Case Report
2024
:3;
100352
doi:
10.1016/j.jorep.2024.100352

Translate:

Wide Awake Scapholunate ligament reconstruction

Author affiliations
Ultrasound Guided Hand Surgery and Private Hospital Les Franciscaines, Versailles, France
Exception MD, Montreal, Quebec, Canada
Prince Court Medical Centre, Kuala Lumpur, Malaysia
Article History
Corresponding author(s)

⁎Corresponding author: Thomas Apard. thomasapard@yahoo.fr

Article tools · PDF & citations

Abstract

Abstract

The Dorsal Internal Brace reconstruction is designed to treat scapholunate ligament (SLL) instability. Wide awake surgery without a tourniquet allows the movement of the bones and thus the instability of the carpal bones to be actively visualized during surgery.

The aim of this prospective study is to analyze the feasibility of the Wide Awake Procedure (Walant) for this surgical technique, to assess the stability of the SLL in active motion and then to allow for an early rehabilitation protocol.

From January 2021 to December 2022, 6 adult patients with scapholunate instability stage 3 or 4 according to the Garcia Elias classification were included. Operating under Walant allowed the surgeon to confirm the dynamic instability in active movement per operation and at the end of the procedure to confirm the solidity of the suture without bone impingement. A splint was applied for 3 weeks and then the patients were asked to start rehabilitation.

Osteoporosis in a 60-year-old woman led to failure of the anchor implant. Reconstruction was successful in the other 5 patients. The QuickDASH score decreased from 34 to 9/100. Clinical and radiological examination (X-ray and ultrasound) before surgery and at 6 weeks, 3 months and 6 months postoperatively showed a continued good result.

This preliminary observational report is the first to investigate the feasibility of Walant for SLL repair. We conclude that this technique of anesthesia should be suggested to surgeons to evaluate SLL instability and its treatment.

IV.

Keywords

  • Carpal
  • Walant
  • Internal brace
  • Instability
  • Scapholunate
  • Wrist
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

An isolated injury to the scapholunate ligament (SLL) can lead to abnormal joint mechanics and degenerative cartilage changes in the wrist.1 Treatment of scapholunate instability aims to halt the degenerative process by restoring ligament continuity and normalizing wrist kinematics. Although the SLL is the most commonly injured carpal ligament, treatment remains a challenge.2

The Dorsal Internal Brace® (Arthrex™, France) reconstruction is a new system for open repair of the scapholunate suture.3,4 It appears to stabilize the carpal bones, but surprisingly the surgical technique recommends scaphoid pinning.

As awake surgery allows active per-operative observation of bone movement, we hypothesize that the operator could verify whether surgical carpal reconstruction with this material is effective.5,6

The aim of this prospective, observational, single-center study is to analyze the feasibility of the Walant technique for this surgical procedure and to report on the short-term results of our early active motion protocol.

2

2 Material and methods

From January 2021 to December 2022, we conducted a prospective monocentric study.

All patients were treated conservatively before surgery was proposed with rest, splinting, steroid injection and rehabilitation.

Clinical examination included pain on dorsal scapholunate joint compression and Watson's scaphoid displacement test. Radiological investigations included standard anterio-posterior and lateral radiographs29, dynamic ultrasound of both wrists for comparison, and CT arthrogram (CTA) with arthrography or 3T MRI. We did not perform arthroscopy as the diagnosis of SLL rupture without arthritis was certain.

All patients were classified as 3 or 4 in the Garcia Elias classification.7 We excluded age under 18 years, previous wrist surgery (including arthroscopy or palmar surgery), history of wrist burns, allergy to lidocaine, and patients who refused to participate in this study.

Walant is an acronym for Wide awake, Local Anesthesia and no Tourniquet.5 Wide awake surgery means no sedation, so the patient is not fasting for surgery and has no perfusion. The local anesthesia is a mixture of 40 % lidocaine 1 % with epinephrine, 50 % saline buffered with 10 % bicarbonate 8 %. All procedures were performed without tourniquet. A volume of 60 mL of Walant solution is injected with a 27G needle according to the principles of Joukhadar and Lalonde to minimize pain. No sedation was administered. Fasting was not recommended to avoid fainting.

All 6 patients were operated on by the same surgeon under Walant. The surgical technique was all dorsal, i.e. an isolated V-suture with an internal brace (Arthrex). The approach was dorsal only with an open flap capsulotomy elevated radially. Scapholunate instability was observed with active radial and ulnar deviation and when the patient was asked to make a fist.

Two pins were placed perpendicularly in the scaphoid and lunate to obtain a reduction of the SL gap before drilling two holes in the scaphoid and one hole in the lunate for a V suture. All procedures were performed under fluoroscopy. No tendon graft was used. No posterior interosseous neurectomy was performed.

The patient was asked to move actively after removal of the pins to check the strength of the suture without bone impingement in flexion/extension (Video 1).

A splint immobilized the wrist for 3 weeks. On the 4th week, the patient started physiotherapy with passive and active movements without effort.

Radiological examination (x-ray and ultrasound) was requested at 3 weeks, 6 weeks and 6 months.

3

3 Results

In one patient (60 year old female with a history of osteoporosis), the anchors did not fit into the bone. The surgeon explained the problem to this patient (who was wide awake) and together they decided to change the procedure to a proximal row carpectomy without changing the anesthesia.

In the other 5 patients, the Internal Brace System was effective. The surgeon observed stability of the carpus with no impingement during active motion. In addition, the patient felt the new dynamic of the wrist during movement.

At 3 weeks postoperatively, the splint was removed, and all patients were clean. Rehabilitation was started passively for 3 weeks and actively for the next 6 weeks. At the 6-week and 6-month follow-up, radiographs and ultrasound showed a stable reduction of the scapholunate gap on static and dynamic views.

The results are shown in Table 1. The DASH score decreased from 34 to 9/100 (the first case was excluded).

Table 1 Characteristics of the patients.
age Stage side occupation activities pre op quickDASH perop active deviation perop fist test stable system DASH 6 months remarks
case 1 60 4 right secretary no 38 positive gap failure failure major osteoporosis of carpal bones: CRP
case 2 50 3 left invalidity no 42 positive gap yes 19 CTR same time, Steroid injection at 4 months post operative
case 3 57 4 left businessman biking 19 positive gap yes 5 no
case 4 41 3 right financal ingeneer swimming and tennis 52 positive clunck yes 11 no
case 5 18 3 left student rugby 20 positive gap yes 5 no
case 6 57 3 right businessman tennis 38 positive gap yes 5 no
4

4 Discussion

The diagnosis of a dynamic problem should be analyzed by dynamic and comparative examination, i.e. clinical examination and ultrasonography. We disagree with Cerezal and Roriz8,9 who consider that ultrasound has a limited role in the evaluation of wrist instability. A CT-arthrogram or Magnetic Resonance Imaging confirmed the ligament rupture and all patients had one of these two imaging modalities prior to the outpatient clinic.

We can discuss partial wrist denervation to avoid an intra-articular procedure, but patients refused a temporary solution. Wrist arthroscopy10 Is the gold standard to examine the cartilage and classify the SLL rupture according to the EWAS classification. We could have performed arthroscopy and then an open technique on the same day, but it would have been a very long and complex procedure under WALANT with a large volume of solution.

In our opinion, the Walant technique is the gold standard for objective measurement of carpal instability. Initially developed for soft tissue surgery of the hand,11 Walant is becoming increasingly popular for bone surgery of the hand.12,13 The advantages of walant are the absence of sedative (which causes the higher complication of anesthesia), the absence of tourniquet (which allows hemostasis during surgery and then avoid let-down bleeding when deflating the tourniquet) and the absence of fasting (no fainting, no discontinuation of medications). This technique of anesthesia must be explained to the patient and offered as an alternative technique to an axillary block or general anesthesia (with other advantages and risks). Walant seems to be the perfect technique of anesthesia for dynamic problems in carpal surgery.

Adequate carpal bone density is essential for implantation of the Internal Brace System. Therefore, individuals at high risk for osteoporosis should be aware that if one of the three anchors should fail, another procedure will be selected. Several reconstruction options are available for SLL instability,2,14,15 such as, capsulodesis, bone-ligament-bone graft, or tenodesis. The surgeon must be aware that none of these techniques appear to be possible after attempting to implant the internal construct anchor.

The limitations of our study are the small size of the cohort and the short-term follow-up. The STROBE checklist16 was used in conjunction with this article as a report of a cohort study.

Among the many SLL reconstruction techniques that have been proposed, a clear gold standard is lacking. Therefore, there are still no clinical series of mid- or long-term outcomes after internal fixation reconstruction of SLL. Patient selection for each technique is a key factor for a good outcome. The best reconstruction should consider the stage of SLL instability, respect the proprioceptive nerve supply of the wrist and early active motion.17

This preliminary work concluded the feasibility of dorsal SLL reconstruction under Walant. To our knowledge, this is the first article on total dorsal SLL reconstruction using this technique of anesthesia.18 Larger cohorts and long-term follow-up are needed to validate this technique.

Ethical statement

It is important to lay down standards of expected ethical behaviour by all parties involved in the act of publishing: the authors of this article, the journal editor, the peer reviewer, the publisher and the society for society-owned or sponsored journals.

This includes all parties treating each other with respect and dignity and without discrimination, harassment, bullying or retaliation.

A paper should contain sufficient detail and references to permit others to replicate the work. Fraudulent or knowingly inaccurate statements constitute unethical behaviour and are unacceptable.

Authors may be asked to provide the research data supporting their paper for editorial review and/or to comply with the open data requirements of the journal. Authors should be prepared to provide public access to such data, if practicable, and should be prepared to retain such data for a reasonable number of years after publication.

The authors should ensure that they have written entirely original works.

We agree an author should not in general publish manuscripts describing essentially the same research in more than one journal of primary publication. Submitting the same manuscript to more than one journal concurrently constitutes unethical behaviour and is unacceptable.

The authors did not use generative AI and AI-assisted technologies in the writing process.

No funding statement

This research received no specific grant from any funding agency in the public, commercial, or not-for-profit sectors.

Declaration of patient consent form

The patient's informed consents have be taken and can provided if requested.

CRediT authorship contribution statement

Thomas Apard: Conceptualization, Methodology, Software, Writing – original draft, Supervision, Validation. Jean Paul Brutus: Conceptualization, Visualization, Writing – review & editing, Validation. Amir Adham Ahmad: Visualization, Writing – review & editing, Validation.

References

  1. , . Treatment of scapholunate ligament injury: current concepts. EFORT Open Rev. 2017 Sep 19;2(9):382-393.
    [Google Scholar]
  2. , . Treatment of chronic scapholunate instability according to the functional demand of the wrist. Hand Surg Rehabil. 2023 Mar;31(23)
    [Google Scholar]
  3. , , . Scapholunate ligament internal brace 360-Degree tenodesis (SLITT) procedure. J Wrist Surg. 2018 Sep;7(4):336-340.
    [Google Scholar]
  4. , , , , , , . Internal bracing augmentation for scapholunate interosseous ligament repair: a cadaveric biomechanical study. J Hand Surg Am. 2020 Oct;45(10)
    [Google Scholar]
  5. , . Conceptual origins, current practice, and views of wide awake hand surgery. J Hand Surg Eur. 2017 Nov;42(9):886-895.
    [Google Scholar]
  6. , , , , . Description of WALANT technique in open bone and ligament wrist. Surgery Hand Surg Rehabil.. 2023 Dec;42(6)
    [Google Scholar]
  7. , , , . Three-ligament tenodesis for the treatment of scapholunate dissociation: indications and surgical technique. J Hand Surg Am. 2006;31:125-134.
    [Google Scholar]
  8. , . Ultrasonography for the orthopaedic surgeon. Orthop Traumatol Surg Res. 2019 Feb;105(1S):S7-S14.
    [Google Scholar]
  9. , , . Role of wrist arthroscopy in scapholunate dissociation. Orthop Traumatol Surg Res. 2020 Feb;106(1S):S89-S99.
    [Google Scholar]
  10. , , , , , , . Wide awake local anesthesia no tourniquet (WALANT) versus axillary brachial plexus block for carpal tunnel release in a French public university hospital: care pathways and operating room costs. Orthop Traumatol Surg Res. 2023 May;109(3)
    [Google Scholar]
  11. , , , . The Brazilian perspective of WALANT in fracture fixation from the hand to the elbow. J Hand Surg Glob Online. 2022 Oct 7;4(6):471-476.
    [Google Scholar]
  12. , , , , , . Trapeziometacarpal (TMC) arthroplasty under Wide Awake Local Anesthesia with No Tourniquet (WALANT) versus Local Anesthesia with peripheral nerve blocks (LAPNV): perioperative pain and early functional results in 30 patients. Hand Surg Rehabil. 2021 Sep;40(4):453-457.
    [Google Scholar]
  13. , , , , , . Long-term follow-up of the three-ligament tenodesis for scapholunate ligament lesions: 9-year results. Hand Surg Rehabil. 2021 Sep;40(4):448-452.
    [Google Scholar]
  14. , , , et al . Treatment of chronic scapholunate dissociation with tenodesis: a systematic review. Hand Surg Rehabil. 2018 Apr;37(2):65-76.
    [Google Scholar]
  15. , , , , , , . [The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) statement: guidelines for reporting of observational studies] Internist. 2008 Jun;49(6):688-693.
    [Google Scholar]
  16. , , , . Scapholunate ligament reconstruction without immobilization is safe and leads to better functional results. J Wrist Surg. 2022 Jun 6;12(1):23-27.
    [Google Scholar]
Show Sections