ​mg/kg. The FPL reconstruction and volar plate removal usually require a 50 ​ml solution. In case when WALANT solution is required more (50–100 ​ml), the total dose is diluted with saline to a concentration of 0.5% with 1:200,000 epinephrine. A 25 or 27-gauze needle infiltrates under the skin and the distal and proximal forearm fascia, where 15–20 ​ml is injected. Up to 20 ​ml of the same solution goes in the palm, starting with 10 ​ml over the carpal tunnel, then 10 ​ml over the thenar eminence, and 2 ​ml in the thumb proximal phalanx injection point just under the skin on both sides to numb the digital nerves. The injected area becomes numb in about 15–20 ​min. The surgical field is cleaned, prepared, and draped hand, which will take 15 ​min. The optimal hemostatic effect of 30 ​min is achieved from the first injection, and the skin incision is made over the previous scar.

Usually, the anatomy is disrupted in these cases where previous surgery produced fibrous tissues and adhesions. It is preferred to start the incision proximal, identify the flexor sheath, FPL, flexor carpi radialis (FCR), and radial artery, and deepen the incision to expose the pronator quadratus (PQ). An additional 5–10 ​ml of WALANT mixture is injected beneath the PQ and around the periosteum. The literature review found that the PQ could not be identified in 44% of cases, and the remaining patients had a thin muscle layer.8 Also, there are circumstances where the screws back out or the plate lifts off from the radius. The rupture of the FPL tendon is seen at the distal edge of the plates, where the frayed ends of the tendon are held in continuity by the pseudo-tendon. The screws and the plate are removed. The FPL tendons and pseudo tendons are debrided. The distal FPL tendon end is identified by extending the same incision over the carpal tunnel and sometimes at the digitopalmar crease. Because of tendon attrition, abrasions, scars, and retraction, the gap between the tendon end is measured. The defect always requires an interposition tendon graft. The normal excursion of the FPL is 5.5–6 ​cm, and the mobility of the muscle belly is checked by its passive stretch. A full IP joint flexion is achieved if there is 3–4 ​cm of passive stretch, and sometimes a 1–1.5 ​cm stretch may result in an adequate IP flexion.

The palmaris longus tendon is harvested by transecting at the volar wrist crease distally and proximally at its musculotendinous junction. The palmaris longus graft is passed through the carpal tunnel and sutured with the distal FPL end by the pulvertaft technique. The proximal portion of the PL is brought to the proximal FPL end, and a single suture is done to assess the tendon tension and get a perfect wrist tenodesis. Next, the tendon tension is adjusted. The pulvertaft technique completes suturing with a slightly more flexed thumb to compensate for the FPL muscle belly contracture and wrist in a neutral position, with the thumb pulp touching the base of the ring finger. The wrist tenodesis and active movement ensure the proper gliding of the PL tendon graft. Active thumb movement is advantageous for WALANT over regional anesthesia. None of the patients required sedation or alternate anesthesia.

2.3

2.3 Postoperative care

A dorsal blocking splint immobilizing the wrist and the thumb in moderate flexion was given. The Kleinert therapy protocol of passive flexion and active thumb extension was started in the first week under the supervision of a hand therapist. Active flexion and extension were started at three weeks, and the brace was continued for up to 6 weeks. The resistive exercises were started eight weeks after surgery. Sports activities were allowed three months after the surgery.

2.4

2.4 Follow-up

The thumb range of motion, pinch, and grip strength was measured using a goniometer and Jamar® Hydraulic Hand Dynamometer (Model J00105) (Sammons Preston, Bolingbrook, Illinois). The Kapandji opposition score assessed the thumb opposition. The pain was on a visual analogue scale (VAS) and functional outcome by the Disabilities of the Arm, Shoulder, and Hand questionnaire (DASH). The patient's experience with the WALANT was also considered comfortable or uncomfortable.

3

3 Statistics

The data were analyzed with CDC epi info software and presented as mean and standard deviation. In addition, the difference between an injured and an uninjured hand was tested with the Wilcoxon Matched Pairs test. Two-tailed p-values of 0.05 or less were considered significant.

4

4 Results

4.1

4.1 Patients and deformity characteristics

Our study's mean age of patients was 52 years (range 45–60 years). There were six male and one female patient (Table 1). The most common presentation was pain (60%), difficulty lifting objects (25%), and using mobile phones (15%). The mean time between surgical fixation and tendon rupture was 1.1 years (range, 6 months −3 years). There was Soong’s grade 1 implant prominence in two patients and grade 2 in five. The mean time between tendon rupture and surgery was 3.1 ​months ​years (range, 2–5 months). The mean defect between the proximal and the distal ends of flexor pollicis longus after debridement of the scarred and ischemic tendon was 5.5 ​cm (range, 5–7 ​cm). The FPL muscle belly (proximal) had an average of 2.5 ​cm passive excursion in our series. None of the patients required sedation or alternate anesthesia.

Table 1 Demographics.
Variables Value
Age (years) 52 (mean)
Gender Male 6
Female 1
Side Right 5
Left 2
Distal radius plates T- Buttress plate 6
Volar locking plate 1
Time interval injury- rupture 1.1 years(mean)

There were no complications at the final follow-up. None of the patients required re-surgery or developed complex regional pain syndrome. All patients were discharged home on the same day. The WALANT provided effective analgesia, and all patients had comfortable experiences. All patients returned to the previous work at the final follow-up.

5

5 Outcomes

The mean follow-up of our study was 16.5 months (range 12–19 months). The IP joint flexion, grip strength, pinch strength, and Kapandji’s score were significantly reduced compared to the unaffected side (p ​< ​0.05) (Table 2). The mean VAS score was 1.5 (range 0–3), and DASH was 14. There were no complications.

Table 2 Statistical analysis.
Outcomes Injured (mean [SD]) Uninjured (mean) P value
Active IP flexion (degrees) 58 (7.3) 77 (2.4) <0.05
Pinch strength (Kg) 6.1(0.2) 8.7 (0.3) <0.05
Grip strength (Kg) 21 (1.2) 32 (1.3) <0.05
Kapandji’s Score 7(0.9) 10 (0) <0.05
6

6 Discussion

The WALANT technique for flexor tendon repair is advantageous over regional or general anesthesia.7,9–12 The awake patient can be educated about the surgery and rehabilitation and can be discharged on the same day. At the same time, the tension of the flexor repair can be adjusted to get perfect wrist tenodesis, and the tendon gap can be sutured to prevent rupture.9–11 The complications of flexor tendon repair, such as adhesions, gapping, and impingement on the pulley, can be effectively addressed in an awake patient by asking to actively move the thumb during the procedure.9–11 The patients can be discharged home on the same day. As a result, the surgery cost is reduced, and the risk of aerosol complications in general anesthesia during Covid-19 is also avoided.12 Though popular, WALANT for flexor tendon repair is done by 10% of American hand surgeons.13

Various studies reported FPL reconstruction following distal radius fractures under (axillary block) or general anesthesia. In their series, the authors utilized an interposition palmaris longus tendon graft, flexor carpi radialis tendon grafts, and IP joint fusion. These studies reported a 73% improvement in thumb movements, 62% in grip strength, and 74% in pinch strength compared with the uninjured hand. The most reported reasons were the suboptimal placement of the plates or screws and FPL tendon attrition. The thumb movements and the functional outcomes did not return to normal after surgery in their series. However, Cho et al.14 reported a case of distal radius fracture fixation with FPL tendon attrition reported 40 months after the surgery. The author performed the primary repair of the FPL tendon and reported a good outcome at six months of follow-up.14

Townsend et al.15 compared the functional outcomes of all flexor tendon repair in fingers between WALANT and traditional anesthesia. There was no statistical difference between the two groups in the age, length, follow-up, proportion of injured digits or zone of injury, range of motion, DASH score, VAS, and rates of tendon adhesions requiring tenolysis. This study did not include FPL rupture following distal radius fracture fixation.

In our series, the thumb range of movements and functional outcomes were not significantly superior to the uninjured hand (p ​< ​0.05). This is quite like previous studies of FPL reconstruction using traditional anesthesia. The possible reasons are FPL tendon attrition, abrasion, and retraction following the rupture. There is no restraint for the FPL rupture at the wrist, and it’s difficult to determine the tendon shortening of the muscle fibrosis preoperatively. The reason for reduced thumb movements in our series is the difficulty in restoring the normal excursion of the thumb with an interposition graft. Also, because of long-standing pathology behind the tendon rupturing, the normal passive stretch of the FPL may not be preserved. The reason for rupture may be multifactorial, but the reconstructive options are limited to free tendon grafts.

The study’s strength is analyzing a series of FPL ruptures following distal radius fracture fixation treated with the WALANT. The study documented that the FPL reconstruction using the WALANT technique is possible, and the plates and screws can be removed simultaneously. All patients were discharged home on the same day and had a comfortable experience. The patients regained pain-free movements in the thumb at the follow-up.

Our study's limitations are the small sample size, retrospective design, and lack of a control group. Since we did not have a comparative study between the WALANT and traditional anesthesia, claiming superiority won’t be easy. However, despite these limitations, our study documented that FPL reconstruction using WALANT achieves a good range of movements, grip and pinch strength, and functional outcome. The outcomes are not significantly better than the uninjured hand because of the inherent long-standing tendon pathological changes. Extensive prospective studies may help evaluate its role and the long-term benefits in this scenario.

Author contribution

TJJ: Roles/writing/review – original draft, literature review, Data curation, Conceptualization, drawing, review & editing.

Registration of research studies

1.Name of the registry: Not applicable.2.Unique identifying number or registration ID: Not applicable.3.Hyperlink to your specific registration (must be publicly accessible and will be checked): Not applicable.

Disclosure of interest

The authors declare that they have no competing interests.

Informed consent

Written informed permission was obtained from the patient(s) for their anonymized information to be published in this article.

Ethical approval

Ethical Committed Board of OHRC Approved. No 15/2023.

Funding

None.

Guarantor

J. Terrence Jose Jerome.

Provenance and peer review

Not commissioned, externally peer-reviewed.

References

  1. , , , , . Flexor pollicis longus tendon ruptures after palmar plate fixation of fractures of the distal radius. J Hand Surg Eur. 2009 Aug;34(4):471-474.
    [Google Scholar]
  2. , , , , , . Flexor tendon rupture after volar plating of distal radius fracture: a systematic review of the literature. Hand Surg Rehabil. 2021 Oct;40(5):535-546.
    [Google Scholar]
  3. , , , , , . Flexor tendon attritional ruptures following distal radius volar plate fixation. J Hand Surg Am. 2023 Jan 10;S0363–5023(22):612-618.
    [Google Scholar]
  4. , , . Flexor pollicis longus tendon rupture after volar wrist plating : reconstruction with palmaris longus interposition graft. Acta Orthop Belg. 2017 Sep;83(3):467-472.
    [Google Scholar]
  5. , , , , et al . Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011;93:328-335.
    [Google Scholar]
  6. , , . Epinephrine in local anesthesia in finger and hand surgery: the case for wide-awake anesthesia. J Am Acad Orthop Surg. 2013;21(8):443-447.
    [Google Scholar]
  7. , , . Tumescent local anesthesia for hand surgery: improved results, cost effectiveness, and wide-awake patient satisfaction. Arch Plast Surg. 2014;41(4):312-316.
    [Google Scholar]
  8. , , , , et al . [Flexor tendon irritations after locked plate fixation of the distal radius with the 3.5 mm T-plate: identification of risk factors] Z für Orthop Unfallchirurgie. 2010;148:319-325.
    [Google Scholar]
  9. , , . Wide-awake flexor tendon repair and early tendon mobilization in zones 1 and 2. Hand Clin. 2013;29:207-213.
    [Google Scholar]
  10. , , , et al . Avoiding flexor tendon repair rupture with intraoperative total active movement examination. Plast Reconstr Surg. 2010;126:941-945.
    [Google Scholar]
  11. , , , . Lessons learned in the authors' first years of wide-awake hand surgery at the W Hospital in Korea. Hand Clin. 2019;35:59-66.
    [Google Scholar]
  12. , , , . Wide-awake local anaesthesia no tourniquet (WALANT) procedures during COVID: a single centre experience. Acta Biomed. 2022 Mar 14;93(1)
    [Google Scholar]
  13. , , , . Current trends in WALANT surgery: a survey of American Society for Surgery of the Hand members. J Hand Surgery Global Online. 2020;2(4):186-190.
    [Google Scholar]
  14. , , , , . Delayed rupture of flexor pollicis longus after volar plating for a distal radius fracture. Clin Orthop Surg. 2012 Dec;4(4):325-328.
    [Google Scholar]
  15. , , , , , , . Functional outcomes of flexor tendon repair in the fingers: a comparison of wide-awake local anesthesia No tourniquet versus traditional anesthesia. Hand 2022 Jan 7
    [Google Scholar]
Show Sections