2024
:3;
100249
doi:
10.1016/j.jorep.2023.100249

Translate:

Wrist fusion for multiple failed distal radius fracture fixation and Sauvé Kapandji procedure in the same patient– a case report

Author affiliations
Olympia Hospital & Research Centre, Trichy, Tamilnadu, India
Article History
Article tools · PDF & citations

Abstract

Abstract

Multiple failed distal radius fracture with nonunion and distal radioulnar joint disruption is challenging to treat.

A 54-year-old laborer had multiple failed implant surgeries for his distal radius fractures. He presented with a nonunion distal radius, severe deformity, pain, and median nerve compressive symptoms. The implants were removed, and wrist fusion was done using the resected bones as grafts. The patient remained symptom-free at two years of follow-up.

A wrist fusion is reliable for patients with multiple failed distal radius surgeries and symptomatic nonunion with deformities. The functional and radiological outcome is good, especially for low-demand patients.

Keywords

  • Multiple failed distal radius fractures
  • Implant breaks
  • Nonunion
  • Wrist
  • Fusion
  • Good outcome
Disclaimer:
This article was originally published by Reed Elsevier India Pvt. Ltd. and was migrated to Scientific Scholar after the change of Publisher.
1

1 Introduction

Nonunion of the distal radius fractures is rare, and there is no consensus for treatment.1–4 The etiology is multifactorial. Absence of failure to unite six months after the distal radius fracture is defined as nonunion.1–4 Pain, deformity, stiffness, and median nerve compressive symptoms are seen in nonunions. Radiographs and CT scans assist in planning further treatment in such cases. Previous failed surgeries and implant breaks/failures are common presentations. Surgical modalities to treat nonunion include open reduction, internal fixation and bone grafting, and wrist fusion.1–7 However, the results of these procedures are unpredictable.1–5 Small, osteopenic distal fragments, soft tissue contractures, and atrophic status at the site of delayed healing are the main reasons for this challenging situation.

We report a rare presentation of a 54-year-old man with a distal radius fracture and subsequent two failed surgeries, presenting with a symptomatic nonunion and deformity. Wrist fusion achieved a good functional and radiological outcome.

2

2 Case report

A 54-year-old laborer presented to the clinic with severe deformity, wrist pain, swelling, reduced sensation in the fingers, and restriction of movements in the left wrist (Fig. 1). He was moderately built, a nonsmoker, and non-alcoholic. He fell 18 months back and sustained a distal radius and ulna fracture, for which distal radius plating and distal ulna plating, tension band wiring for the avulsed ulnar styloid process was done elsewhere. Soon for unknown reasons, the distal radius plate was removed three months after the surgery from the same institution (Fig. 2). He presented to another surgeon three months after the second surgery, where an open reduction with a longer distal radius plate, corticocancellous iliac bone grafting, distal ulna plate removal, and Sauve Kapandji procedure (Fig. 3) were done. Six months later, he presented to another clinic with pain, deformity, and numbness in the fingers. Radiographs showed a broken distal radius plate, deformity, and nonunion (Fig. 4).

The clinical picture of a 54-year-old man with (dinner fork) severe deformity, angulation, and multiple previous surgical scars.
Fig. 1 The clinical picture of a 54-year-old man with (dinner fork) severe deformity, angulation, and multiple previous surgical scars.
Anteroposterior and lateral wrist radiographs show atrophic nonunion of the distal radius with derangement of the distal radioulnar joint (DRUJ). There is a shortening of the distal radius and a positive ulnar variance. The distal ulna has a plate and tension band wiring around the ulnar styloid process.
Fig. 2 Anteroposterior and lateral wrist radiographs show atrophic nonunion of the distal radius with derangement of the distal radioulnar joint (DRUJ). There is a shortening of the distal radius and a positive ulnar variance. The distal ulna has a plate and tension band wiring around the ulnar styloid process.
Anteroposterior and lateral wrist radiographs show long radius plating with bone grafts and a Sauve Kapandji procedure for the distal ulna.
Fig. 3 Anteroposterior and lateral wrist radiographs show long radius plating with bone grafts and a Sauve Kapandji procedure for the distal ulna.
Anteroposterior and lateral wrist radiographs show broken distal radius plates and severe angulation and deformity (dinner fork) because of the nonunion and instability.
Fig. 4 Anteroposterior and lateral wrist radiographs show broken distal radius plates and severe angulation and deformity (dinner fork) because of the nonunion and instability.

Physical examination showed a z-deformity in the left wrist and severe angulation in the coronal and sagittal planes (dinner fork deformity). The wrist was stiff, with good movements at the metacarpophalangeal and interphalangeal joints. There was marked shortening of the left radius and sensory loss in the median nerve distribution of the hand. There was no active thumb interphalangeal joint flexion. The hand and pinch grip were 5% compared to the normal side. He reported marked restriction of his profession (tailoring) and daily activities in the left hand. Laboratory results such as complete blood count sugar, thyroid profile, and liver and kidney function tests were normal. The C- reactive protein was 5 mg/L [ normal range 0–5 mg/L]) and erythrocyte sedimentation rate was 10 mm/hour [normal range, 0–15 mm/h]). Multiple previous failed surgeries and available poor bone stock in a laborer with severe dysfunction related the deformity, instability, and pain were the prime considerations in this patient for surgical intervention. The aim was to provide a stable and painless wrist.

Under supraclavicular block, and tourniquet control, the volar aspect of the wrist was opened through the previous scar. There was pseudoarthrosis. The distal end of the proximal fragment and the broken plates were compressing and displaced the median nerve. The rupture of the flexor pollicis longus (FPL) tendon was seen at the broken edge of the plates, where the frayed ends of the tendon are held in continuity by the pseudo-tendon The broken plates and screws were removed. An extended carpal tunnel release decompressed the entrapped and displaced median nerve. The distal radius nonunion site and distal ulna (Sauvé Kapandji procedure) were debrided, and the synovial membrane and avascular bones were excised through a dorsal incision. The screw from the distal ulna was also removed. The articular surfaces from the distal radius and carpal bones were removed. Excising the pseudoarthrosis and freshening the nonunion site of the distal radius created a 3 cm shortening. The distal radius was reduced over the carpal bones and fused with 10-degree dorsiflexion, standard locking compression plates, and screws. The resected bones from the distal radius and the ulna were used as a graft at the fusion area. The FPL tendon was not reconstructed as the patient was not keen on the thumb movement. Postoperatively, the patient was encouraged active finger mobilization and immobilized in a volar wrist splint for six weeks. Splints were removed afterward. The radiographs confirmed the wrist fusion 12 weeks after surgery, and all daily activities were started (Figs. 5 and 6).

Anteroposterior and lateral wrist radiographs show the fusion of the wrist arthrodesis using a standard dorsal tilt LCP plate and screws.
Fig. 5 Anteroposterior and lateral wrist radiographs show the fusion of the wrist arthrodesis using a standard dorsal tilt LCP plate and screws.
The clinical picture shows good alignment and correction of deformity and angulation.
Fig. 6 The clinical picture shows good alignment and correction of deformity and angulation.

The patient was pain-free, and the DASH score was 25 (Video 1). The pinch and the grip strength were 50% better than the preoperative value, and a high degree of patient satisfaction at two years of follow-up. There were no complications or recurrence noted.

Supplementary video related to this article can be found at https://doi.org/10.1016/j.jorep.2023.100249

The following is the supplementary data related to this article:Multimedia component 1Video 1 The preoperative and follow-up videos of the patient.1Multimedia component 1

3

3 Discussion

Various factors contribute to the nonunion of the distal radius. Open fractures, severe comminution, Inadequate immobilization, inadequate fixation, excessive distraction at the fracture site, associated distal ulna fractures, infections, and medical co-morbidities such as diabetes mellitus, hypothyroidism, obesity, smoking/tobacco, and alcohol abuse are some of the factors.1–7 However, nonunion of the distal radius fractures is rare because the fracture gets impacted and is located at the metaphyseal region with less soft tissue disruption. Despite this, Prommersberger and Fernandez1,2 reported 23 distal radius nonunions and found that nine had associated distal ulna fractures. Twenty patients had a previous failed surgery, and over-distraction was the most common reason noted in their study. These authors compared ten patients with nonunion distal radius with distal fragments <5mm of subchondral bone and 13 patients with a larger fragment. The patients with a large distal fragment had nonunion site debridement, corticocancellous iliac bone graft, and stabilization with volar plates. 22/23 patients achieved good bone union and functional outcomes. The patients with small distal fragments (<5mm subchondral bone) had more postoperative complications and Bower's arthroplasty to achieve a fair outcome. None of the patients had multiple successive surgeries or implant failures.

Segalman and Clark5 performed wrist arthrodesis for nonunion distal radius with <5mm subchondral bone and reported success in 5 of the six patients. Smith and Wright6 performed open reduction, bone grafting, and an external fixator and reported good union in 3 of the five patients. Koo and Ho7 performed open reduction and internal fixation with bone graft for a nonunion distal radius in a 75-year-old woman and reported 100 % union and satisfactory functional outcome.

McKee3 reported that metaphyseal distal radius fractures associated with distal ulna shaft fractures (2–3 cm proximal to the ulnar styloid) in elderly patients (average 77 years) are unstable injuries where a closed reduction and cast immobilization are inadequate. Radial deviation of the hand and distal ulna prominence creates a significant deformity. Further, the study noted that these unstable injuries with deformities have distal radius nonunion, and the reason was unclear. McKee documented that closed reduction and case immobilization failed in these unstable injuries, and wrist fusion would be a reliable salvage procedure.3

The author reports a case that started with the nonunion distal radius with an ulnar fracture treated with the distal ulna and distal radius plates and tension band wiring for ulna styloid process avulsion. McKee3 believed the distal ulnar fracture associated with distal radius fractures is unstable. The first surgery overcame this concept by plating the ulna and distal radius. However, the distal radius went into atrophic nonunion. The reason remained unclear. There were no signs of infection. Soon, the distal radius was removed, but the radial deviation, distal ulna prominence, and dinner fork deformity persisted. Therefore, the patient had an open reduction, corticocancellous iliac bone graft, longer distal radius plating, and a Sauvé Kapandji procedure. These procedures were aimed at radius union and deformity correction.

However, the plate broke (failed), and the patient ended with symptomatic nonunion, deformity, instability, atrophic nonunion, and median nerve sensory symptoms. The author could not find specific reasons for all failed attempts to heal. Even though there was >5mm subchondral bone, the author did not prefer open reduction, bone grafting, and fixing the atrophic nonunion. Instead, wrist fusion was considered because of its reliability in achieving union in an unstable wrist with osteopenic bone, deformity, and atrophic status at the previously operated nonunion site.3 The author achieved a stable wrist with a good, fused wrist at the expense of forearm shortening.

The results of open reduction and bone grafting results are not predictable in all cases of distal radius nonunion and implant failures because of poor bone quality, deformities, and instability.3,8 Wrist movements are never restored, and progressive arthritis, tendon adherence, rupture, wound infections, and nonunion can occur.8 Even in the era of the evolution of new implants for distal radius fractures, such as low-profile variable locking and fragment-specific plate fixations, wrist fusion has a reliable role in multiple failed nonunion/implant failed distal radius fractures. In our complex cases, the functional outcome (grip strength, pinch strength) and the radiological union are good after the (single salvage procedure) wrist fusion.

This report does not encourage wrist fusion for all distal radius nonunion and implant failure in the distal radius fractures. Surgeons should always aim for wrist motion in such patients, which enhances strength, the precision of digits, and better hand position in space. With better implants, there is still an appeal and influence for attempting to heal fractures with internal fixation and autogenous cancellous grafts. Sometimes in severe and complex cases, achieving wrist stability at the expense of movements and pain-free must be the goal. The author recommends wrist fusion for exceptional and complex cases, especially for low-demand patients with multiple failures.

4

4 Conclusions

A wrist fusion is reliable for patients with multiple failed distal radius surgeries and symptomatic nonunion with deformities. The functional and radiological outcome is good.

Ethical approval

Ethical approval for this study was obtained from the Ethical Committed Board of OHRC Approved. No 21/2023.

Funding

None.

“Provenance and peer review

Not commissioned, externally peer-reviewed.

Declaration of conflicting interests

The author declares no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Funding statement

The author received no financial support for the research, authorship, and/or publication of this article.

Ethical approval declaration

OHRC Committee or Institutional Review Board provided the approval number as 41/2023.

Informed consent declaration

The patient provided written informed consent for patient information and images to be published.

Guarantor

J. Terrence Jose Jerome.

Declaration of competing interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Informed consent

Written informed consent was obtained from the patient(s) for their anonymized information to be published in this article.

CRediT authorship contribution statement

J. Terrence Jose Jerome: made a substantial contribution to the concept, design of the work, acquisition, analysis and interpretation of data, Drafted the article or revised it critically for important intellectual content, Approved the version to be published, and take public responsibility for appropriate portions of the content.

References

  1. , , , . Surgical management of delayed union and nonunion of distal radius fractures. J Hand Surg. 2001;26A:201e9.
    [Google Scholar]
  2. , , . Non-union of distal radius fractures. Clin Orthop. 2004;419:51-56.
    [Google Scholar]
  3. , , . Non-union of distal radial fractures associated with distal ulnar shaft fractures: a report of four cases. J Orthop Trauma. 1997;11:49-53.
    [Google Scholar]
  4. , , . Nonunion of the distal radius. Tech Hand Up Extrem Surg. 2002;6:6-9.
    [Google Scholar]
  5. , , . Un-united fractures of the distal radius: a report of 12 cases. J Hand Surg. 1998;23A:914-919.
    [Google Scholar]
  6. , , . Nonunion of the distal radius. J Hand Surg. 1999;24B:601-604.
    [Google Scholar]
  7. , , . Non-union of fracture of distal radius: a case report and literature review. Journal of Orthopaedics, Trauma and Rehabilitation. 2011;15(Issue 1):21-24.
    [Google Scholar]
  8. , , . Nonunion of the distal radius. Tech Hand Up Extrem Surg. 2002;6:6-9.
    [Google Scholar]